Privately Funded
Bidding Soon
Documents Available
Publicly Funded
Addenda Available
Post-Bid
Saving Project...
Renovation of an educational facility in Cape Girardeau, Missouri. Completed plans call for the renovation of a educational facility.
The contractor shall provide air filters to be used by Facilities Management for Southeast Missouri State University (hereinafter referred to as "University") in accordance with all terms, conditions and requirements stated herein. All numerical specifications are approximates only. The air filters must meet or exceed the following specifications. 1. Roll Filter, Polyester Media, MERV 8 -The media must be of a high performance design, comprised of 100% polyester fiber. The fiber is to be bonded with a flame-retardant binder to provide a media of strength and durability. The filter shall be tested in accordance with Underwriters Laboratories as UL 900. -The media shall be manufactured using an air laid process to assure consistent web uniformity. -The media shall have a distinct dual density. The coarse, open structure shall be white in color to designate the air entering side of the media. The air leaving side shall be orange in color and tightly needled to provide optimum filtration performance. The media must contain a non-migratory, non-drying adhesive throughout the entire final layer which absorbs and locks in dust particles. -An antimicrobial biocide shall be contained in the media. Biostats are not acceptable. The antimicrobial shall effectively control the growth of mold, algae, mildew, and fungi on the filter. The filter shall not support the growth of microbes. The antimicrobial must have no water solubility. The antimicrobial must be registered by the EPA for use in filters. The antimicrobial must also have clearance for use under regulations of USDA and FDA. All testing on the antimicrobial must be in compliance with the American Society of Test Methods (ASTM). -Each filter shall have a minimum efficiency reporting value of MERV 8 when evaluated under the guidelines of ASHRAE Standard 52.2. The media shall have an average efficiency of 49%, an average arrestance of not less than 91.9%, and a dust holding capacity of 156 grams for a 24 x 24 x 1 panel when tested in accordance with ASHRAE Standard 52.1. Initial resistance at 300 feet per minute approach velocity shall not exceed 0.20" w.g. Equivalent Product: Fiberbond 2. Automatic Roll Filter, MERV 7 -The filter media shall be of a high performance design, comprised of 100% polyester fiber. The fiber is to be bonded with a flame-retardant binder to provide a media of strength and durability. The filter shall be tested in accordance with Underwriters Laboratories as UL 900. -The media shall be manufactured using an air laid process to assure consistent web uniformity. The media shall contain a non-migratory, non-drying adhesive which absorbs and locks in dust particles. -The filter must fit into a Cambridge Model VAR 12-94(s), serial type AM, # AR-55042 48" x 65" x 1" -An antimicrobial biocide shall be contained in the media. Biostats are not acceptable. The antimicrobial shall effectively control the growth of mold, algae, mildew, and fungi on the filter. The filter shall not support the growth of microbes. The antimicrobial must have no water solubility. The antimicrobial must be registered by the EPA for use in filters. The antimicrobial must also have clearance for use under regulations of USDA and FDA. All testing on the antimicrobial must be in compliance with the American Society of Test Methods (ASTM). -Each filter shall have a minimum efficiency reporting value of MERV 7 when evaluated under the guidelines of ASHRAE Standard 52.2. The media shall have an average efficiency of 22.7%, an average arrestance of not less than 85.3%, and a dust holding capacity of 157 grams at 1.0" w.g.for a 24 x 24 x 1 panel when tested in accordance with ASHRAE Standard 52.1. Initial resistance at 300 feet per minute shall not exceed 0.13" w.g. Equivalent Product: Fiberbond FB57604487 (44-7/8) 3. Ring Panel Filters, 1.5" Polyester, MERV 8 -The filter panel shall be of a multi-layered synthetic media design, securely heat sealed around an internal wire support grid. To prevent media fluttering and sifting of trapped dust, the media layers shall 1" Deep Pleated Panel Filter, Medium Efficiency, MERV 8 -The filter must be medium efficiency ASHRAE pleated, disposable type. Each filter must consist of a cotton and synthetic media, welded wire media support grid, and kraft board enclosing frame. The filter must be listed and identified on the frame by Underwriters Laboratories as UL 900. -Each filter