Renovation of a fire / police facility in Newberry, South Carolina. Completed plans call for the renovation of a 4,900-square-foot fire / police facility.

As of January 28, 2026, project was awarded to Palmetto Roofing but awarded amount is not available. Cost Range: $75,000 - $95,000 Any questions regarding any aspects of the project scope or the bid should be made in writingto wredfern(g)cityofnewberiy.com. Responses will be emailed in addendum form to the participating contractors. The City of Newberry (the City) requests Lump Sum Bids from qualified contractors to provide all labor and materials for the installation of a mechanically fastened, 60 mil TPO roof system over 1 " polyisocyanurate insulation on the lower roof of the Fire Station at 1041 Wilson Road. This is to be installed in a manner that meets the manufacturer's specifications to achieve a 20-year labor and materials warranty. A more detailed Project Description is as follows: The existing roof system is comprised of simple span barjoists with a metal roof. A spray foam system was installed over this a number of years ago. This has failed and the fire department is experiencing delamination and leakage in numerous locations throughout the roof. It is the intent of this project to install a new 60 mil TPO roof system over the entire area which is roughly 4900 sf. (Images of the site and building are included) An outline of the work included is as follows: Remove/repair spray form as needed to accept the new insulation 2. Replace rusted out metal panels as needed at a unit price listed on the bid 3. Provide and install 1 " polyisocyanurate insulation over spray foam 4. Provide and install polyisocyanurate crickets to divert water as needed 5. Install new roof drains and tie into existing pipe 6. Install plywood sheathing as needed on existing walls to receive polyisocyanurate membrane 7. Provide and install new 60 mil TPO membrane per manufacturer's instructions 8. Provide and install flashing and counterflashing at roof drains, pipes, equipment connections, and walls 9. Provide and install 24 ga. pre-finished coping and perimeter edge seal in manufacturer's standard colors This scope involves the repair of a 4900sf roof that was originally a metal roof over bar joists. A foam coating was applied over 10 years ago that has failed. This scope will involve modifying the foam to accept a 1" polyisocyanurate foam layer and a mechanically fastened 60 mil TPO membrane to meet manufacturers specifications to achieve a 20-year labor and material warranty. *The value for this project is based on a financial range. The value is listed as the highest possible cost from the range provided by a stakeholder or official project document.

Award

Fire / Police

$95,000.00

Public - City

Renovation

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

3

Subscribe For Documents

3 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
69
Active Projects
7
Bidding Soon
1,161
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

November 4, 2025

December 1, 2025

Project location map

1041 Wilson Rd, Newberry, SC

Related To This Project


Recently Viewed

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.