Renovation of an educational facility in Baltimore, Maryland. Completed plans call for the renovation of a educational facility.
This project consists of installing an exhaust fan system in order to reduce humidity problem in the basement/garage space. Previously the space was used to refill city trucks with a saline solution for treating roads and will now be used as paper storage. The system will utilize the blocked off window and what is remaining of the nonfunctioning exhaust system located in the basement area that has been blocked off by CMU block. The system will also need a sufficient source of power routed from main floor as there is none in the space. There is currently no functional exhaust service in the area so contractor will be responsible for exhaust fans, associated ductwork, electric, inlet/relief louvers, burglar bars, exhaust system controls as well as safety controls. The successful contractor shall provide all labor, equipment, tools, materials and supplies required to create a properly functioning system. This project is located at the 500 N. Hilton St. building. Al Minority Business Enterprise are encouraged to respond to this solicitation. This is for Small Business Reserve vendors only. Small Business Reserve Designation - Yes The deadline for questions has been established as _08/28/23 at 2pm , to assure that there is enough time to allow the A/E to provide responses and Addendum issuance if necessary. Please submit all questions to the Procurement Officer: James Alston - james.alston1@maryland.gov and Supervisor Christine Stenhouse - christine.stenhouse1@maryland.gov. This project consists of installing an exhaust fan system in order to reduce humidity problem in the basement/garage space. Previously the space was used to refill city trucks with a saline solution for treating roads and will now be used as paper storage. The system will utilize the blocked off window and what is remaining of the nonfunctioning exhaust system located in the basement area that has been blocked off by CMU block. The system will also need a sufficient source of power routed from main floor as there is none in the space. There is currently no functional exhaust service in the area so contractor will be responsible for exhaust fans, associated ductwork, electric, inlet/relief louvers, burglar bars, exhaust system controls as well as safety controls. The successful contractor shall provide all labor, equipment, tools, materials and supplies required to create a properly functioning system A. Contractor should ensure any and all equipment installed and any and all work performed shall be in accordance with all applicable standards and regulations as well as the standards established by: 1. Occupational Health and Safety (OSHA) B. It is the Contractor's responsibility to coordinate the placement of the equipment to be installed with DGS. The Contractor will ensure that the specified equipment can be installed in the available space to affect a safe, legal, code compliant, and properly functioning system. C. All equipment removed and material originating from the job that the Agency elects not to keep shall become the property of the Contractor and shall be removed from the facility and disposed of legally. All rigging, hoisting, lifting and moving equipment necessary to perform the work is to be provided by the Contractor. All storage expenses for inadvertent manifestations shall be the obligation of the contractor. D. The work to be accomplished under this contract is located at 500 N. Hilton Street building and consists of providing all labor, material, equipment and services necessary for what's listed below as well as a complete and functioning product. o Contractor is responsible for equipment and labor required for masonry work with CMU block sufficient for fitting exhaust system. o Contractor must make sure exhaust fan for this project is sufficient for CFM required in garage space that is 142,000ft3. (10,000 CFM based on ACH of 4) o Contractor is responsible for all required controls including but not limited to fan control switch, fan speed control, damper controls, necessary safety controls. o Contractor is responsible for any repair and replacement of existing duct work necessary for a properly functioning system. o Contractor is responsible for supplying and installing burglar bar assembly and intake/relief louvers with bird screen and damper. o Power will need to be run through slab from main floor as there is no sufficient power source in garage. o Contractor should provide and install 100-amp breaker at main panel and 100 amp sub panel (sub panel should be sized for possible addition of walls and HVAC in area) o Contractor is responsible for all material and labor needed. This may include but is not limited to disconnects, breakers, conduit, and all wiring required for fully functional product. E. Any and all materials, design, labor, equipment, tools, or other goods and services not mentioned in this document but necessary to affect a complete, functional, safe, code compliant, turn-key system shall be furnished by the contractor at no additional cost to the state or its agencies. F. The contractor shall provide the facility with operation manuals, documentation, and warranty information for all equipment installed in paper and digital format. G. At the conclusion of the work, the contractor shall attend a walkthrough with the Using Agency Representative and Project Manager. If there are any outstanding issues with the work, a punch list will be prepared, and the punch list items shall be completed within (30) days per DGS General Conditions. H. Contractor is responsible for all permits and fees associated with the project. CALENDAR DAYS TO COMPLETE THE PROJECT: 60 calendar days LIQUIDATED DAMAGES: $ 250.00/day PROCUREMENT OFFICER: Lakecia Dingle / lakecia.dingle@maryland.gov DGS PROJECT MANAGER: John Ferry / john.ferry1@maryland.gov Alvin Ossis / alvin.ossis1@maryland.gov
Bid Results
Educational
$34,500.00
Public - State/Provincial
Renovation
Documents for this project are exclusively Specifications. If Plans become available, we will add them here.
Trades Specified
Division 00 - Lorem Ipsum
Find More Local Projects
Within 75 Miles of This Project
One Low Price
- One license and one market
- Details and key contacts on all bidding projects
- Organize your pipeline with a digital bid board
- Automatically match opportunities to your profile
- Saved searches deliver daily project leads to your email inbox
Market Pricing Around
- All Starter Product functionality
- Access to all documents (plans, specifications, and addenda)
- Access to planning projects
- Access to contact information
- Ability to Export
You’ve Reached the Free View Limit
Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.
Come back in [[refresh_days]] to get [[project_count]] more free projects.
Find better bids. Win.
The best source for commercial construction data, period. Get instant access to up to five free projects and companies. Subscribe all contacts, documents, and details so that you can find new opportunities and win new business.
Get the right
data with Project Intelligence
Project Shared
with
example@example.com
Choose what you would like to do.
Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.
What is your business type?
We have a wide variety of products that are purpose built for certain business types.
September 27, 2023
October 20, 2023
December 19, 2023
500 N Hilton St, Baltimore, MD
Related To This Project
Baltimore, MD
--
Baltimore, MD
Bid Date: Oct 18 2023
Baltimore, MD
Bid Date: Oct 10 2023
Baltimore, MD
--
Baltimore, MD
--
Baltimore, MD
Bid Date: Aug 30 2023
Baltimore, MD
--
Baltimore, MD
--
Baltimore, MD
--
Baltimore, MD
Bid Date: Oct 24 2023
Baltimore, MD
Bid Date: Sep 01 2023
Baltimore, MD
Bid Date: Aug 21 2023
Baltimore, MD
Bid Date: Sep 19 2023
Baltimore, MD
Bid Date: Aug 18 2023
Recently Viewed
--
--
--
--
--
--
--
--
--
--