BLOCK PAGE!!!

Subscribe For Access

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Saving Project...

Site work for a water / sewer project in Ford, Kentucky. Completed plans call for site work for a water / sewer project.

Provide recommendations for cathodic protection based on field soil resistivity measurements Calculation Parameters: 1. The pipe will be installed in two sections a. The first section will be installed between Alexandria Pike and U.S. Route 27, a distance of approximately 520-ft b. The second section will be installed between Bob Huber Drive and the Claryville elevated water tank, a distance of approximately 1,540-ft c. The section of pipe between the west side of U.S. Route 27 and the east side of Bob Huber Drive (approximately 400-ft) is not being replaced. d. All tie-ins will be made to existing 12-inch water main. 2. The 2,500-ft of 16-inch polyethylene encased ductile iron pipe has an OD of 17.4-inch (DI specifications) 3. Majority of pipe will be installed to a minimum depth of 5.5-ft; approximately 700-ft of pipe will be installed to a minimum depth of 9.5-ft 4. The average soil resistivity in the Barnes Soil Layer Calculations for the 5.0-ft to 7.5-ft layer is 1,399-ohm-cm. The average soil resistivity in the Barnes Soil Layer Calculations for the 7.5-ft to 10.0-ft layer in the area of the deeper pipe location is 1,870-ohm-cm. 5. We ran two calculations using average soil resistivity readings of 1,400 ohm-cm and 1,870- ohm-cm. 6. The low soil resistivities indicate a very corrosive environment with respect to ductile iron pipe and an anticipated high current output of magnesium anodes, thus a reduced calculated design life. A 48-lb magnesium anode will provide the longest calculated life. 7. Zinc anodes were considered in the design, but they did not provide any longer calculated design life and there were only a few locations where the resistivities were under 1,000 ohmcm. 8. Consider only 2% of the pipe will be exposed to the surrounding environment due to tears of the polyethylene encasement during backfilling 9. Use 1.5 ma/sq-ft surface area current density for the exposed ductile iron pipe Engineers estimate is $1,239,599.90. Construction of approximately 2,080 linear feet of 16 class 50 ductile iron pipe water main together with the appurtenances and related work for a cross country water main from the water tower to old Alexandria Pike near Alexandria, Campbell County, Kentucky.

Award

Water / Sewer

$1,024,385.00

Public - County

Site Work

19

11

9

3

Subscribe For Documents

21 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
48
Active Projects
21
Bidding Soon
506
All Active Projects
230
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

August 3, 2023

October 2, 2023

img_map_placeholder

Multiple Locations, Ford, KY

Related To This Project


The data you need to build the relationships you want. Try it free.

Access Now

Get the right
data with Project Intelligence

Share with your network.

Project Shared

with

example@example.com

Upgrade now for industry‑leading commercial construction data.

You've reached the free-view limit.

Thousands of projects are added every week - don't miss out. Explore the best product options for your business and subscribe today.

Get Access Now

Choose what you would like to do.

Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.