shall have no less than 2.3 square feet of media per square foot of filter face area and no less than 16 pleats per linear foot of filter face area. A 96% open area media support grid, coated with rust inhibitor, shall be bonded to the air exiting side of the filter. The enclosing frame shall be of high wetstrength beverage board with diagonal support members bonded to the air entering and air exiting side of each pleat. The inside periphery of the enclosing frame shall be bonded to the filter pack. -Each filter shall have a minimum efficiency reporting value of MERV 8 when evaluated under the guidelines of ASHRAE Standard 52.2. It shall also have a MERV-A of 8 when tested per Appendix J of ASHRAE Standard 52.2. Initial resistance to airflow shall not exceed 0.25" at an airflow of 350 fpm. Manufacturer shall guarantee integrity of product to 2.0" w.g. -The manufacturer shall provide evidence of facility certification to ISO 9001:2008. Equivalent Product: CamFil FARR AeroPleat IV 5. 2" Deep Pleated Panel Filter, Medium Efficiency, MERV 8 -The filter must be medium efficiency ASHRAE pleated, disposable type. Each filter shall consist of cotton and synthetic media, welded wire media support grid, and kraft beverage board enclosing frame. The filter shall be listed and identified on the frame by Underwriters Laboratories as UL 900. -The filter shall have no less than 4.6 square feet of media per square foot of filter face area and no less than 15 pleats per linear foot of filter face area. A 96% open area media support grid, coated with rust inhibitor, shall be bonded to the air exiting side of the filter. The enclosing frame shall be of no less than 28-point high wet-strength beverage board with diagonal support members bonded to the air entering and air exiting side of each pleat. The inside periphery of the enclosing frame shall be bonded to the filter pack. -Each filter shall have a minimum efficiency reporting value of MERV 8 when evaluated under the guidelines of ASHRAEStandard 52.2. It shall also have a MERV-A of 8 when tested per Appendix J of ASHRAE Standard 52.2. The media shall maintain or increase in efficiency over the life of the filter. -Initial resistance to airflow shall not exceed 0.31" w.g. at an airflow of 500 fpm. -The manufacturer shall guarantee the integrity of the filter to 2.0" w.g. The filter shall have an Energy Cost Index (ECI) value of five stars. -The manufacturer shall provide evidence of facility certification to ISO 9001:2008. Equivalent Product: CamFil FARR 30/30 Question Deadline 01/24/2024
Post-Bid
Educational
$200,000.00
Public - State/Provincial
Renovation
Documents for this project are exclusively Specifications. If Plans become available, we will add them here.
4
Trades Specified
Division 00 - Lorem Ipsum
Find More Local Projects
Within 75 Miles of This Project
One Low Price
- One license and one market
- Details and key contacts on all bidding projects
- Organize your pipeline with a digital bid board
- Automatically match opportunities to your profile
- Saved searches deliver daily project leads to your email inbox
Market Pricing Around
- All Starter Product functionality
- Access to all documents (plans, specifications, and addenda)
- Access to planning projects
- Access to contact information
- Ability to Export
You’ve Reached the Free View Limit
Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.
Come back in [[refresh_days]] to get [[project_count]] more free projects.
January 31, 2024
March 1, 2024
To Be Determined, Cape Girardeau, MO
Related To This Project
Cape Girardeau, MO
Bid Date: Feb 06 2024
Cape Girardeau, MO
Bid Date: Mar 05 2024
Cape Girardeau, MO
Bid Date: Mar 15 2024
Cape Girardeau, MO
Bid Date: Feb 27 2024
Cape Girardeau, MO
Bid Date: Mar 07 2024
Cape Girardeau, MO
Bid Date: Mar 26 2024
Cape Girardeau, MO
Bid Date: Apr 24 2024
Cape Girardeau, MO
Bid Date: Apr 09 2024
Cape Girardeau, MO
Bid Date: Jan 26 2024
Cape Girardeau, MO
Bid Date: Jan 16 2024
Cape Girardeau, MO
Bid Date: Dec 15 2023
Cape Girardeau, MO
Bid Date: Dec 14 2023
Cape Girardeau, MO
Bid Date: Dec 14 2023
Cape Girardeau, MO
Bid Date: Dec 14 2023
Cape Girardeau, MO
Bid Date: Dec 14 2023
Recently Viewed
--
--
--
--
--
--
--
--
--
--
The best commercial construction data available. Period.
Sign up now to get instant access to project search, five projects and five companies, free.
Get the right
data with Project Intelligence
Project Shared
with
example@example.com
Choose what you would like to do.
Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.
What is your business type?
We have a wide variety of products that are purpose built for certain business types.