Privately Funded
Bidding Soon
Documents Available
Publicly Funded
Addenda Available
Post-Bid
Saving Project...
Renovation of a water / sewer project in Westover, Maryland. Completed plans call for the renovation of a water / sewer project.
The Maryland Environmental Service is soliciting competitive sealed bids from qualified Contractors to provide a specialized company, referred to as Membrane Installer Company (MIC) to remove the old elements, prepare and clean the vessels and install new RO elements, all with their own or haired staff. Located at the Eastern Correctional Institution Water Treatment Plant located at 30420 Revells Neck Rd, Westover, Maryland 2189. Go to MES Procurement Portal Bonfire website. - General A. Maryland Environmental Service (MES) operates 2.0 MGD RO plant located at the Eastern Correctional Institution Water Treatment Plant located at 30420 Revells Neck Rd, Westover, Maryland 2189. The project was designed by WATEK Engineering Corporation. B. After over 11 years of successful operation, MES operations have decided to replace the RO elements for reduction in power consumption and preparing the facility for many more years of successful operation. Clean in Place (CIP) was performed for Skid A about 3 years ago. CIP was not necessary for the other two skids (Skids B and C) in 11.5 years of operation. C. Pretreatment consists of 5 micron cartridge filters and Avista Vitec 8200 fed at 2 mg/L. D. MES is solicitating bids for a specialized company, referred to as Membrane Installer Company (MIC) to remove the old RO elements, prepare and clean the vessels and install new RO elements, all with their own or hired staff. E. MES have very limited staff managing multiple facilities and cannot assist in the installation. However, they will assist with any reasonable operational changes to accommodate this project. MES may also have part time operators to witness the installation, as training. F. WATEK Engineering staff will witness key installation phases and will witness profiling and testing. G. The current RO skid capacity, size and design parameters are shown in the table below. RO feed flow/skid 385 gpm Permeate capacity/skid 308 gpm Raw water bypass for blending/skid 120-200 gpm Number of RO skids 3 Stages 2 Array (2:1), Pressure Vessels (PV) 10 (1st), 5 (2nd) First Stage Two columns of 5 PV Second Stage One column of 5 PV Design RO Skid Recovery 82.0% Membrane diameter (standard) 8-inch Membrane length (standard) 40-inch Membrane area (standard) 400 sq. ft Pressure vessel length 6 elements long Number of vessel positions vertically 5 Number of vessel positions horizontally 3 Total number of RO elements in facility 270 Maximum Skid Average Permeate Flux 12.5 GFD A. RO Membrane Elements 1. The membrane elements shall be thin film composite Reverse Osmosis membranes with 400 square feet of nominal active membrane surface area in a standard 8-inch 40-inch spiral wound configuration. 2. Minimum performance required: Salt Rejection 99.65 % Permeate Flow 8,900 gpd 3. Provide projections and documentation to certify the above performance requirements. 4. The operating characteristics of the membrane elements shall be measured at the following conditions: Test solution 2000 mg/l, NaCl solution Applied pressure 225 psi Test temperature 25 degrees C Element recovery 15% pH 8 5. The membranes shall be individually tested and permanently marked with a factory serial number. Test conditions shall be as on the membrane data sheet submitted with bid. A test report shall be submitted to the Engineer prior to membrane shipment. The test report shall provide for each element, the following: Membrane Serial Number Date of Test Test conditions: temperature, pressure, feed water composition, recovery, meeting performance requirements specified. Test results: Rejection, Characteristic membrane productivity in gpd, meeting performance requirements specified. 6. Only new membranes shall be provided. "Patched" new membranes, or membranes that have been reconditioned, or refurbished, will not be accepted. 7. RO Membrane Element: Toray TM 720D-400. Due to excellent performance from these membranes, MES and WATEK intend to replace with the same type of elements.
Bid Results
Water / Sewer
$156,836.00
Public - State/Provincial
Renovation
Trades Specified
Division 00 - Lorem Ipsum
One Low Price
- One license and one market
- Details and key contacts on all bidding projects
- Organize your pipeline with a digital bid board
- Automatically match opportunities to your profile
- Saved searches deliver daily project leads to your email inbox
Market Pricing Around
- All Starter Product functionality
- Access to all documents (plans, specifications, and addenda)
- Access to planning projects
- Access to contact information
- Ability to Export
Find More Local Projects
Within 75 Miles of This Project
You’ve Reached the Free View Limit
Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.
Come back in [[refresh_days]] to get [[project_count]] more free projects.
June 21, 2022
July 21, 2022
30420 Revells Neck Rd, Westover, MD
Related To This Project
Westover, MD
Bid Date: Jun 29 2022
Westover, MD
Bid Date: Jul 28 2022
Westover, MD
Bid Date: Jul 29 2022
Westover, MD
Bid Date: Mar 30 2023
Westover, MD
Bid Date: May 11 2023
Westover, MD
Bid Date: Jul 13 2023
Westover, MD
Bid Date: Jul 13 2023
Westover, MD
Bid Date: Aug 22 2023
Westover, MD
Bid Date: Apr 13 2022
Westover, MD
Bid Date: Mar 28 2022
Westover, MD
Bid Date: Dec 14 2022
Westover, MD
Bid Date: Nov 29 2022
Recently Viewed
--
--
--
--
--
--
--
--
--
--
The data you need to build the relationships you want. Try it free.
Sign up now to get free company and project data. No payment required.
Get the right
data with Project Intelligence
Project Shared
with
example@example.com
Choose what you would like to do.
Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.
What is your business type?
We have a wide variety of products that are purpose built for certain business types.