Privately Funded
Bidding Soon
Documents Available
Publicly Funded
Addenda Available
Post-Bid
Saving Project...
Renovation of a mixed-use development in New York, New York. Conceptual plans call for the renovation of a medical facility.
LOCATION James J. Peters DVA Medical Center, 130 W. Kingsbridge Road, Bronx, NY 10468 COST RANGE Estimated Construction Costs are Between $2,000,000 and $5,000,000. TYPE OF CONTRACT CONTEMPLATED The Department of Veterans Affairs is contemplating awarding a firm fixed price contract. FEASIBILITY STUDY COMPLETION PERIOD: The Department of Veterans Affairs requires complete feasibility studies as indicated in SOW above. The A/E shall deliver a complete design __180__ calendar days from the Notice to Proceed (NTP). THIS ANNOUNCEMENT IS NOT A REQUEST FOR PROPOSAL. THE GOVERNMENT WILL NOT PAY NOR REIMBURSE ANY COSTS ASSOCIATED WITH RESPONDING TO THIS REQUEST. THE GOVERNMENT IS UNDER NO OBLIGATION TO AWARD A CONTRACT AS A RESULT OF THIS ANNOUNCEMENT. The Department of Veterans Affairs is seeking a qualified Architect-Engineering (AE) firm to provide design services for Project 526-20-121 Upgrade Security Systems at the James J. Peters DVA Medical Center located at 130 W. Kingsbridge Road, Bronx, New York 10468. This Project will provide design services that will include demolition of existing systems, Architectural, Environmental, HVAC, Plumbing, Mechanical, Electrical, Fire/Life Safety, Controls, Communication, and security impacts that conform to the most updated VA Security Systems Design Guide in order to upgrade the existing Medical Center security and camera systems. This requirement is being procured in accordance with the Brooks Act as implemented in FAR Subpart 36.6. Applicable NAICS code is 541330 and small business size standard of $16.5 Million. Since this is a feasibility study, a construction estimate is not applicable for this procurement. This is a 100% Service-Disabled Veteran Owned Small Business Set Aside. The anticipated award date of the proposed A-E Contract is on or before (November 30, 2022). Potential contractors must be registered in SAM (www.sam.gov ) and are visible/verified/certified as SDVOSB in VetBiz (https://www.vetbiz.va.gov/ ) at time of submission of their qualifications in order to be considered for an award. In order to assure compliance with FAR Clauses, 852.219-74 Limitations on Subcontracting (JUL 2018)(DEVIATION) and VAAR 852.219-10, VA Notice of Total Service-Disabled Veteran-Owned Small Business Set-Aside (NOV 2020) (DEVIATION), all firms submitting a SF 330 for this notice are required to indicate what percentage of the cost of contract performance will be expended on the concerns employees and in which discipline(s) and percentage of cost of contract performance to be expended (and in what disciplines) by any other consultant/subcontractor or otherwise used small or large business entity(s). Any consultant/subcontractor or otherwise business entity(s) used must be identified by name, office location and size/type of business (i.e., SDVOSB, VOSB, 8(a), small, large, etc.). Failure to provide this information will deem the firm's SF 330 submittal as nonresponsive and preclude further evaluation All A/E firms are advised that in accordance with VAAR 836.606-71 the total cost of the production and delivery of designs, plans, drawings and specifications shall not exceed 6 percent of the estimate cost of construction. Other A-E fees are not included in this 6 percent. Additionally, FAR Clause 52.236-22 (c) - Design Within Funding Limitation, will be applicable to this procurement action. SCOPE OF SERVICE REQUIRED Upgrade Security Systems Project 526-20-121 ARCHITECT / ENGINEERING SERVICES 1. GENERAL SCOPE This is a design contract for the James J. Peters Veterans Affairs Medical Center (JJP VAMC), 130 West Kingsbridge Road, Bronx, New York 10468 to provide professional architect - engineer (A/E) services to design a new security system throughout all facilities on the JJP VAMC campus to facilitate award of a construction contract. A/E services to include but are not limited to Demolition, Architectural, Environmental, HVAC, Plumbing, Mechanical, Electrical, Sprinkler, Fire/Life Safety, Controls and Communication, as well as other design considerations. The final design approval shall be at the determination of the JJP VAMC Engineering Services. The design intent is to replace the existing security system with the latest technology in video surveillance and access control capabilities. The JJP VAMC campus includes over one million square feet of interior space. There are a total of 8 main facilities (the largest being the main hospital) and a few smaller / temporary buildings such as a guard shack and office trailer. The campus perimeter is surrounded by an existing security fence covering over 27 acres of property. The A/E shall design a new security system and include the removal of the existing system. The new security system design will include the following components: internet protocol