Renovation of a mixed-use development in Williamstown, Kentucky. Completed plans call for the renovation of a educational facility.

**As of August 5th, 2025, the project was awarded to C&T Design and Equipment, with an awarded amount of $46,108.40.** Item 1 Walk-in Cooler/Freezer Combo Make: Kolpak Model: A273782 Overall Dimensions: 22'-1 1/2" x 14'-5 1/2" x 8'-6 1/4"(Must Field Verify) Freezer Interior Dimensions: 13'-6" x 13'-9 1/2" x 7'-10 5/8" Walls: 4" Class 1 - Foamed in place Urethane Exterior: Galvalume - Embossed 26 Ga - Except Where Noted Interior: Galvalume - Embossed White 26Ga. Ceiling: 4" Class 1 - Foamed in place Urethane Type: Standard Attachment: Lock Down Exterior: Galvalume - Embossed 26 Ga Interior: Galvalume - Embossed White 26Ga. Floor Application: 4" Class 1 - Foamed in place Urethane Type: Standard 1000# ERA Finish: Aluminium - Diamond Tread .100 Compartment Accessories: 2 ea. Light - LED 48IN 120/230V 50/60HZ 3 ea. Trim Angled 3" x 3" x 8ft Galvalume Embossed White 26 ga 1 ea. Vent - Pressure Relief, Heated Kason 1832 - ALLOWED IN WALLS OR Scientific Doors (Ensure not behind a Masonry Wall) Doors/Openings: Door: 34" x 78" Right Swing Out Recessed 0" with 0" Leveling Sand and 0" Tile & Grout. Frame: Exterior: Galvalume - Embossed White 26Ga. Interior: Galvalume - Embossed White 26Ga. Plug: Exterior: Galvalume - Embossed White 26Ga. Kickplate, Alum .063 Diamond Tread 36" High Interior: Galvalume - Embossed 26 Ga Door/Opening Accessories: 1 ea. Delete Heated Air Vent (from this Door Section) 1 ea. Door Closer - Kason 1094 (STD) 1 ea. Handle - Kason 27C Brushed Chrome 1 ea. Heater Wire, 5 Watt / FT 3 ea. Hinge - Kason 1346 Brushed Chrome Adjustable / Spring Assisted (STD) 1 ea. Light Fixture - Kason 1803 LED w/Bulb, Globe & Nightlight 120V 50/60Hz (STD) 1 ea. Ramp - Interior 34x20 1 ea. Switch Thermometer Combo - Kason 1967-A2, 20ft Lead, 120V 50/60Hz F/C (Weatherproof 1-way) 2.83 lf Threshold, Stainless Steel 14 ga 1 ea. Viewport - 14X14 Freezer, Heated Frame and Glass 4in Thick 120V 50/60HZ Cooler Interior Dimensions: 7'-7 1/2" x 13'-9 1/2" x 7'-10 5/8" Walls: 4" Class 1 - Foamed in place Urethane Exterior: Galvalume - Embossed 26 Ga - Except Where Noted Interior: Galvalume - Embossed White 26Ga. Ceiling: 4" Class 1 - Foamed in place Urethane Type: Standard Attachment: Lock Down Exterior: Galvalume - Embossed 26 Ga Interior: Galvalume - Embossed White 26Ga. Floor Application: 4" Class 1 - Foamed in place Urethane Type: Standard 1000# ERA Finish: Aluminium - Diamond Tread .100 Compartment Accessories: 1 ea. Light - LED 48IN 120/230V 50/60HZ 3 ea. Trim Angled 3" x 3" x 8ft Galvalume Embossed White 26 ga Doors/Openings: Door: 34" x 78" Left Swing Out Recessed 0" with 0" Leveling Sand and 0" Tile & Grout. Frame: Exterior: Galvalume - Embossed White 26Ga. Interior: Galvalume - Embossed White 26Ga. Plug: Exterior: Galvalume - Embossed White 26Ga. Kickplate, Alum .063 Diamond Tread 36" High Interior: Galvalume - Embossed 26 Ga Door/Opening Accessories: 1 ea. Door Closer - Kason 1094 (STD) 1 ea. Handle - Kason 27C Brushed Chrome 1 ea. Heater Wire, 1 Watt / FT 3 ea. Hinge - Kason 1346 Brushed Chrome Adjustable / Spring Assisted (STD) 1 ea. Light Fixture - Kason 1803 LED w/Bulb, Globe & Nightlight 120V 50/60Hz (STD) 1 ea. Ramp - Interior 34x20 1 ea. Switch Thermometer Combo - Kason 1967-A2, 20ft Lead, 120V 50/60Hz F/C (Weatherproof 1-way) 2.83 lf Threshold, Stainless Steel 14 ga 1 ea. Vent - Pressure Relief, Heated 120V 50/60Hz 4/5/6" Thick (STD) 1 ea. Viewport - 14X14 Cooler, Heated Frame 4in Thick 120V 50/60HZ Site visit is required, and it is the responsibility of the bidder to allow for proper air flow around the box per the manufacturer's recommendations. Existing refrigeration systems will be reused on this project; successful bidder will be responsible for pumping down and preserving systems during construction and reinstalled afterwards by a licensed HVAC installer. Demolition, removal and hauling away existing walk-in panels is to be included in bid. If any issue arises with building foundation, the installer must notify Grant Schools immediately before continuing with work. Existing shelving shall be removed during construction and reinstalled afterwards as part of this contract. Electrical disconnects and reconnects are to be included and must be performed by a licensed electrician. Trim panels that extend from walk-in panels to building walls and ceilings are to be included as part of this contract. The sprinkler system will be handled by Grant County Schools.

Award

Educational

$46,108.00

Public - County

Renovation

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

3

Subscribe For Documents

6 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
245
Active Projects
156
Bidding Soon
2,115
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

June 13, 2025

July 28, 2025

Project location map

Multiple Locations, Williamstown, KY

Related To This Project


Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.