Published November 24, 2023 at 7:00 PM

Updated January 26, 2024

Renovation of a municipal facility in St. John's, Newfoundland. Completed plans call for the renovation of a municipal facility.

Closing Time: 2:30 PM (NT) Complete fire alarm system replacement including the fire alarm panel, remote annunciator, initiating and signaling devices along with the installation of new devices and equipment where required at this time including the replacement of a three horns with bells to match existing tones throughout and installation of relays for HVAC shutdown features. Sound levels will be measured throughout the facility and bells will be added in areas that do not meet the minimum sound level requirements. This will ensure CAN/UL S524 2014 code compliance of the fire alarm system. Existing device locations, conduit and wiring will be conserved. Conduit will be added where bells will be added. These will be indicated on contract documents (drawings). An allowance for the addition of 20 new bells, including asbestos abatement, is included in the cost estimate. The building's fire alarm system consists of approximately 23 manual pull stations, 25 smoke detectors and 19 duct smoke detectors. The system also includes 44 bells, 17 strobes, 1 horn and 2 horn/strobe combination units. Different sound types cannot be present within a fire alarm system, three horns will need to be replaced with bells to rectify this issue. Addressable interface modules are installed to accept dry contacts from sprinkler zone flow switches, supervised valves and low-pressure switches and fire alarm relays are installed for specific control functions. The fire alarm system is integrated with the building management system to provide shutdown of the air handling equipment on a fire alarm condition. This will need to be modified as a life safety system cannot depend on a building management system for life safety control functions. Monitoring of the fire alarm system is done by Troy Life & Fire Safety Ltd. and two means of communication is done via a phone line dialer and a cellular dialer. Question Acceptance Deadline Nov 20, 2023 02:30 PM NST Official bid documents must be obtained from www.bgis.merx.com and bid submissions must be done through the Merx platform.

Post-Bid

Municipal

$125,700.00

Public - Federal

Renovation

10

19

Subscribe For Documents

6 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
36
Active Projects
17
Bidding Soon
250
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

November 24, 2023

December 25, 2023

Project location map

290 Empire Ave, St. John's, NL

Related To This Project


Recently Viewed

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.