Site work for a water / sewer project in Parsippany, New Jersey. Completed plans call for site work for a water / sewer project.

This project includes the following upgrades: Base Bid: I. Redevelopment of Well 3. Refurbish Discharge Head; Replacement of Vertical Line Shaft Motor, 25 Hp, Vertical Line Shaft Pump Bowl Assembly, Stuffing Box, Line Shafts and Spiders; Replacement of Column Pipe, Airline, Water-level Access Drop Pipe, and Water-Level Direct Read Gauge; Replacement of two (2) Gate Valves, one (1) combination air-release/vacuum valve, and one (1) Check Valve; Replacement of one (1) Chlorine Injection Pump; Replacement of one (1) Venturi Flow Meter; Replacement of one (1) flow transmitter; and Inspect and Replace one (1) wellhead base plate. II. Redevelopment of Well 10. Refurbish Discharge Head; Inspect Motor; Inspect and Replace Vertical Line Shaft Pump Bowl Assembly (if required), Stuffing Box, Line Shafts and Spiders; Replacement of Column Pipe, Airline, Water-Level Access Drop Pipe, and Water-Level Direct Read Gauge; Replacement of one (1) Gate Valve, one (1) combination air-release/vacuum valve, and one (1) Check Valve; and Inspect and Replace one (1) wellhead baseplate. III. Redevelopment of Well 4. Refurbish Discharge Head; Inspect Motor; Inspect and Replace Vertical Line Shaft Pump (if required), Stuffing Box, Line Shafts and Spiders; Replacement of Column Pipe, Airline, Water-Level Access Drop Pipe, and Water-Level Direct Read Gauge; Replacement of one (1) combination air-release/vacuum valve, and one (1) Surge Release Valve; and Inspect and Replace one (1) wellhead baseplate. IV. Redevelopment of Well 4A. Refurbish Discharge Head; Inspect Motor; Inspect and Replace Vertical Line Shaft Pump (if required), Stuffing Box, Line Shafts and Spiders; Replacement of Column Pipe, Airline, Water-Level Access Drop Pipe, and Water-Level Direct Read Gauge; Replacement of one (1) combination air-release/vacuum valve; and Inspect and Replace one (1) wellhead baseplate A certified check or cashier's check made payable to the Township of Parsippany-Troy Hills, or a duly executed bid bond in the amount of 10% of each bid, but in no case in excess of $20,000.00, must be deposited by the bidder together with a Certificate of Surety evidencing that he can obtain the required Performance Bond and Payment Bond in the amount of one hundred percent (100%) of the total amount of the contract. The successful bidder shall be required to deliver to the Township an executed Performance Bond of the responsible indemnity company authorized to do business in the State of New Jersey. In lieu of a Certificate of Surety, the bidder may submit, at the bid opening, a certified check or cashier's check in the amount of one hundred percent (100%) of the total amount of the bid. Bidders are required to comply with requirements of N.J.S.A. 10:5-31 et seq and N.J.A.C. 17:27. In addition bidders must also comply with the following New Jersey Statutes: Section 1 of P.L.1977, c.33 Statement of Ownership (N.J.S.A. C.52:25-24.2) N.J.S.A. 40A:11-18 American Goods and Products to be Used Where Possible Section 21 of P.L.1971, c.198 Guarantee to be Furnished with Bid (N.J.S.A. C.40A:11-21) Section 22 of P.L.1971, c.198 Surety Company Certificate (N.J.S.A. C.40A:11-22) Section 16 of P.L.1971, c.198 Listing of Subcontractors (N.J.S.A. C.40A:11-16) Section 1 of P.L.2001, c.134 Business Registration (N.J.S.A. C.52:32-44) N.J.S.A. 34:11-56.25 et seq N.J. Prevailing Wage Act All Bidders and their Subcontractors must comply with the requirements of the New Jersey Public Works Contractor Registration Act, N.J.S.A. 34:11-56.48 et seq. Section 017300, The Township of Parsippany Troy Hills reserves the right to reject any and all bids or to waive any minor informalities or irregularities in the proposal received and to accept the bid which is in the best interests of the Township. The Township further reserves the right to consider all bids for sixty (60) days after the bid opening before awarding a contract. AC schultes - Well 3 - $ 149,590 Well 10 - $ 155,255 Well 4 - $ 157,480 4A - $ 102,245

Bid Results

Water / Sewer

$564,570.00

Public - City

Site Work

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

Subscribe For Documents

2 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
433
Active Projects
192
Bidding Soon
4,503
All Active Projects
1,997
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

May 19, 2022

June 20, 2022

img_map_placeholder

Multiple Locations, Parsippany, NJ

Related To This Project


The data you need to build the relationships you want. Try it free.

Access Now

Get the right
data with Project Intelligence

Share with your network.

Project Shared

with

example@example.com

Upgrade now for industry‑leading commercial construction data.

You've reached the free-view limit.

Thousands of projects are added every week - don't miss out. Explore the best product options for your business and subscribe today.

Get Access Now

Choose what you would like to do.

Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.