cameras (IP), network video recording (NVR), access control system, upgrades to the video surveillance rooms, motion detected intrusion alarm system, electronic entrance and exit drive / walk gates, electronic parking barriers, and security fencing. All components specified must be VA approved manufacturers (must not be made in China) and no devices / associated components are to be made wireless due to security concerns. In addition, the new security system design must be "open architecture" without any proprietary constraints and all administrative codes for software shall be given to the VA. The existing security system primarily utilizes analog cameras with digital video recording (DVR). There are currently an estimated 476 cameras. Cameras will be updated to an IP camera infrastructure. This includes a range of camera capabilities such as thermal imaging and motion detection. The new network cameras must remain separate from the existing IT network. The access control system will include PIV access to an estimated 200 doors throughout the campus, drive / walk gates, and associated components such as long-range barcode readers and windshield tags to support the parking plan. The design will include a total of five (5) electronic parking road barriers. The surrounding area will include a commercial grade security fence estimated to be 200 linear feet by 6 ft tall. The video surveillance rooms require new high-definition televisions and workstations to power the video monitors and display the video feeds. Appropriate signage shall be included, and all work will require new runs of cable. The demolition of the existing security system shall include all cables and electronic devices and fixtures. The existing security system must remain operational during construction. The design should implement phasing if necessary. Existing conditions must be verified by the A/E for all design considerations. The design shall modify any existing layout and equipment to provide adequate security coverage throughout the campus. This includes incorporating the current and future construction plans into the final design. The A/E shall provide a commissioning and training plan for the new security system. The A/E approved competent person shall be responsible for testing and providing the results to the VA assigned COR. In addition, the A/E approved competent person shall conduct on-site training for VA end users for operation and maintenance of the security system and shall provide both a written and video training plan. Training shall be conducted after final commissioning is completed and before transitioning from the existing security system to the new. Deliverables for A/E Technical Proposal: 1.) SF330 submission following the SF330 section order. If the A/E cannot comply with the SP-13 schedule, then a revised SP-13 with new proposed design submission dates shall be submitted to the Contracting Officer to be reviewed. Attachments: A: SP-13 Design Schedule Security System Reference: A: PG-18-13 (VA BIM & CAD Standards) The method of contractor selection has not been determined at this time. *The value for this project is based on a financial range. The value is listed as the highest possible cost from the range provided by a stakeholder or official project document.
Conceptual
Medical
$5,000,000.00
Public - Federal
Renovation
Trades Specified
Division 00 - Lorem Ipsum
Find More Local Projects
Within 75 Miles of This Project
One Low Price
- One license and one market
- Details and key contacts on all bidding projects
- Organize your pipeline with a digital bid board
- Automatically match opportunities to your profile
- Saved searches deliver daily project leads to your email inbox
Market Pricing Around
- All Starter Product functionality
- Access to all documents (plans, specifications, and addenda)
- Access to planning projects
- Access to contact information
- Ability to Export
You’ve Reached the Free View Limit
Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.
Come back in [[refresh_days]] to get [[project_count]] more free projects.
August 25, 2023
130 W Kingsbridge Rd, New York, NY
Related To This Project
New York, NY
Bid Date: Aug 09 2022
New York, NY
--
New York, NY
Bid Date: Oct 26 2021
New York, NY
Bid Date: May 03 2022
New York, NY
--
New York, NY
--
New York, NY
--
New York, NY
Bid Date: Aug 09 2022
New York, NY
Bid Date: Aug 09 2022
New York, NY
Bid Date: Aug 09 2022
New York, NY
Bid Date: Aug 09 2022
New York, NY
Bid Date: Aug 09 2022
New York, NY
Bid Date: Aug 09 2022
New York, NY
--
Recently Viewed
--
--
--
--
--
--
--
--
--
--
The data you need to build the relationships you want. Try it free.
Sign up now to get free company and project data. No payment required.
Get the right
data with Project Intelligence
Project Shared
with
example@example.com
Choose what you would like to do.
Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.
What is your business type?
We have a wide variety of products that are purpose built for certain business types.