BLOCK PAGE!!!
Get Full Details

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Published August 5, 2025 at 8:00 PM

Updated August 6, 2025

Renovation of an educational facility in New York, New York. Completed plans call for the renovation of a educational facility.

Over 4M Roofs/Windows/Exterior Masonry A. This section applies to all work conducted in existing premises. This includes work that may generate dust and debris, work that disturbs painted surfaces assumed or known to be lead-based paint and/or that disturbs ballasts, light bulbs, batteries, Mercury Containing Equipment, electronics or other hazardous materials not specifically covered in other specifications. B. Furnish all labor, materials, equipment, and incidentals required to remove, handle, store, and dispose of all PCB containing and non-PCB containing ballasts, light fixtures, fluorescent bulbs as specified, as shown on the Drawings and Specifications and as directed by the Authority. Work shall be done in accordance with all applicable City, State and Federal laws and regulations and SCA protocols. C. Abate and dispose of all asbestos containing material (ACM) as specified in section 02081, as shown on the Drawings, and as directed by the Authority. Work shall be done in accordance with all applicable City, State and Federal laws and regulations and SCA protocols. D. Architectural and electronics wastes that would otherwise be hazardous waste due to metals (e.g., scrap metal with lead-based paint, computers) may only be recycled if the contractor meets the New York State Department of Environmental Conservation (NYSDEC) hazardous waste recycling regulations (e.g., 6 NYCRR 371.1(c)(7)) notification). The Contractor shall provide all labor, equipment and materials for performance of the Work in accordance with the Contract Documents. E. Unless the Authority provides information regarding the lead content of specific painted surfaces, all interior painted surfaces are assumed to contain leadbased paint. Manage all waste and wastewater as described in Articles 1.28 and 1.29, including determining if it is Toxicity Characteristic (e.g., lead containing) hazardous waste. F. All requirements of this specification that refer to lead-based paint work in 'target spaces' or 'common areas' apply to all work in: 1. 'Target spaces': 1st Grade, Kindergarten, pre-K, LYFE centers, Special Ed (D75) and Pregnant Student Program areas as well as any spaces in which these students visit regularly at least 2 days/week provided that each day's visit lasts at least 3 hours and the combined weekly visits last at least 6 hours, and the combined annual visits last at least 60 hours, and 2. 'Common areas': Those areas routinely used by children under age 6, such as restrooms, cafeterias, auditoriums, gymnasiums, gymatoriums, libraries (but not hallways, stairways, and garages) and the exterior sides of the building that are immediately adjacent to classrooms or common areas for children under 6. G. This section shall be used in conjunction with other Specifications that also apply, notably where building materials contains asbestos or "PCB-containing caulk" containing more than 50 parts per million (ppm) of Polychlorinated Biphenyls (PCBs). 1. Where painted caulk, light fixture or ballast wire insulation or other building materials being removed is also an Asbestos Containing Material (ACM), follow applicable provisions of both Specification 02081 and this specification. 2. Where painted caulk being removed is also a PCBcontaining caulk, follow applicable provisions of both Specification 02082 and this specification. H. Domestic potable water disinfection and testing are required for all projects involving the potable water systems. Assistance in the collection of lead in water samples is also required. For projects involving the potable water system resulting from a change of scope or field modification, consult IEH HazMat for appropriate direction on how to proceed. The plumbing and drainage work of this contract shall include but shall not be limited to the following systems, equipment and services: 1. Remove and replace existing total of eleven (11) roof drains. Four (4) 3" roof drains and seven (7) 4" roof drains. Relocate existing two (2) 4" roof drains to min. 30" from wall or any obstruction. Exact size of roof drains to be verify in field by plumbing contractor. Replace piping from the roof drain up to the first elbow connection or the first pipe section to the existing leader at ceiling below - typical. Repair and paint ceiling below to match with existing condition. (Approximately 30 L.F.). 2. Relocate existing two (2) 4" vent stack to min. 18" from wall or obstruction and min. 10' from HVAC fresh air intake. 3. Provide new 2" area drain in one of the areaways. 4. Remove existing 14" w.c. gas piping from existing gas booster to HVAC gas equipment on roof (Approximately 410 L.F.). Abandon concealed gas piping in place. Provide new gas distribution piping to existing HVAC gas equipment on roof along with gas safety shut off valve, gas riser shut off valve, line pressure regulators, and gas cocks. 5. Piping - General: Piping, piping installation or hook-up shall mean a complete installation in all respects including pipe, fittings, valves, unions, traps, strainers, specialties and other miscellaneous items to make piping systems and equipment operational. 6. Insulation, Painting and Identification: As specified in their respective sections of this Contract. 7. Miscellaneous Work: Included shall be all items of materials, piping, controls, wiring and other miscellaneous items not specifically shown on Contract Drawings or called for herein but which are normally furnished and required for a complete installation of this type. 8. Tests: The Contractor shall perform pressure, performance and operating tests and other tests as hereinafter specified, as directed by the Authority and as required by agencies having jurisdiction as specified in Section 15414 "TESTS". 9. Sealing of Openings: Openings left in walls, floors, ceilings or partitions shall be sealed. Finish shall match existing adjoining finish in all respects.

Award

Educational

$10,711,000.00

Public - City

Renovation

Our team is requesting plans for this project.

Subscribe For Documents

3 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
994
Active Projects
520
Bidding Soon
7,639
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

June 11, 2025

July 12, 2025

Project location map

1180 Rev James A Polite Ave, New York, NY


Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.