Privately Funded
Bidding Soon
Documents Available
Publicly Funded
Addenda Available
Post-Bid
Published November 17, 2025 at 7:00 PM
Updated November 18, 2025
Renovation of a detention facility in Charleston, West Virginia. Completed plans call for the renovation of a detention facility.
The West Virginia Division of Corrections and Rehabilitation (DCR), on behalf of South Central Regional Jail and Correctional Facility (SCRJ&CF), to establish a contract for a lump sum quotation to replace two (2) existing hot water heaters with new. Question Deadline 09/17/2025 at 2:00 PM ET Question Submission Deadline: 1124 Smith Street, Suite 2100 Charleston, WV 25301 Fax: (304) 957-7622 Email: Philip.K.Farley@wv.gov (Email is the preferred method.) FOR INFORMATION CONTACT THE BUYER Philip K Farley (304) 549-1050 philip.k.farley@wv.gov A. At South Central Regional Jail and Correctional Facility, there are two (2) existing hot water heaters located on the mezzanine level, mechanical room C366. On the contract drawings, the two (2) hot water heaters are labeled as the following: Cpod mechanical room C366, GWH5 & GWH-6. The contractor must remove the existing two (2) hot water heaters, install two (2) new hot water heaters, install any required new domestic water piping, install any required new natural gas piping, install new expansion tanks, and install any required new vent piping. Additional information on the project is listed below. B. C-pod mechanical room, C366 new hot water heaters requirements: 1. The new hot water heaters must meet the following requirements and what is stated in specifications section 1.01 or equal: a. Must be a minimum storage of 215 gallons of water. b. The input must be a minimum Btu/h is 199,000 and 58 kW. c. The recovery rate from 40 to 120 degrees Fahrenheit in one hour must be at a minimum of 192 gallons. d. The working pressure (hydrostatic test) is 150 PSI and 1,034 kPa. e. Must operate off natural gas. f. The minimum inlet gas pressure is 4.5" WC / 1,121 Pa. g. The maximum inlet gas pressure is 10.5" WC / 2,616 Pa. h. The manifold gas pressure is 1.4" WC / 349 Pa i. The hot water heaters electric is 120 volts, single phase, 60 hertz, and 5 amps. j. Must be a minimum of 82% thermal efficiency. k. Must be a low NOx water heater. l. The hot water tank interior tank must be a duplex stainless-steel tank.
Award
Jails / Prisons
$217,817.00
Public - State/Provincial
Renovation
Trades Specified
Division 00 - Lorem Ipsum
One Low Price
- One license and one market
- Details and key contacts on all bidding projects
- Organize your pipeline with a digital bid board
- Automatically match opportunities to your profile
- Saved searches deliver daily project leads to your email inbox
Market Pricing Around
- All Starter Product functionality
- Access to all documents (plans, specifications, and addenda)
- Access to planning projects
- Access to contact information
- Ability to Export
Find More Local Projects
Within 75 Miles of This Project
You’ve Reached the Free View Limit
Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.
Come back in [[refresh_days]] to get [[project_count]] more free projects.
September 24, 2025
October 24, 2025
1001 Centre Way, Charleston, WV
Related To This Project
Charleston, WV
Bid Date: Sep 08 2025
Charleston, WV
Bid Date: Sep 10 2025
Charleston, WV
Bid Date: Sep 30 2025
Charleston, WV
Bid Date: Sep 17 2025
Charleston, WV
Bid Date: Nov 18 2025
Charleston, WV
Bid Date: Sep 30 2025
Charleston, WV
Bid Date: Sep 23 2025
Charleston, WV
Bid Date: Sep 24 2025
Charleston, WV
--
Charleston, WV
--
Charleston, WV
Bid Date: Sep 09 2025
Charleston, WV
--
Charleston, WV
Bid Date: Oct 06 2025
Charleston, WV
Bid Date: Sep 09 2025
Charleston, WV
--
Bid Smarter, Not Harder
Spend more time doing the job than looking for it. ConstructConnect has the industry's most complete project data to help you find, bid, and win. Now.
Sign up to get free access, instantly.