BLOCK PAGE!!!
Get Full Details

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Published January 20, 2022 at 7:00 PM

Updated November 15, 2023

Renovation of a mixed-use development in Tucson, Arizona. Completed plans call for the renovation of a educational facility.

The design-build contractor shall provide all the necessary engineering material procurement, management, labor, materials, tools, equipment, supplies, services, components, and disposal and comply with the contract's general conditions to successfully complete the replacement of existing HVAC unit scope of work to the satisfaction of the owner. This project is funded by ESSER and must Comply with Davis/bacon wages, and emphasizes energy saving. All replacement units shall meet the minimum efficiency requirements shown in the specifications Procure and install new like -for- like most highly efficient units (SEER's) available, based on Tonnage. Contractor shall ensure All Bipolar Ionization units are removed from old units, reinstalled on new units and are in working condition. Particle testing and assurance are required. Procure and install new supply fan variable speed drive Proposed/installed unit weight shall not exceed 5% above existing HVAC unit weight Reuse existing curbs on the roof provide curb adapter if necessary Install new disconnect switch and conduit to the new units ducting and air distribution Re-use existing ductwork Test and balance all modified systems Preform duct leak remediation as required compliance with 2016 title 24 standards and regulations, section 110 (or prevailing title 24) controls Install smoke detector and connect to existing thermostat and /or controls. Only where needed for compatibility, update thermostat commissioning Commission equipment and controls Commission outside air economizer consistent with 2016 title 24 code requirements for ventilation (or prevailing title 24). Document and submit commissioning log for all equipment as outlined in appendix A to the scope of work As needed, install smoke detector and connect to existing fire alarm systems as required *This project has been identified as part of a stimulus package

Award

Educational

$4,918,439.00

Public - City

Renovation

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

Subscribe For Documents

13 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
17
Active Projects
2
Bidding Soon
172
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

November 12, 2021

December 13, 2021

Project location map

Multiple Locations, Tucson, AZ

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.