Get Full Details

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Saving Project...

Published September 28, 2026 at 8:00 PM

Updated October 4, 2026

Site work and renovation of a medical facility in Kaneohe, Hawaii. Completed plans call for the renovation of a medical facility.

Purchase and installation of fencing to enclose the garden area on the grounds of Hawaii State Hospital. Scope of Work: Building a 6-foot (6') tall fencing to be pig/hog proof around 1,700 feet of perimeters . No machines can be used for work as it will destroy the lo'i in the garden area. Perimeter line will need to be cleared by hand. A. Line posts shall be seven-foot (7') Galvanize T-post, to be installed to a depth of no less than thirty inches (30") below ground. B. Fence Fabric will be 1348 hog fence, double dipped galvanized, or an approved similar product. The fence shall maintain a clearance of no more than one inch ( 1 ") above the ground. Any section exceeding one inch (1 ") shall be secured using anchored T-posts; if this does not adequately reduce the gap, the area shall be skirted. C. Skirt Fabric will be two-foot (2') in height and shall overlap the main fence by a minimum of two (2) rectangles. The overlap shall be secured using heavy-duty hog rings at every vertical and horizontal intersection where the fabrics meet. The tail end of the skirt shall be secured using anchored T-posts, fastened with nine-gauge (9-ga) wire, and driven flush into the ground at intervals not to exceed five feet (5'). D. Boss Posts will be four inches (4") in diameter and seven feet (7') in height. Posts shall be installed at intervals of fifty feet (50') and set in concrete at a minimum depth of thirty inches (30"). E. Turn Posts will be used for any realignment of the fence. Any realignment of fence greater than twenty degrees (20) will be cut and tied off into the Brace and reattached to a new brace to accommodate the change of direction greater than twenty (20 degrees). All posts shall be installed at a depth of no less than thirty inches (30") below ground. F. Gate posts shall be five to six inches (5"-6") in diameter, constructed using VR concrete posts, and installed no less than thirty inches (30") below ground. G. Gate opening shall be twelve feet (12'). Gates shall be constructed using no less than one and threeeighths inch ( 1 3/8") galvanized Schedule 40 pipe, with a two-inch by four-inch (2" x 4") galvanized wire mesh covering the opening. The opening will consist of two (2) gates, each six feet (6') wide, for a total gate span of twelve feet (12'). H. All labor and materials necessary to complete the work as specified shall be included in the contractor's scope and pricing

Post-Bid

$150,000.00

Public - State/Provincial

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

Subscribe For Documents

No Data

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
57
Active Projects
9
Bidding Soon
329
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

September 25, 2026

October 1, 2026

Project location map

45-710 Keaahala Rd, Kaneohe, HI


Recently Viewed

Get Started

Unlock the Full Project List

Access every active project near you — get started today.

  • 825,000+ active commercial projects tracked daily
  • Verified contact info for the GC, owner, and architect
  • New leads delivered to your inbox every morning
Get Access

Create your account to get started.

Takes less than a minute — no credit card needed