Privately Funded
Bidding Soon
Documents Available
Publicly Funded
Addenda Available
Post-Bid
Saving Project...
This is a service / maintenance or supply contract in Commerce Township, Michigan. Contact the soliciting agency for additional information.
Reference Number 0000370764 The Oakland County Water Resources Commissioner (OCWRC) operates and maintains the Commerce Twp. Wastewater Treatment Plant (COT WWTP), which currently operates and maintains approximately 2MGD from the surrounding collection system. Prior to discharge back into the environment, the effluent water is sampled with an auto sampler within the WWTP. OCWRC is seeking bids for an automatic, refrigerated sampler per the included specification requirements. This solicitation includes the provision, delivery, and warranty of the specified product. Delivery Point Commerce Wastewater Treatment Plant 649 Welch Road Walled Lake, MI 48390 SPECIFICATIONS Approved product is ISCO Model 5800 Package, including: Model 5800 Refrigerated Sampler. Includes control panel, refrigeration unit, distributor arm and two pump tubes. Single bottle configuration. Includes one polyethylene 5.5 Gallon (20.5 Liter) round bottle and two discharge tubes. Bottle includes two caps - one solid cap for transport and one with a hole to properly route the discharge tube when sampling. Vinyl suction line with standard weighted polypropylene strainer (3/8 Inch I.D. x 25 ft.). Includes tubing coupler. Required specifications are as follows: Power Requirements: 115 VAC 60 Hz Operational Temperature Requirement: -20 to 120 F (-29 to 49 C) Material Requirement (refrigerator body): Linear low-density polyethylene Pump Requirements: Pump Tubing Life: Typically, 1,000,000 pump counts Maximum Suction Lift: 28 ft. (8.5 m) Typical Repeatability: +-5 mL or +- of the average volume in a seat, whichever is greater, at lifts up to 25 ft. Typical Line Velocity at Head Height of 3 ft/s at 3 ft of head height, 2.9 ft/s at 10 ft of head height, and 2.7 ft/s at 15 ft of head height Liquid Presence Detector: Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights. Control and Software Requirements: Enclosure Rating: NEMA 4X, 6 (IP67) Program Memory: Non-volatile ROM Flow Meter Signal Inputs: 5-to-15-volt DC pulse or 25 ms isolated contact closure for Teledyne ISCO flow meters, 4-20 mA input or non-Teledyne ISCO flow meters. Digital Alarms: 4 programmable outputs; 5V, 100 mA Number of composite samples: Programmable from 1 to 999 samples Sample Frequency: 1 minute to 99 hours 59 minutes in 1-minute increments 1 to 9,999 flow pulses Sampling Requirements: Constant time - constant volume Constant time - variable volume Variable time - constant volume Programmable Sample Volumes: 10 to 9,990 mL in 1 mL increments Sample Retries: If no sample is detected, up to 3 attempts Rinse Cycles: Automatic rinsing of suction line up to 3 rinses each Controller Diagnostics: Test for RAM, ROM, pump, display, and electric components Question Acceptance Deadline 12/19/2024 05:00 PM EST Questions are submitted online Yes Participation Requirements - Disadvantaged Business Enterprise (DBE) - Minority Business Participation - Small Business Participation - Service-Disabled Veteran Owned - Women-Owned Business Participation General Requirements - FOB Destination - Warranty Information Required
Post-Bid
Water / Sewer
Public - County
Service, Maintenance and Supply
Plans and Specifications are not available for this project. If that changes, they will be made available here.
Trades Specified
Division 00 - Lorem Ipsum
One Low Price
- One license and one market
- Details and key contacts on all bidding projects
- Organize your pipeline with a digital bid board
- Automatically match opportunities to your profile
- Saved searches deliver daily project leads to your email inbox
Market Pricing Around
- All Starter Product functionality
- Access to all documents (plans, specifications, and addenda)
- Access to planning projects
- Access to contact information
- Ability to Export
Find More Local Projects
Within 75 Miles of This Project
You’ve Reached the Free View Limit
Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.
Come back in [[refresh_days]] to get [[project_count]] more free projects.
January 2, 2025
February 3, 2025
649 Welch Rd, Commerce Township, MI
Related To This Project
Commerce Township, MI
--
Commerce Township, MI
Bid Date: Dec 17 2024
Commerce Township, MI
Bid Date: Nov 14 2024
Commerce Township, MI
Bid Date: Nov 14 2024
Commerce Township, MI
Bid Date: Nov 06 2024
Commerce Township, MI
Bid Date: Oct 21 2024
Commerce Township, MI
Bid Date: Oct 04 2024
Commerce Township, MI
--
Commerce Township, MI
Bid Date: Nov 07 2024
Commerce Township, MI
Bid Date: Sep 03 2024
Commerce Township, MI
Bid Date: Aug 28 2024
Commerce Township, MI
Bid Date: Aug 27 2024
Commerce Township, MI
Bid Date: Aug 27 2024
Commerce Township, MI
Bid Date: Aug 08 2024
Commerce Township, MI
--
Recently Viewed
--
--
--
--
--
--
--
--
--
--
New Year, New Possibilities. Make the connections you need to kickstart 2025.
Sign up now to get free company and project data. No payment required.
Get the right
data with Project Intelligence
Project Shared
with
example@example.com
Choose what you would like to do.
Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.
What is your business type?
We have a wide variety of products that are purpose built for certain business types.