Renovation of a water / sewer project in Bryan, Texas. Completed plans call for the renovation of a water / sewer project.

Project Scope: o Remove the pumping equipment from the well, the Contractor shall inspect the existing pump bowl, column pipe, enclosed oil tubing, line shaft, other pump column assembly components and discharge head and provide a written report for the pump equipment to the Engineer on the condition of the materials and equipment, a list of the material(s) and equipment that need to be replaced or reconditioned and the cause or causes of any failures or damage to the materials. o Perform one video survey and present video and written report of findings (well depth approximately 2,867 feet). o Well Evaluation: Contractor to supply all necessary equipment to set a pump to a 600' setting and produce 3,000 gpm. After an initial water static level, pump test will last for 1 hour with water pumping levels obtained on 15 minute intervals (Bid Alternate Number 1). o Add 160 feet of new column pipe to match existing material. Column shall be ANSI Thread and Coupled 12-inch diameter steel pipe with a 0.375 wall thickness. o Add 160 feet of new line shaft to match existing material. Line shaft shall be machined, ground, and polished precision shafting of ample size to operate the pump without distortion or vibration. Line shaft shall be furnished in interchangeable sections not over 20' in length and shall be coupled with high grade, machined steel couplings. Line shaft shall be 2 3/16-inches in diameter solid shaft. o Add 160 feet of new shaft enclosure tube to match existing material. Shaft enclosing tube shall consist of interchangeable sections not over five-feet (5') in length of Schedule 80 steel pipe to receive bronze couplings which act as line shaft bearings. Tubing shall be 3 1/2-inches in diameter. o Column pipe spacers shall be replaced. Spacers shall be on 10 foot intervals. o Replace all existing bronze couplings which act as line shaft bearings (approximately 100). o Existing fabricated steel discharge head with separate base plate and ANSI Class 125 flanged outlet above ground was rated to carry the maximum down-thrust the electric can provide. Evaluate existing discharge head to ensure it is adequate for additional load of new pump setting. Replace/modify as necessary. o Supply a new, 9 stage Goulds Pump Model 18DMC. o Refurbish the existing 7 stage Goulds Pump Model 18DMC and add 2 additional stages bringing it to a 9 stage pump (spare pump). o Install the new 9 stage Goulds Pump Model 18DMC to a pump setting of 660 feet utilizing the existing 10-foot (10') section of 10-inch (10") diameter suction pipe with accompanying cone strainer connected to the bottom of the bowl assembly. o The deep well shall be equipped with a 1/4-inch (1/4") Dekron coated stainless steel airline, gage and necessary fittings to extend from the surface to the bottom of the column pipe (660'). The airline shall be a continuous line with no fittings. The 4 1/2-inch (4 1/2") diameter gage shall be calibrated to read in feet of H2O. A suitable connection and an air pump shall be furnished for testing the well. o Disinfect the well as per AWWA standards. o Flush the well and collect applicable bacteriological samples (coordinate with City staff). o Final performance test to ensure operational status of equipment. Perform a complete pump test including static and pumping levels, flow rates, motor amperage, and all other information normally checked on a maintenance type pump test on an existing well. Run the pump test for three (3) hours. Include flows and meter readings at: o 0 psi discharge o 10 psi discharge o 40 psi discharge o Show flows by sonic meter or orifice and compare those to magnetic meter installed. In order to ensure a fair and public process, all questions related to this Request for Bids shall be addressed in writing, via the Brazos Valley via Online prior to 10:00 am CST on April 11, 2025. Contact with any City of Bryan employee or official is prohibited without prior written consent from the City Purchasing Supervisor. Failure to observe this requirement may be grounds for rejection of the Bid. Vicki Harris Buyer harrisv@bryantx.gov. o May 27, 2025- Performance and Payment Bonds due within 7 business days of Executed Contract o May, 2025 - Anticipated Pre-Construction Meeting (Date TBD) o June 1, 2025, 2025 - Anticipated date of Notice to Proceed o September 5, 2025 - Targeted Completion Date Question Cuttoff Date & Time 4/21/2025 2:00 PM CT A Performance Bond in the amount of one hundred percent (100%) of the contract price will be required (if the contract exceeds $100,000). A Payment Bond in the amount of one hundred percent (100%) of the contract price will be required (if the contract amount exceeds $50,000).

Award

Water / Sewer

$573,043.00

Public - City

Renovation

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

11

Subscribe For Documents

4 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
369
Active Projects
192
Bidding Soon
3,264
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

April 25, 2025

June 1, 2025

Project location map

To Be Determined, Bryan, TX

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.