BLOCK PAGE!!!

Subscribe For Access

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Saving Project...

Renovation of a laboratory facility in Gunpowder, Maryland. Completed plans call for the renovation of a laboratory facility.

SYNOPSIS/SOLICITATION W91ZLK-24-R-0020 This combined synopsis/solicitation is for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. Incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2024-05 (22 APR 2024). The solicitation number for this request for proposal (RFP) is W91ZLK-24-R-0020. This requirement is under the associated North American Industry Classification System (NAICS) Code 238190 - Other Foundation, Structure, and Building Exterior Contractors. The Government contemplates award of a Purchase Order on a firm-fixed price (FFP) basis as a 100% Small Business Set-Aside in accordance with FAR 13, Simplified Acquisition Procedures. The period of performance is within (3) months from the date of award for the base requirement and (12) months for the option requirements. This procurement will be evaluated as Lowest Price Technically Acceptable, for the procurement of the following services. The Repair and Recoat of Floors and Walls with Chemical Resistant Epoxy (See Attachment 2 - Performance Work Statement). Award will be made to the Offeror whose response to the Combined Synopsis/Solicitation represents the best value to the Government. Proposals will be evaluated in accordance with the Lowest Price Technically Acceptable (LPTA) Source Selection process described in FAR 15.101-2. All questions must be submitted via email to terrijuana.p.veals.civ@army.mil by Wednesday, July 17, 2024 at 10am Eastern Time. SUBJECT LINE: W91ZLK-24-R-0020 Q&A for Combined Synopsis/Solicitation FROM (INSERT COMPANY NAME). Firm Fixed Price (FFP) proposals must be signed, dated, and received by Thursday, August 8, 2024 at 10am Eastern Time. SUBJECT LINE: W91ZLK-24-R-0020 Proposal FROM (INSERT COMPANY NAME). All additional questions will be answered via an amendment to the Combined Synopsis/Solicitation on www.SAM.gov. The Contractor, as an independent party and not an agent of the Government, shall provide The Repair and Recoat of Floors and Walls with Chemical Resistant Epoxy of the Chemical Transfer Facility (CTF) sump area, secondary holding tank area, and select laboratories and storage rooms to ensure containment of any hazardous or aggressive chemicals, should there ever be a leak in the system. Business hours are 7:00AM - 5:00PM Eastern Standard Time, Monday through Friday, excluding federal holidays. All work to be performed will be inspected for compliance with performance requirements by the Contracting Officer's Representative (COR). SUBMISSION PROCEDURES FOR PROPOSAL: 52.212-1 Instruction to Offerors Commercial Items This clause applies in its entirety and there are currently no addenda to the provision. NO QUESTIONS FOR THE COMBINED SYNOPSIS/SOLICITATION WILL BE ACCEPTED VIA PHONE CALLS. All proposals from responsible sources will be considered. Offerors who are not registered in the System for Award Management (SAM) database at the time of proposal will not be considered. Offerors may register with SAM by calling 1-866-606-8220 or online at www.SAM.gov. Ofterors are cautioned to ensure that their proposals contain all necessary information and are complete in all respects as the Government does not intend to conduct discussions; therefore, proposals shall represent the best and final offer of the Contractor. Proposals shall be submitted in two (2) separate volumes labeled: Volume I: Epoxy Services W91ZLK-24-R-0020 TECHNICAL Proposal Volume II: Epoxy Services W91ZLK-24-R-0020 PRICE Proposal Formatting. Single space Text Double Space Paragraphs 12-point minimum font size. Arial or New Times Roman fonts only. Table/illustrations 8-point min and landscape is acceptable. Margins: All Margins 1 inch. Gutter: 0 inches Header and Footer 1.5 inches Page Size: Width 8.5 inches and Height 11 inches (11 X 17 folded pages are acceptable for tables/graphic representations; however, each 11 X 17 page counts as two pages) Page Limitations: Volume I Technical - 5 pages limit and Volume II Price - unlimited pages. Plain Text Proposals(, i.e., no identifying graphics, logo, watermarks, etc.) NOTE: Pages that exceed the required page limitations will not be evaluated. Additional pages over the maximum allowed will be removed or not read and will not be evaluated by the Government. Restrictions: All information shall be confined to the appropriate volume. The Offeror shall confine submissions to essential matters and sufficient to define the proposal in a concise manner, to permit a complete and accurate evaluation of each proposal. Proprietary information shall be clearly marked. The following shall be included in the volumes: Volume I: Detail Technical Proposal shall be evaluated based on the following factors: a. Factor 1 - Technical Approach: The offeror's proposal shall adequately describe and present a clear understanding of the requirements specified in the Performance Work Statement (PWS). To be rated as acceptable, offerors must provide documentation that demonstrates the offeror's approach for meeting all of the requirements specified in the PWS. b. Factor 2 - Experience: Contractor shall demonstrate the ability to repair and recoat the