Published March 11, 2026 at 8:00 PM

Updated March 12, 2026

This is a service / maintenance or supply contract in Clarksburg, West Virginia. Contact the soliciting agency for additional information.

Monthly, annual, and triennial testing, inspection, and emergency repair services are required to ensure the generator systems remain compliant with the most recent VHA-adopted NFPA 110 standards and fully prepared for TJC and OIG inspections. Services include providing all labor, materials, tools, and equipment to conduct monthly 30-minute operational tests under facility load, verifying time-to-transfer performance within 10 seconds, and rotating the initiating ATS each month to ensure all switches are cycled annually. When generators fail to reach 30% load or required exhaust temperature, supplemental load bank testing must be performed in accordance with NFPA 110 Section 8.4.2, including an annual 2-hour load-bank exercise reaching at least 75% of the nameplate rating. A triennial 4-hour test is required, maintaining at least 30% load for the first three hours and at least 75% for the final hour, using a load bank if necessary. Emergency repair support must be available 24/7/365 with a maximum on-site response time of two hours. Each emergency repair must produce Return-to-Service documentation identifying the cause and confirming that the applicable NFPA 110 re-test has been completed. All documentation must meet TJC and OIG audit standards and be submitted within 72 hours. Reports must include kW, amperage, hertz, exhaust temperatures, fuel level, oil pressure, coolant temperature, voltage, frequency, and battery diagnostic data. Each report must include a signed certification that all testing met the most recent VHA/NFPA 110 criteria. Technicians must be EGSA-certified or factory-trained for the specific VAMC equipment, and all work must comply with current NFPA 70E safety requirements, including proper arc-flash PPE and safe-work-zone establishment. The contractor must maintain generator test records for at least three years, in electronic or hard-copy form, and ensure compliance with NFPA 110 data retention requirements. Services cover five generators ranging from 128 kVA to 1250 kVA across multiple buildings and locations. Location: Louis A. Johnson VA Medical Center, 1 Medical Center Drive, Clarksburg, WV 26301 The Method of Contractor Selection has not been determined at this Time.

Conceptual

Medical

Public - Federal

Service, Maintenance and Supply

We’ve obtained documents for this project and are currently processing them.

Subscribe For Documents

2 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
38
Active Projects
9
Bidding Soon
513
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

March 22, 2027

Project location map

1 Med Center Dr, Clarksburg, WV


Recently Viewed

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.