Privately Funded
Bidding Soon
Documents Available
Publicly Funded
Addenda Available
Post-Bid
Saving Project...
Renovation of a mixed-use development in Cherry Hill, New Jersey. Completed plans call for the renovation of a educational facility.
Cherry Hill East High School 2023 Partial Roof Replacement, J.F. Cooper Elementary School 2023 Partial Roof Restoration, A. Russell Knight Elementary School 2023 Partial Roof Restoration and Joseph D. Sharp Elementary School 2023 Partial Roof Restoration. Bids shall be address to the Owner whose name appears in Paragraph 1a of the Instructions to Bidders; they shall be mailed or delivered to the address stated herein, enclosed in an opaque sealed envelope, clearly marked with the name of the Bidder and the name of the Project and the Bid# as described in the Notice to Bidders; and must be received by not later than the time designated in this Notice to Bidders. No responsibility will attach to Architect or Owner for premature opening of a bid which not properly identified. The Bidders shall submit, in accordance with N.J.S.A. 18A:18A-18(b)(2), one Lump Sum Bid for all the work and materials. Bidders must be pre-qualified by the New Jersey Department of Treasury, Division of Property Management and Construction (DPMC) with at least the DPMC classification associated w the work they intend to directly perform or, if Bidder will not directly perform any work, with DPM classification C006, C008, or (if the project does not call for construction of a new facility) C009. Bidders' Prime Subcontractors must be pre-qualified by DPMC with the DPMC classification associated with the work they intend to directly perform or subcontract. The Bidder and named Prime Subcontractors, defined as those listed in N.J.S.A. 18A:18A-18, listed must be pre-qualified prior to the date that bids are received. Bids must be accompanied by a certified check bank cashier's check, treasurer's check or Bid Bond in the form provided in the Contract Document with corporate surety satisfactory to the Owner, in an amount of 10% of the Base Bid (but in no case in excess of $20,000.00, pursuant to N.J.S.A. 18A:18A-24), naming as payee or oblige, as applicable, Cherry Hill Board of Education, to be retained and applied by the undersigned as provided in the Contract Documents in case the successful Bidder defaults in executing the Agreement or furnishing the bonds and insurance certificates as required by the Contract Documents. Prospective Bidders are advised that this Project is one which will be subject to and be governed by provisions of New Jersey law, including, but not limited to, those regarding (a) Prequalification of Bidders (N.J.S.A. 18A:18A-26 et seq.); (b) Prevailing Wage Rates (N.J.S.A. 34:11-56.25 et seq.); (c) Use of Domestic Materials, (N.J.S.A. 18A:18A-20) (d) Ownership Disclosure Certification, (N.J.S.A. 52:25-24.2); and (e) disclosure of investment activities in Iran Russia, and Belarus (N.J.S.A. 18A:18A-49.4 et seq. & N.J.S.A. 52:32-55 et seq.). The Public Work Contractor Registration Act N.J.S.A. 34:11-56.48 et seq. requires that the Bidder and Named Prim Subcontractors must be registered at the time of Bid. The Owner is requesting that copies of the Certificates for Bidder and its Named Prime Subcontractors be included in the Bidder's Bid Package but the Bidder must provide copies of the Certificates no later than the time of award. Pursuant t N.J.S.A. 52:32-44 all business organizations that do business with a local contracting agency, including Bidders and Named Prime Subcontractors, are required to be registered with the State through the New Jersey Department of Treasury, Division of Revenue. The Owner is requesting th Bidder's Bid Package, but the Bidder must provide proof of such Registrations prior to the award the Contract. In addition, each bid must be accompanied by a certificate from a surety company stating it will provide said Bidder with a bond in such sum as required by the N.J.S.A. 18A:18A-2 No bid may be withdrawn for a period of sixty (60) days after the dates set for the opening there The right is reserved to