EN

BLOCK PAGE!!!

Subscribe For Access

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Saving Project...

Published February 21, 2025 at 7:00 PM

Updated October 1, 2024

This is a service / maintenance or supply contract in Detroit, Michigan. Contact the soliciting agency for additional information.

This is a Sources Sought Notice for biological, chemical and pharmacy hood testing and certification services at the Detroit VA Medical Center in Detroit, Michigan. Contractor shall furnish all necessary labor, supervision, management, management support, transportation, supplies, equipment and materials necessary to furnish the following services. The services required are provided below and subject to changes should a solicitation be issued as a result of this notice. Please respond if you have the ability and intent to complete this requirement. Include the following information in your response: SAM UEI (include within email response and in capability statement) Capabilities Statement Company name and address Point of contact information (name, phone, email) Socioeconomic size status (example: large, small, WOSB, SDVOSB, etc.) FSS or GSA contract number, if applicable. This Sources Sought Notice is intended to locate any business capable of performance. The anticipated NAICS Code for this requirement is 541380. This is not a Request for Quotation and quotes shall not be reviewed at this time. The Government shall not be responsible for any costs incurred by the contractor because of this Sources Sought Notice. This notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to any particular acquisition approach. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government. All responses shall be submitted via email by Monday, March 3, 2025 at 10:00 AM Eastern Time (ET). Responses shall be submitted to Jeanne Ortiz at jeanne.ortiz@va.gov and shall include 36C25025Q0318 in the email subject line. PHONE CALLS SHALL NOT BE ACCEPTED FOR THIS NOTICE. DRAFT STATEMENT OF WORK GENERAL INFORMATION The Detroit VA (DVA) Medical Center at 4646 John R. Street, Detroit, Michigan 48201, requires Hood Testing and Certification services. The resulting contract will be firm, fixed-price with a base year and four (4) anticipated option years, at Government discretion. SCOPE OF WORK Semi-Annual: The contractor shall provide all resources necessary to perform and complete the tasks described in this statement of work (SOW), except as may otherwise be specified. This Semi-Annual testing will be done in the calendar year months of May and November. The contractor shall provide all labor, materials, instrumentation, supervision, and all other resources required to perform semi-annual testing and certifications on the following hoods: These rooms are in PALMS, Pharmacy, Nuclear Medicine, and Oncology Annual: The contractor shall provide all resources necessary to perform and complete the tasks described in this statement of work (SOW), except as may otherwise be specified. The Annual testing will be done in the calendar year month of November. The contractor shall provide all labor, materials, instrumentation, supervision, and all other resources required to perform annual testing and certifications on: Background Semi-Annual: Semi-Annual hoods and the IV Clean room are to be tested and certified for proper airflows on an annual and semi-annual basis. The contractor shall test and certify all hoods and the IV Clean room within the John D. Dingell VAMC. The contractor shall perform Semi-Annual testing in the calendar year months of November and May for the testing and certifications. The contractor will schedule the work to ensure there is not more than a 6-month overlap of inspections under the contract period of performance. Background Annual: Annual hoods are to be tested and certified for proper airflows on an annual basis. The contractor shall test and certify all hoods within the John D. Dingell VAMC. The contractor shall perform the Annual testing in the calendar year month of November for testing and certifications. Performance Period: The contractor shall complete the work required under this SOW within the month of November and again in the month of May under the contract period of performance. The work shall take place between the hours of 6:00 am to 4:30 pm, Monday through Friday. Some critical areas may require testing to be scheduled a day ahead of time in order to gain access. This will be scheduled through the COR. The contractor shall complete all testing within five business days from the start date of the initial work. SPECIFIC MANDATORY TASK AND ASSOCIATED DELIVERABLES The contractor shall provide the specific deliverables below within the performance period stated in Section B-5 of this SOW. The contractor shall begin the first semi-annual testing/certification of all the hoods and IV clean room in the month of November of the contract period of performance and complete the work within five business days from when the work was started. The contractor shall begin the second semi-annual testing/certification of all the hoods and IV clean room in the month of May of the contract period of performance and complete the work within five business days from when the work was