BLOCK PAGE!!!

Get Full Details

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Saving Project...

Published May 13, 2026 at 8:00 PM

Updated May 15, 2026

Site work and paving for a transportation facility in Ocala, Florida. Completed plans call for site work for a transportation facility; and for paving for a transportation facility.

1. The City of Ocala requires the services of an experienced contractor to complete the construction of Ocala International Airport (OCF) Runway 36 RSA Grading. The scope of the project consists of furnishing all labor, materials, equipment, supervision, and incidentals necessary to complete the Runway 36 Runway Safety Area (RSA) Grading Project at Ocala International Airport (OCF) in accordance with the Contract Documents. The primary objective of the project is to regrade the Runway 36 RSA to meet current Federal Aviation Administration (FAA) design standards. Work includes site preparation, demolition, earthwork, grading, material reuse, and site restoration. The Contractor shall remove the existing gravel service road, strip and stockpile topsoil, and salvage suitable aggregate for reuse. Reusable materials shall be stockpiled and protected in accordance with the Contract Documents. Earthwork operations shall include excavation, placement of approved fill, and fine grading to achieve the design elevations and slopes. Fill material shall consist of approved AASHTO A-3 material or equal and shall be placed and compacted in accordance with specifications. The finished RSA shall be stable and compliant with FAA requirements. Additionally, the Contractor shall reinstall the salvaged gravel service road for final restoration, including placement of topsoil, finish grading, and sodding of disturbed areas. The Work includes protection and modification of existing airfield infrastructure, including utilities, lighting systems, and NAVAIDS. The Contractor shall adjust the elevations of select Medium Intensity Approach Lighting System with Runway Alignment Indicator Lights (MALSR) to accommodate the proposed grading as shown on the engineering plans. The Contractor shall coordinate with a concurrent FAA project for the installation of conduits and associated infrastructure serving FAA utilities within or adjacent to the project limits. This coordination shall include scheduling and sequencing, of construction operations. All work shall be performed within the Air Operations Area (AOA) in accordance with the approved Construction Safety and Phasing Plan (CSPP). The Contractor shall comply with all safety, security, and operational requirements, including access control, haul routes, and Foreign Object Debris (FOD) management. Work will be performed in a single phase during nighttime hours and will require temporary runway closures. The Contractor shall coordinate closures with the Owner and support issuance of Notices to Air Missions (NOTAMs). The Contractor shall provide and maintain all temporary safety measures, including barricades, warning devices, and lighted "X" runway closure markers, and shall maintain a clean and safe work environment throughout the project. Upon completion, all disturbed areas shall be restored and the site left in a condition acceptable to the Owner and Engineer. 2. Badging of individuals in supervisory positions will be required. Allow 2 hours for the badging process. There is no cost for the badges. LICENSING, EXPERIENCE AND REFERENCES REQUIREMENTS: 1. Licensing Requirement: Bidder must be a licensed General Contractor in the State of Florida to submit a bid for this project. Proof of valid licensing per Florida Department of Business and Professional Regulations will be verified. 2. Experience Requirement: Bidder must possess a minimum of 5 years' experience in providing commercial/industrial building construction services. Bidders must provide three (3) work projects completed within this timeframe with bid submission. 3. References Requirement: Contractor must provide three (3) verifiable professional references. PRICING AND AWARD 1. Bids will be received on a Unit Price basis. The City will pay the Contractor only for the actual units that the Contractor provides, installs, or constructs. 2. Award will be made to the lowest bidder whose pricing has the lowest total cost for the project. 3. Bidder will honor prices for One Eighty Twenty (180) days after award of solicitation. 4. Awarded Vendors shall comply with all applicable provisions of Section 787.06, Florida Statutes. Specifically, all non-governmental Vendors shall provide the City of Ocala with an affidavit signed by an officer or a representative under penalty of perjury attesting that the non-governmental entity does not use coercion for labor or services as defined in Section 786.06(2), Florida Statutes). 5. AMOUNTS DUE TO THE CITY. Contractor/Vendor must be current and remain current in all obligations due to the City during the performance of services under the Agreement. Payments to Contractor/Vendor may be offset by any delinquent amounts due to the City or fees and/or charges owed to the City. The requirements for this listing are outlined in the exhibits. Bid security equal to five percent (5%) of the total bid must accompany each Bid. Formal Question Due By: 5/20/2026 @ 5:00 PM EST Contact Name: Ms. Eileen Marquez Contact Email: emarquez@ocalafl.gov Contact Phone: (352) 629-8362

GC Bidding

Transportation Terminals

$400,000.00

Public - City

Paving, Site Work

24

14

2

Subscribe For Documents

5 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
250
Active Projects
97
Bidding Soon
1,374
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

May 26, 2026

June 25, 2026

Project location map

1770 SW 60th Ave, Ocala, FL

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.