floors and walls with chemical resistant epoxy for the CTF sump area, secondary holding tank area, and select laboratories and storage rooms to ensure containment of any hazardous or aggressive chemicals, should there ever be a leak in the system as specified in the PWS. To be rated as acceptable, the offeror must provide documentation to demonstrate recent experience repairing and recoating floors and walls with chemical resistant epoxy according to the PWS. Recent experience includes epoxy services performed within five (5) years (i.e. previous Government contracts). BASIS FOR AWARD: The award will be made to one responsible offeror whose proposal is determined to be technically acceptable, and lowest priced. To receive consideration for an award, an "Acceptable" rating must be achieved for all the non-cost evaluation factors: Technical Approach and Experience. Price will be evaluated in accordance with FAR 15.404-1 Proposal analysis techniques. Price will be the determining factor for proposals rated as acceptable for the non-cost factors. Price analysis using one or more methods listed under FAR 15.404-1(b) will be used to ensure that the proposal will result in a fair and reasonable price. Volume II: Detailed Price Proposal to include the following elements: Header Page Company Name, DUNS, CAGE, Business Type/Size, ETN# and point of contact information to include: Name, title, email address, and telephone number including extension. INCLUDE ALL Information Below (An excel attachment will be provided to submit as a part of Volume II): CLIN Requirement Epoxy Flooring Area *No aggressive chemical resistance Description QTY: 1 Price Total Price FFP Additional Details CLIN 0001 Base SRF Room 149 Approx. 1,000 sq. ft. 1 $ - CLIN 0002 Option #1 SRF Foyer to Room 149 Approx. 96 sq. ft. 1 $ - Incl. approx. 15 sq. ft. of Safety Yellow CLIN 0003 Option #2 SRF Foyer to Room 167 Approx. 23 sq. ft. 1 $ - CLIN 0004 Option #3 SRF Room 167 Approx. 789 sq. ft. 1 $ - Incl. approx. 70 sq. ft. of Safety Yellow CLIN 0005 Option #4 SRF Room 157 Approx. 86 sq. ft. 1 $ - Incl. approx. 35 sq. ft. of Safety Yellow CLIN 0006 Option #5 SRF Room 166 Approx. 472 sq. ft. 1 $ - CLIN 0007 Option #6 SRF Room 137 Approx. 1743 sq. ft. 1 $ - Incl. approx. 208 sq. ft. of Safety Yellow CLIN 0008 Option #7 SRF Hallway Approx. 2069 sq. ft. 1 $ - CLIN 0009 Option #8 SRF Room 165 Approx. 515 sq. ft. 1 $ - CLIN 0010 Option #9 SRF Bathroom Hallway* Approx. 358 sq. ft. 1 $ - CLIN 0011 Option #10 SRF Bathroom* Approx. 267 sq. ft. 1 $ - CLIN 0012 Option #11 CTF Room 1 Approx. 200 sq. ft. 1 $ - Existing berms, spill containment troughs, and/or spill containment side-coves expected to remain berms, spill containment troughs, and/or spill containment side-coves with epoxy services CLIN 0013 Option #12 CTF Room 4 Approx. 200 sq. ft. 1 $ - CLIN 0014 Option #13 CTF Room 5 Approx. 200 sq. ft. 1 $ - CLIN 0015 Option #14 CTF Room 6 Approx. 200 sq. ft. 1 $ - CLIN 0016 Option #15 CTF Room 7 Approx. 200 sq. ft. 1 $ - CLIN 0017 Option #16 CTF Room 8 Approx. 200 sq. ft. 1 $ - CLIN 0018 Option #17 CTF Room 12 Approx. 200 sq. ft. 1 $ - CLIN 0019 Option #18 CTF Room 13 Approx. 200 sq. ft. 1 $ - CLIN 0020 Option #19 CTF Room 22 Approx. 235 sq. ft. 1 $ - CLIN 0021 Option #20 CTF Room 23 Approx. 200 sq. ft. 1 $ - CLIN 0022 Option #21 CTF Room 24* Approx. 90 sq. ft. 1 $ - CLIN 0023 Option #22 CTF Room 27 Approx. 400 sq. ft. 1 $ - CLIN 0024 Option #23 CTF Room 30 Approx. 300 sq. ft. 1 $ - CLIN 0025 Option #24 CTF Room 32 Approx. 300 sq. ft. 1 $ - CLIN 0026 Option #25 CTF Walkin- Freezers Approx. 251 sq. ft. 1 $ - CLIN 0027 Option #26 CTF Locker Room #20 Approx. 84 sq. ft. 1 $ - CLIN 0028 Option #27 CTF Locker Room #21 Approx. 200 sq. ft. 1 $ - CLIN 0029 Option #28 CTF Bathroom #17 Approx. 80 sq. ft. 1 $ - CLIN 0030 Option #29 CTF Mechanical Room Approx. 1447 sq. ft. 1 $ - CLIN 0031 Option #30 CTF Operational Hallway Approx. 2175 sq. ft. 1 $ - CLIN 0032 Option #31 CTF Office Hallway Approx. 197 sq. ft. 1 $ - Incl. approx. 300 CI of expansion joint LIST OF ATTACHMENTS: PROVISIONS/CLAUSES: See Attachment 1 - Provisions/Clauses PERFORMANCE WORK STATEMENT: See Attachment 2 - Performance Work Statement. QUALITY ASSURANCE SURVEILLANCE PLAN (QASP): See Attachment 3 - Quality Assurance Surveillance Plan PRICE LIST: See Attachment 4 - Price List (Use for Volume II - Detailed Price Proposal)

Post-Bid

Laboratories

$50,000.00

Public - Federal

Renovation

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

7

Subscribe For Documents

6 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
264
Active Projects
106
Bidding Soon
2,745
All Active Projects
1,204
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

August 28, 2024

September 27, 2024

img_map_placeholder

8897 Guard St, Gunpowder, MD

Related To This Project


Get the most reliable construction project data instantly.

Access Now

Get the right
data with Project Intelligence

Share with your network.

Project Shared

with

example@example.com

Upgrade now for industry‑leading commercial construction data.

You've reached the free-view limit.

Thousands of projects are added every week - don't miss out. Explore the best product options for your business and subscribe today.

Get Access Now

Choose what you would like to do.

Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.