reject all bids pursuant to N.J.S.A. 18A:18A-22 or to waive minor informalities, defects, and non-material exceptions. Bidders are required to comply with the provisions of N.J.S.A. 10:5-31 et seq. and N.J.A.C. 17:27-1.1 et seq. Prospective bidders are advised that the Project is subject to a Project Labor Agreement (PLA). The successful bidder and subcontractors (of any tier) will be bound by the terms and conditions of the PLA. After award an prior to commencement of the work, the successful bidder and its subcontractors (of any tier) m also execute the Letter of Assent in the form provided. Friday 02/10/23 Deadline for Questions at 5:00 P.M. (email to jangelo@garrisonarch.com) BUDGET $6,900,000.00 2023 PARTIAL ROOF RESTORATION at the A. RUSSELL KNIGHT ELEMENTARY SCHOOL 140 OLD CARRIAGE ROAD CHERRY HILL, NEW JERSEY 08034 GA<<22-87K. 2023 PARTIAL ROOF REPLACEMENT at the CHERRY HILL EAST HIGH SCHOOL 1750 KRESSON ROAD CHERRY HILL, NEW JERSEY 08003 GA>>22-87E 2023 PARTIAL ROOF RESTORATION at the JOSEPH D. SHARP ELEMENTARY SCHOOL 300 OLD ORCHARD ROAD CHERRY HILL, NEW JERSEY 08003 GA#22-87S 2023 PARTIAL ROOF RESTORATION at the J.F. COOPER ELEMENTARY SCHOOL I960 GREENTREE ROAD CHERRY HILL, NEW JERSEY 08003 GA<<22-87C The Project consists of: 1. Partial Roof Replacement at Cherry Hill High School East, 1750 Kresson Road, Cherry Hill, NJ, 08003. 2. Partial Roof Restoration at James F. Cooper Elementary School, 1960 Greentree Road, Cherry Hill, NJ 08003. 3. Partial Roof Restoration at A. Russel Knight Elementary School, 140 Old Carriage Road, Cherry Hill, NJ 08034. 4. Partial Roof Restoration at Joseph D. Sharp Elementary School, 300 Old Orchard Road, Cherry Hill, NJ 08003. Bidding contractors are strongly encouraged to visit the site of the Project before submitting a bid. Such site visit shall be for the purpose of familiarizing the Contractor with the conditions as they exist and the character of the operations to be carried on under the Contract Documents, including all existing site conditions, access to the site, physical characteristics of the site and surrounding areas. 3. The Contractor shall survey, inspect, and document all existing under-deck conditions (exposed decks and above existing accessible ceilings) at all areas of roof replacement at each school. Identify all conditions that may interfere with roof system installation, including equipment, conduit and wiring mounted tight to the underside of the deck. Coordinate all roof system fasteners and new penetrations to prevent damage to existing systems. Remove and re-install existing systems, if necessary, to prevent damage. If existing systems are damaged due to new roof system installation, the Contractor shall be responsible for all costs to repair equipment and components of the damaged system to their original condition. Electrical systems must be repaired and/or refed by a licensed electrician. If data, security and/or fire alarm systems are damaged, the contractor shall pay all costs for repair, testing and programming to be performed by the Owner's vendor. 4. The project work involves demolition and disposal of the existing roof system and all associated components, installation of the new specified roof system, including all insulation, cover board, membranes, flashing, miscellaneous carpentry, electrical, plumbing, and mechanical work as required to accomplish the roofing work as indicated in the Contract Documents. 5. The scope of work also includes new metal wall panel assemblies at rising wall conditions as well as miscellaneous maintenance and waterproofing throughout the roof areas as noted on the contract documents. 6. Provide crickets/gussets as indicated on the new roof plan. In addition, provide crickets to divert water around all roof penetrations/obstructions. Sections shall be tapered to achieve proper slope as indicated. Provide additional mechanical fasteners at all roof edges and roof corners to meet code requirements. 