BLOCK PAGE!!!
Get Full Details

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Published September 5, 2024 at 8:00 PM

Updated September 6, 2024

Renovation of a medical facility in St. John's, Newfoundland. Completed plans call for the renovation of a medical facility.

Closing Time: 2:00 PM (NT) ** Please note that there has been 4 addendum issued for this project. ** The Question Deadline 08/07/2024 has been changed and will now be on Wednesday, August 21st , 2024 at 12:00:00 Question Acceptance Deadline 2024/08/21 12:00:00 PM NDT 1 Design, supply, and erect scaffolding as required to facilitate requirements of this project. 2 Walk-Through Scaffolding Frames: The walk-through scaffolding frames are required to have a width of not less than 1524 mm (5 feet) (center-to-center between columns) and to have working platform levels (deck levels) not less than 1930mm (6 feet 4 inches) between platform levels. Skywalk masonry frames are approved for use on this project. 3 Working Platforms: .1 Provide working platforms (deck levels) at all work levels, consisting of three metal-framed, plywood-decked scaffolding planks, each having a width of not less than 482.6mm (19 inches). 2 Provide side brackets at all levels having a width of not less than 508mm (20 inches) and capable of safely supporting a standard 482.6mm (19 inch) wide metal-framed, plywood-decked plank. Provide decks on all levels of side brackets. 3 Platform Deck: The platform deck is required to be constructed of aluminium or steel frames with plywood decks, such as Mac Decks by Aluma Systems and approved equivalent to safely support the vertical loading specified within Section 01 53 50, Item 3.3.1 of the Project Specifications. 4 Transverse Deck Line Loading for Scaffolding Frame Design: With respect to the scaffolding frame design, the transverse deck line load of 3.63 kN (250 lbs.) is only required for one level of decking. Scaffolding frames having scaffolding decks on both sides of the scaffolding frames are, therefore, required to withstand a line load of 7.26 kN (500 lbs.) across the width of the scaffolding frames. Official bid documents must be obtained from www.merx.com and bid submissions must be done through the Merx platform.

Bid Results

Medical

$1,097,422.00

Public - State/Provincial

Renovation

16

29

19

Subscribe For Documents

40 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
36
Active Projects
18
Bidding Soon
250
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

September 5, 2024

September 23, 2024

Project location map

154 Lemarchant Rd, St. John's, NL

Related To This Project


Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.