started. The contractor must provide the Contracting Officer Representative (COR) at least one week notice before starting any testing. The contractor shall communicate with the COR daily during the inspections to inform of any issues with hoods tested that day. The contractor shall notify the COR of any hoods that do not meet certification criteria and supply the COR with a quote for repairs needed to make the hood compliant, prior to leaving the facility. Testing of the Pharmacy IV clean room shall be done on a semi-annual schedule to coincide with the hood testing. The following testing and sampling are required: Airflow Test Citations: USP <797>, CAG-001-2005, CAG-002-2006, Manufacturer Specifications Methods: CAG-002-2006 Locations: LAFW Procedure: Appropriate airflow parameters will be measured using a validated method which will be kept on file. Air velocity will be measured by thermal anemometer using equally spaced readings across a horizontal plane producing the most repeatable readings. The locations within the plane, and the level of the plane in relationship to the filter diffuser will be documented. Reported in feet per minute with % uniformity. Pass/Fail Criteria: PASS Average velocity and uniformity within manufacturer specifications FAIL Average velocity and uniformity outside manufacturer specifications HEPA Filter Integrity Test Citations: USP <797>, CAG-002-2006 Methods: CAG-002-2006, IEST-RP-CC034.2 Section 6.2.1 for filters that can be scan tested IEST-RP-CC034.2 Section 6.2.3 for filters that cannot be scan tested Locations: LAFW Procedure: HEPA filters will be leak tested using a validated method which will be kept on file. An aerosol challenge of 10-90 micrograms per liter of polydispersed dioctylphthalate, polyalphaolefin, or equivalent will be introduced upstream and filter efficacy verified by aerosol photometer scan. Certifier shall have capability to patch and repair HEPA filter up to 3% of the face area per side and not to exceed 1.5 inches in width or provide replacement HEPA filter with filter of like size and construction (Type C or K) on same day. Pass/Fail Criteria: PASS leakage of less than or equal to 0.01% of upstream concentration for filters that can be scanned, or 0.005% for filters that cannot be scanned FAIL leakage of greater than 0.01% or patch size exceeds IEST-RP-CC034 (current version) limit Airflow Smoke Pattern Test Citations: USP <797>, CAG-001-2005, CAG-002-2006 Methods: CAG-002-2006 Locations: LAFW Procedure: Visual observation of airflow patterns, under dynamic operating conditions, demonstrating first-air flow through critical sites within the DCA. Minimal dead spots or reflux away from critical sites is allowable. Methods will be kept on file. Delivery velocity of smoke generator shall not overcome isolator airflow patterns. Results to be video recorded and provided to Facility Program Manager for IV/Sterile Preparations. Pass/Fail Criteria: PASS Airflow demonstrates smooth downflow with no dead spots or refluxing across critical sites. FAIL Airflow does not meet direction or turbulence standards Particle Count Survey Citations: USP <797>, CAG-001-2005, CAG-002-2006 Methods: CAG-002-2006, ISO 14644-1 Locations: LAFW Procedure: Air particle counts will be measured using a validated method which will be kept on file. The pass-through will be tested under static (at-rest) condition and the main chamber under both static and dynamic operating conditions. A discrete particle counter capable of detecting particles of 0.5 micron and larger shall be used. Sampling probe is to be oriented upward and located no more than 12 above the work surface (static test) and 12 away from the critical site (dynamic test). A minimum sample of two liters of air over one minute will be taken for each testing location. Three particle counts will be taken from the geometric center of the pass-through and five particle counts each will be taken in the main chamber under static and dynamic conditions one near each corner, and one in the geometric center. Particle counts will be reported individually for each sampling location and designated by location and testing condition. Pass/Fail Criteria (each PEC): PASS ISO Class 5 or better for all samples: less than or equal to 3,520 particles (0.5 micron and larger) per cubic meter FAIL greater than 3,520 particles (0.5 micron and larger) per cubic meter for any sample Viable Air Sampling Citations: USP <797>, USP <1116>, CAG-009-2011 Methods: CAG-009-2011 Locations: One of each bacterial and fungal near the geometric center of the work surface in the LAFW and outside the LAFW. Procedure: All samples shall be collected under dynamic operating conditions by volumetric impaction. Bacterial samples will be collected using 55mm plates containing TSA with neutralizing agents (lecithin and polysorbate 80). Samples will be incubated inverted at 30-35 C for 48-72 hours. Fungal samples will be collected using 55mm plates containing MEA or SDA with neutralizing agents (lecithin and polysorbate 80). Samples will be incubated at 26-30 C for 5-7 days. Colony forming units will be assessed daily and counts will be adjusted per manufacturer MPN calculation or statistical correction factor and reported as CFU per cubic