Renovation of an elderly care / assisted living facility in Corpus Christi, Texas. Completed plans call for the renovation of a elderly care / assisted living facility.

**As of August 30, 2021, project was awarded to Jugany Group, Inc. for $79461.14. HHSC PCS is seeking competitive bids to establish Contract(s) for construction and repairs for ten (10) buildings at the Corpus Christi State Supported Living Center (CCSSLC) in order to remediate Life Safety Code (LSC) deficiencies related to fire safety and fire and smoke barrier walls. Any contract resulting from this Solicitation will have a term beginning 09-01-2021 and expiring 08-31-2022. Questions or Clarifications - Addendum Posted on the ESBD extension to Wednesday, August 11, 2021, 5:00 PM Central Time and Response Deadline extension to Monday, August 16, 2021, 10:30 AM Central Time Anticipated Contract Start Date September 1, 2021 The PCS sole point of contact for inquiries concerning this Solicitation is: Susan Mullan, CTCD 512-406-2575 Susan.mullan@hhs.texas.gov The Contractor is required to provide current copies of the completed training(s) and of the license or accreditation certificate related to the training upon request by the HHS Agency contract manager. This requirement applies to Subcontractor(s) and Subcontractor's personnel who may be used in the performance of services. HHSC maintains the right to reject any or all Responses and to cancel this Solicitation if HHSC, in its sole discretion, considers it to be in the best interests of HHSC to do so. *The list of planholders and/or interested bidders is not being tracked by the stakeholders involved with this project. If you are an interested contractor and wish to be listed as a bidder, please notify our editorial staff at addtobidlist@constructconnect.com. The description of requirements, services, specifications for goods which may be required, and deliverables as provided in this Solicitation and any resulting Contract which the Contractor is required to provide. 1. Building 503: Contractor shall provide labor and materials to repair fire barrier walls that have a one (1) hour fire resistance rating to resist the passage of smoke for approximately forty-five (45) feet of wall in the mechanical room of Building 503. Contractor shall remove ceiling tiles and grids to access areas to be fire protected. Contractor shall install fire resistant caulking to ensure the designated areas meet fire rating state inspection requirements. 2. Building 504: Contractor shall provide labor and materials including but not limited to fire caulking, sheetrock, and all ceiling tiles and grids that could sustain damage during the provision of services. Contractor shall construct and/or repair fire barrier walls that have a one (1) hour fire resistance rating to resist the passage of smoke for approximately thirty-nine (39) feet of wall in the mechanical room and sixty (60) feet of wall in the workshop room in Building 504. Contractor shall remove ceiling tiles and grids to access areas to be fire protected. Contractor shall install fire caulking and sheetrock in order to ensure the designated areas meet fire rating state inspection requirements. 3. Building 514: Contractor shall provide labor and materials to repair smoke barrier walls that have a one (1) hour fire resistance rating to resist the passage of smoke for approximately thirty-three (33) feet of wall in the mechanical room of Building 514. Contractor shall remove ceiling tiles and grids to access areas to be fire protected. Install fire resistant caulking to ensure that the designated areas meet fire rating state inspection requirements. 4. Building 518: Contractor shall provide labor and materials to repair smoke barrier walls that have a one (1) hour fire resistance rating to resist the passage of smoke for approximately thirty (30) feet of wall in the mechanical room of Building 518. Contractor shall remove ceiling tiles and grids to access areas to be fire protected. Install fire resistant caulking to ensure that the designated areas meet fire rating state inspection requirements. 5. Building 506: Contractor shall provide labor and materials including but not limited to fire caulking, sheetrock, and all ceiling tiles and grids that could sustain damage during the provision of services. Contractor shall construct and/or repair fire barrier walls that have a one (1) hour fire resistance rating to resist the passage of smoke for approximately forty-eight (48) feet of wall in the mechanical room in Building 506. Contractor shall remove ceiling tiles and grids to access areas to be fire protected. Contractor shall install fire caulking and sheetrock in order to ensure the designated areas meet fire rating state inspection requirements. 6. Building 523: Contractor shall provide labor and materials including but not limited to fire caulking, sheetrock, and all ceiling tiles and grids that could sustain damage during the provision of services. Contractor shall construct and/or repair fire barrier walls that have a one (1) hour fire resistance rating to resist the passage of smoke for approximately twenty-three (23) feet of wall in the storage room and one-hundred and two (102) feet of wall in the hazard room in Building 523. Contractor shall also construct and/or repair fire barrier walls that have a one-half (1/2) hour fire resistance rating to resist the passage of smoke for approximately forty-eight (48) feet of wall that separates the workshop area from the housekeeping side of building 523. Contractor shall remove ceiling tiles and grids to access areas to be fire protected. Contractor shall install fire caulking and sheetrock in order to ensure the designated areas meet fire rating state inspection requirements. 7. Building 522: Contractor shall provide labor and materials including but not limited to fire caulking, sheetrock, and any and all ceiling tiles and grids that could sustain damage during the provision of services. Contractor shall construct and/or repair fire barrier walls that have a one-half (1/2) hour fire resistance rating to resist the passage of smoke to resist the passage of smoke for approximately two-hundred and thirty one (231) feet of wall located along the residential areas in Building 522. Contractor shall remove ceiling tiles and grids to access areas to be fire protected. Contractor shall install fire caulking and sheetrock in order to ensure the designated areas meet fire rating state inspection requirements. 8. Building 524: Contractor shall provide labor and materials including but not limited to fire caulking, sheetrock, and any and all ceiling tiles and grids that could sustain damage during the provision of services. Contractor shall construct and/or repair fire barrier walls that have a one-half (1/2) hour fire resistance rating to resist the passage of smoke for approximately sixty-six (66) feet of wall located along the residential areas in Building 524. Contractor shall remove ceiling tiles and grids to access areas to be fire protected. Contractor shall install fire caulking and sheetrock in order to ensure the designated areas meet fire rating state inspection requirements. 9. Buildings 515, 516: Contractor shall provide labor and materials including but not limited to fire caulking, sheetrock, and any and all ceiling tiles and grids that could sustain damage during the provision of services. Contractor shall construct and/or repair fire barrier walls that have a one-half (1/2) hour fire resistance rating to resist the passage of smoke for approximately thirty-three (33) feet of wall located between Building 515 and Building 516 dining room. Contractor shall remove ceiling tiles and grids to access areas to be fire protected. Contractor shall install fire caulking and sheetrock in order to ensure the designated areas meet fire rating state inspection requirements.

Award

Elderly Care / Assisted Living

$79,461.00

Public - State/Provincial

Renovation

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

7

Subscribe For Documents

4 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
12
Active Projects
7
Bidding Soon
210
All Active Projects
90
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

August 16, 2021

September 1, 2021

img_map_placeholder

902 Airport Rd, Corpus Christi, TX


The data you need to build the relationships you want. Try it free.

Access Now

Get the right
data with Project Intelligence

Share with your network.

Project Shared

with

example@example.com

Upgrade now for industry‑leading commercial construction data.

You've reached the free-view limit.

Thousands of projects are added every week - don't miss out. Explore the best product options for your business and subscribe today.

Get Access Now

Choose what you would like to do.

Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.