Renovation of a mixed-use development in Northport, New York. Completed plans call for the renovation of a laboratory facility.
This amendment clarifies section 10, first page, first paragraph of the solicitation. This project is for Electrical Power Upgrade NOT for Upgrade HVAC System. Upgrade HVAC System is a typo and therefore shall not be considered. Can Panel CL1-D3 back box remain in the wall for use as a junction box for circuits being refed by new panel CL1-D4 A new blank cover would be provided and painted to match finish on wall. Answer: No, the panel CL1-D3 will be removed completely including back box and main feeder cable and conduit. Do you have a sign in sheet you can provide from the site visit Answer: See site visit sign-in sheet attached to this amendment. Response date has been extended to May 26, 2022, 1:00 PM EST. PROJECT No. 632-21-122 Furnish all necessary professional Construction services to provide complete scope of work to Upgrade the Electrical Power for new Laboratory Equipment at Pathology Laboratory on Building 200, Northport VA Medical Center; 79 Middleville Road, Northport, NY 11768 in accordance with the project drawings, specifications and scope of work. SCOPE OF WORK This project is to provide power supply to new laboratory equipment based on the electrical power study on existing electrical panelboards inside the Laboratory. The electrical power study for existing electrical system for this laboratory had been completed and report had been submitted and approved for this construction project. Scope of work includes but is not limited to the following: o Disconnect and remove existing panelboards 'CL1-D3' and 'CL1-D3B'. o Provide new 120/208V, 3 Phase, 4 Wire, 84 pole panelboards 'CL1-D4'. o Provide new receptacles and branch circuit wirings for new laboratory equipment. o Provide new branch circuit wiring to existing wiremold/receptacles fed from removing panelboard 'CL1-D3'. o All field work shall be performed on and off-hours without disturbing existing equipment in active 24/7 operation of the Lab. Lab operations are not to be interrupted during field work. o Contractor shall carefully coordinate with Laboratory Manager any scheduled/approved circuit outages in advance of any work that would affect Lab operations. o Provide all necessary tools, equipment, and Personal Protective Equipment (PPE) to perform the work safely, effectively, and timely. Tools, equipment, and PPE shall comply with the requirements of OSHA Standard 29 CFR 1910, Subpart I, VA Safety Requirement and NFPA 70E. o All work performance shall comply with VA specifications Section 01 00 00 General Requirement and Section 01 35 26 Safety Requirements on PG-18-1 on https://www.cfm.va.gov/til/ o Contractor shall visit the facility and familiarize themselves with the areas of work before submitting a bid SCHEDULES o Project timeline is 180 calendar days from the Notice To Proceed for field installation services. Project 632-21-122 - Electrical Power Upgrade for New Lab Equipment - Northport VAMC IFB#: 36C24222B0033 BID PRICING SHEET Bids providing less that 120 Calendar Days of Government Acceptance after the date bids are due will not be considered and will be rejected. The bidder agrees to perform the work required at the prices specified below in strict accordance with the terms of the solicitation, if this bid is accepted by the Government in writing within 120 calendar days after the date bidders are due. INFORMATION SECURITY This procurement does not involve VA sensitive information/data. Questions / Request for Information - To preserve the integrity of the procurement process, all questions and request for information must be submitted in writing to Delfo Saco-mizhquiri, Administrative Contracting Officer, by email at Delfo.Saco-mizhquiri@va.gov. EMAIL SUBJECT LINE: RFI Project No. 632-21-122. Questions must be received no later than Friday, May 6, 2022, 4:00 PM EST. *The value for this project is based on a financial range. The value is listed as the highest possible cost from the range provided by a stakeholder or official project document.
Post-Bid
Laboratories
$250,000.00
Public - Federal
Renovation
Trades Specified
Division 00 - Lorem Ipsum
Find More Local Projects
Within 75 Miles of This Project
One Low Price
- One license and one market
- Details and key contacts on all bidding projects
- Organize your pipeline with a digital bid board
- Automatically match opportunities to your profile
- Saved searches deliver daily project leads to your email inbox
Market Pricing Around
- All Starter Product functionality
- Access to all documents (plans, specifications, and addenda)
- Access to planning projects
- Access to contact information
- Ability to Export
You’ve Reached the Free View Limit
Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.
Come back in [[refresh_days]] to get [[project_count]] more free projects.
May 26, 2022
June 27, 2022
79 Middleville Rd, Northport, NY
Related To This Project
Northport, NY
--
Northport, NY
Bid Date: Aug 09 2022
Northport, NY
Bid Date: Sep 02 2021
Northport, NY
--
Northport, NY
Bid Date: Jun 14 2022
Northport, NY
Bid Date: Mar 11 2022
Northport, NY
Bid Date: Jul 12 2021
Northport, NY
Bid Date: Apr 09 2020
Northport, NY
--
Northport, NY
--
Northport, NY
--
Northport, NY
Bid Date: Mar 23 2023
Northport, NY
Bid Date: Dec 15 2022
Recently Viewed
--
--
--
--
--
--
--
--
--
--
The data you need to build the relationships you want. Try it free.
Sign up now to get free company and project data. No payment required.
Get the right
data with Project Intelligence
Project Shared
with
example@example.com
Choose what you would like to do.
Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.
What is your business type?
We have a wide variety of products that are purpose built for certain business types.