7. Remove, raise the wood blocking curb and reinstall all rooftop equipment noted on the plans to be raised in order to maintain a minimum of 8" above the finished roof surface. Disconnect electrical service and controls and extend wiring/controls as necessary to meet minimum curb heights as mentioned above and/or noted on drawings. 8. Electrical work associated with replacement, removal and reinstallation of roof top equipment 9. All vent piping shall be a minimum of 12" above the finished roof surface. Provide extensions of vent piping as required. 10. The contractor shall provide a professional third party cleaning company on a daily basis to do protection work and cleaning below the roof deck in areas where there is demolition work occurring. The crew shall prep by covering all finishes with plastic and covering all fire detection devices, equipment, etc. The cleanup should be comprehensive following the roofing work including damp towel wiping down all surfaces, mopping all floors, vacuuming all carpets and vacuuming above all acoustical tile ceilings and all accessible finished ceiling areas. 11. The Roof Manufacturer shall provide Certified Roof Inspection Services to ensure the Owner of compliance with the manufacturer's installation requirements for their products and the warranty. The Roof Manufacturer's Daily Inspection Reports shall be issued to the Construction Manager daily via email. Handwritten notes are acceptable. Weekly summary reports shall be provided to the Construction Manager. 12. Temporarily protect / tarp and support all existing rooftop equipment in the area of work during construction activities. Do not store materials or tools on existing equipment. 13. The Contractor is not permitted access on any roof areas not in the contract. No one is to walk on or store any materials on adjacent roof areas that are not in the contract. 14. The Contractor shall locate all subsurface wires, cables, pipes and pipeline in and around the work area prior to construction at each site. See General Conditions Section 2.2.3 for additional information. 15. Dispose of material according to state and local code and Section 01524 - Construction Waste Management. 16. Restore all grades, lawns, concrete curbing and sidewalks, asphalt and pavement areas that are damaged due to the construction to pre-construction condition School Specific Summary Scope of Work: 1. Cherry Hill High School East - Partial Roof Replacement a. Demolition (tear-off) of existing low-sloped built-up roof system, leaving in place built-up roof directly adhered to gypsum deck where noted on the drawings. b. New tapered or uniform thickness polyisocyanurate insulation. Provide the base layer of insulation mechanically fastened to the gypsum deck with steel auger fasteners, subsequent layers adhered with hot asphalt. Include all sumps, crickets, gussets, etc. c. New 1/2 " high density wood fiber cover board adhered in hot asphalt. d. New 80 mil SBS-modified asphalt base ply adhered in hot asphalt. e. New 160 mil SBS-modified asphalt mineral-surfaced cap ply adhered in cold-applied asphalt adhesive. f. New 2-ply flashings at all walls and curbs, consisting of 40 mil SBS-modified asphalt base ply and 160 mil SBS-modified asphalt mineral-surfaced cap ply. g. New cast iron roof drain assemblies. Provide insulation on the roof drain and a minimum of 5 feet of pipe insulation on the existing piping. h. New soft metal flashing at plumbing stacks and roof drains. New aluminum cape and collar flashing at hot flue stacks. New fluid-applied flashing at other roof penetrations. i. New wood blocking where required to raise roof perimeter edges, equipment curbing, expansion joint curbing, etc. in order to accommodate new finished roof height. j. New through wall flashing and masonry veneer work at designated masonry walls where existing through-wall flashing height is inadequate for new finished roof height. k. Masonry brick veneer infill at the auditorium walls. Remove and replace the masonry in order to install raised new through wall flashing. Masonry tieback fastener installation at the precast architectural concrete veneer parapet at the gymnasium. l. Preventive maintenance work at the existing 18 year old roof areas, consisting of cleaning, roof drain maintenance, surface restoration and penetration flashing renewal. m. New metal wall panels at designated rising wall locations, including air and water barrier membrane, polyisocyanurate insulation, and 22 gauge minimum horizontal z furring. n. New aluminum expansion joint covers. o. New kynar-finished aluminum perimeter metal (copings and fascia), scuppers, collector boxes, and downspouts. All coping shall be shop welded and finished. No field cut connections or joints shall be permitted. 