BLOCK PAGE!!!

Subscribe For Access

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Saving Project...

Renovation of a water / sewer project in Rock Hill, South Carolina. Completed plans call for the renovation of a water / sewer project.

The City of Rock Hill, South Carolina (City) is seeking competitive bids from qualified companies to provide pad-mount transformers for the City's Wastewater Treatment Plant Expansion. The City of Rock Hill, South Carolina is seeking competitive bids from qualified companies to provide the City with Pad-mount Transformers for Wastewater Treatment Plant. The initial term of the resulting agreement is upon completion. The anticipated start date is November 1, 2024. The Electric Utilities Department is responsible for this project. Transformer Specifications: 2,500 & 2,000 kVA Pad-mount 24,940 Delta - 480 Y/277 Volts A. These specifications cover the electrical and mechanical features of three-phase, 60 hertz, 65 degrees C rise, mineral oil filled, pad-mounted, compartmental type distribution transformers with separable insulated high voltage connectors. Transformers shall be furnished completely assembled and filled with oil. Bidder shall certify that transformer oil contains no PCB contaminants. B. Transformers shall comply with the latest revision of ANSI C57.12.26, except where it conflicts with the specific requirements of these specifications. C. All transformers manufactured under this specification shall be tested for no load (85 degrees C) and total (85 degrees C) losses, percent impedance (85 degrees C) and exiting current (100% voltage), and subject to a full wave voltage impulse. Actual loss data shall be prepared in accordance with the attached form. D. Each bidder shall supply verification that the design has passed short circuit criteria per ANSI C57.12.00 - 1980 and ANSI C57.12.90 - 1980. E. All ANSI standards contained in the specifications refer to the latest revision. F. Transformer shall be three-phase, pad-mounted distribution type, 60 hertz, liquid immersed, self--cooled, and suitable for outdoor service. G. Transformer shall be rated 24,940 Delta - 480 GrdY/277 volts, 60 hertz, 125 KV BIL. The transformer shall have an average winding rise not exceeding 65 degrees Centigrade. KVA ratings shall be as specified in the proposal section at the end of this schedule. H. Transformer shall have six primary bushing wells suitable for use with 200-ampere loadbreak bushing inserts. Primary connections shall be arranged for loop-feed. Transformer shall have three insulated secondary bushings and one grounded secondary neutral bushing. Secondary bushings shall have spade type terminals with NEMA standard ten (10) hole spacing. There shall be a parking stand for each primary bushing. I. Transformer shall be delta-wye connected and shall have a five-legged core or other means of avoiding tank heating due to third harmonics. Transformer shall be furnished with a parking stand for each primary bushing. J. Transformer shall be equipped with three primary liquid-immersed fault-sensing expulsion type loadbreak fuses in series with internal current limiting fuses, with provisions for hotstick removal. Transformer shall also be equipped with a pressure-vacuum gauge and a pressure relief device. The tank will be constructed to withstand a minimum of 12 psig with rupture. K. Transformer shall be dead-front primary type with separate high- and low-voltage compartments. The high-voltage compartment shall be fastened from inside the low-voltage compartment, and the low-voltage compartment shall have provision for padlocking. The unit shall be suitable for installation without a fence or other protective enclosure. L. Transformer shall have a complete nameplate inside and outside the low-voltage compartment, external tap changer handle, provision for tank grounding, and provision for bolting to a foundation pad. Transformer shall conform to the requirements of ANSI Standard C57.12.22 except where the standards conflict with the requirements of these specifications. The unit shall be regular in the outline with no projection other than cooling fans, lifting lugs, and door handle. M. The following shall be included for the transformer: 1. Nameplate 2. Transformer shall be completely assembled and filled with mineral oil and bidder shall certify that transformer liquid contains no PCB contaminates. A level indication such as a pipe plug shall be provided. 3. Guaranteed performance data shall be attached to this proposal and bidder's price shall include furnishing actual test data on the transformer using standard test in accordance with ANSI Standard C57.12.90. 4. A minimum of 36" front to back for high and low voltage compartments. N. All transformers shall pass the following tests: 1. Connection Test 2. Demagnetization 3. High to Low Iron Continuity 4. Low to High Iron Continuity 5. 400 Hertz over Potential 6. Iron Loss 7. Impulse Test O. The transformers shall be of sealed tank construction and sufficient strength to withstand a pressure of 7 PSI without permanent distortion. In addition to regular locking provisions, all access doors or hoods shall be secured by a recessed and captive pentahead bolt.

Post-Bid

Water / Sewer

$100,000.00

Public - City

Renovation

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

6

Subscribe For Documents

27 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
133
Active Projects
66
Bidding Soon
1,119
All Active Projects
508
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

November 12, 2024

November 22, 2024

img_map_placeholder

2102 Cherry Rd, Rock Hill, SC

Get the most reliable construction project data instantly.

Access Now

Get the right
data with Project Intelligence

Share with your network.

Project Shared

with

example@example.com

Upgrade now for industry‑leading commercial construction data.

You've reached the free-view limit.

Thousands of projects are added every week - don't miss out. Explore the best product options for your business and subscribe today.

Get Access Now

Choose what you would like to do.

Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.