meter. Pass/Fail Criteria: PASS 1CFU per plate and no highly pathogenic organisms FAIL >1 CFU per plate or 1 CFU of highly pathogenic organisms Highly pathogenic organisms defined as gram-negative rods, coagulase-positive staphylococci, molds and yeasts Pass/Fail Criteria (Outside CAI): PASS 100 CFU per plate FAIL >100 CFU per plate Viable Surface Sampling Citations: USP <797>, USP <1116>, CAG-009-2011 Locations: One of each bacterial and fungal near the geometric center of the work surface in the LAFW, and outside the LAFW. Methods: CAG-009-2011 Procedure: All samples shall be collected under dynamic operating conditions using convex agar plates by gently rolling across the surface once in a single direction. Surface to be disinfected by wiping with non-shedding wipe saturated with sterile 70% isopropyl alcohol (provided by facility) immediately after each sample is collected. Bacterial samples will be collected using 55mm plates containing TSA with neutralizing agents (lecithin and polysorbate 80). Samples will be incubated inverted at 30-35 C for 48-72 hours. Fungal samples will be collected using 55mm plates containing MEA or SDA with neutralizing agents (lecithin and polysorbate 80). Samples will be incubated at 26-30 C for 5-7 days. Colony forming units will be assessed daily and reported as CFU per plate. Pass/Fail Criteria (CAI): PASS 3 CFU per plate and no highly pathogenic organisms FAIL >3 CFU per plate or 1 CFU of highly pathogenic organisms Highly pathogenic organisms defined as gram-negative rods, coagulase-positive staphylococci, molds and yeasts Pass/Fail Criteria (Outside CAI): PASS 100 CFU per plate FAIL >100 CFU per plate Temperature and Humidity Tests: Ante Room, I.V. Room, Air Lock, and Chemo Room Purpose: The purpose of these tests is to demonstrate the capability of the system to control temperature uniformity and humidity within buyer-specified limits. Sound Level Tests: Ante Room, I.V. Room, Air Lock, and Chemo Room Purpose: The purpose of this test is to establish the airborne sound pressure levels produced by the basic Cleanroom mechanical and electrical systems as experienced within the room and in adjacent external occupied areas, and to verify that performance meets the Buyer's specifications. Light Level Tests: Ante Room, I.V. Room, Air Lock, and Chemo Room Purpose: The purpose of this test is to verify that the specified lighting levels and uniformity of lighting within the Cleanroom has been met. Room Pressurized Tests: Ante Room, I.V. Room, Air Lock, and Chemo Room Purpose: To verify the capability of the Cleanroom system to maintain the specified pressure differential in the Cleanroom. Locations of all areas and test locations will be required for each individual test. CONFORMANCE STANDARDS All testing of equipment, hoods, and areas shall meet any VHA standards, Joint Commission for Accreditation of Hospital Organization (JCAHO) or National Codes, Controlled Environment Testing Association (CETA) Sterile Compounding Facilities (or equivalent) guidelines, and USP 797/800 standards. HOURS OF WORK The Hood testing and Pharmacy IV clean-room testing will be performed Monday through Friday between the hours of 6:00 am to 4:30pm. Any time changes must be cleared thru the acting COR of the contract. All Federal Holidays are observed Detroit VA Medical Center, and any proposed work during these days must be cleared through the COR or Facilities Maintenance Service Chief. GOVERNMENT RESPONSIBILITIES The Government will provide access to rooms where hoods are located so contractor can perform testing/ certifications. The Government will supply room maps for all areas of work. The COR will provide an escort for Contractor, if needed, to find rooms and locations. G. SAFETY The contractor shall provide all personal protective equipment (PPE) needed for their employees such as safety glasses, hearing protection, safety shoes, gloves and any other PPE. H. REPORTS The contractor shall be responsible for submitting detailed reports within 14 days of completion of each semi-annual inspection, for each type of hood. The report must include the type of hood, ID number, EE number, room number, air flow data and hood pass/fail. The Method of Contractor Selection has not been determined at this Time.

Conceptual

Medical

Public - Federal

Service, Maintenance and Supply

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

Subscribe For Documents

2 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
221
Active Projects
130
Bidding Soon
1,567
All Active Projects
730
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

September 3, 2025

img_map_placeholder

4646 John R St, Detroit, MI

Unlock Efficiency: The Future of Commercial Construction is Data-Driven

Access Now

Get the right
data with Project Intelligence

Share with your network.

RFP - Bio/Fume Hood Testing & Certification

Project Shared

with

example@example.com

Upgrade now for industry‑leading commercial construction data.

You've reached the free-view limit.

Thousands of projects are added every week - don't miss out. Explore the best product options for your business and subscribe today.

Get Access Now

Choose what you would like to do.

Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.