2. Cooper, Knight, and Sharp Elementary Schools - Gravel Surface Partial Roof Restoration a. Preparation of existing roof including field repair and removal of loose gravel surfacing from field of roof (only firmly embedded gravel to remain) and cleaning of all dirt and debris from roof surface. b. Asphalt primer applied to existing roof surface. c. New ply of flashing membrane at all wall and curb flashing. d. New cast iron roof drain assemblies. Provide insulation on the roof drain and a minimum of 5 feet of pipe insulation on the existing piping. e. New soft metal flashing at soil stacks and roof drains. New aluminum cape and collar flashing at hot flue stacks. New fluid-applied flashing at other roof penetrations. f. New kynar-finished perimeter metal. g. New flood coat applied over roof surface with aggregate surfacing. 3. Knight Elementary School - Mineral Surfaced Roof Restoration a. Preparation of existing roof including repairs and surface washing to remove dirt, loose mineral, and other debris. b. New SBS-modified cap flashing ply at perimeter. c. New cast iron roof drain assemblies. Provide insulation on the roof drain and a minimum of 5 feet of pipe insulation on the existing piping. d. New soft metal flashing at soil stacks and roof drains. New fluid-applied flashing at other roof penetrations. e. New kynar-finished perimeter metal. f. New fluid-applied aliphatic polyurea roof membrane installed over existing roof field and flashings. 4. Sharp Elementary School - Front Facade Metal Wall Panels a. Remove existing wall panels and trim components between roof fascia and second floor classroom windows. b. New metal wall panels at designated rising wall locations, including air and water barrier membrane, polyisocyanurate insulation, and 22 gauge minimum horizontal z furring
Award
Educational
$6,991,500.00
Public - City
Renovation
Trades Specified
Division 00 - Lorem Ipsum
One Low Price
- One license and one market
- Details and key contacts on all bidding projects
- Organize your pipeline with a digital bid board
- Automatically match opportunities to your profile
- Saved searches deliver daily project leads to your email inbox
Market Pricing Around
- All Starter Product functionality
- Access to all documents (plans, specifications, and addenda)
- Access to planning projects
- Access to contact information
- Ability to Export
Find More Local Projects
Within 75 Miles of This Project
You’ve Reached the Free View Limit
Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.
Come back in [[refresh_days]] to get [[project_count]] more free projects.
February 23, 2023
April 24, 2023
Multiple Locations, Cherry Hill, NJ
Related To This Project
Cherry Hill, NJ
Bid Date: Mar 03 2023
Cherry Hill, NJ
Bid Date: Mar 09 2023
Cherry Hill, NJ
Bid Date: Mar 08 2023
Cherry Hill, NJ
Bid Date: Feb 24 2023
Cherry Hill, NJ
Bid Date: Mar 09 2023
Cherry Hill, NJ
Bid Date: Apr 27 2023
Cherry Hill, NJ
--
Cherry Hill, NJ
Bid Date: Feb 09 2023
Cherry Hill, NJ
Bid Date: Feb 02 2023
Cherry Hill, NJ
Bid Date: Feb 01 2023
Cherry Hill, NJ
Bid Date: Jan 10 2023
Cherry Hill, NJ
Bid Date: Aug 30 2022
Cherry Hill, NJ
--
Recently Viewed
--
--
--
--
--
--
--
--
--
--
The data you need to build the relationships you want. Try it free.
Sign up now to get free company and project data. No payment required.
Get the right
data with Project Intelligence
Project Shared
with
example@example.com
Choose what you would like to do.
Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.
What is your business type?
We have a wide variety of products that are purpose built for certain business types.