Privately Funded
Bidding Soon
Documents Available
Publicly Funded
Addenda Available
Post-Bid
Saving Project...
Renovation of a water / sewer project in Salisbury, Maryland. Working plans call for the renovation of a water / sewer project.
**As of December 21, 2021, the project was canceled.** The City of Salisbury is soliciting proposals for repainting its Paleo Ground Storage Tank (Concrete Tank) exterior only, which is a circa 2010 above ground water tank. This tank is 27' tall with a nominal diameter of 82'-11''; with an exterior Valve vault area that is 26'x16'x16'. The overall capacity of the tank is 1,000,000 gallons. The repainting work to be performed at this time is the removal of existing paint and proper surface preparation prior to application of a protective coating to the exterior surfaces only in accordance with the Manufactures Painting Instructions (MPI Bid Item 100 Exterior painting: 1. Mobilization / Demobilization 2. The Concrete ground storage tank exterior is 27' tall with a nominal diameter of 82'-11''. 3. The Concrete Valve vault exterior area is 26'x16'x16'. 4. Contract drawings have been provided to assist prospective vendors. 5. Scaffolding is permitted around the tank. 6. Prepare a Site-Specific Safety Plan for review by the Department of Infrastructure & Development Department (D.I.D.) and revise in accordance with comments provided. 7. Air Compressor's used must be Blotter tested and be in Acceptance with criteria outlined in ASTM D4285. 8. Spraying with approved apparatus may be substituted for roller or brush application in the locations as indicated by the coating manufacturer. 9. Prior to application of the protective coatings the surfaces are to be cleaned and prepared as specified by the MPI. 10. The existing exterior paint coating on the concrete tank to be removed is Sikagard 62. This is a 2-component, 100% solids, moisture-tolerant epoxy resin. 11. All paint shall be carefully applied per the MPI until a smooth even coating results without runs or sagging. 12. The interior of the tank, exterior concrete roof, exterior 20'' overflow PVC pipe with brackets, and the 18''x24'' Galvanized Elliptical Manway are not included in this scope of services. 13. Concrete Exterior Surfaces - a. Surface preparation and overspray protection are inherent to prices bid, b. Surface Preparation: SSPC-SP13/NACE 6 Minimum- CSP #5 Mortar/#2-3 Coatings, c. Filler: Sherwin-Williams Paint Co. Steel Seam FT 910 or equivalent as warranted to fill cracks, misc. holes, pull outs, air pockets, and other voids not wider than 3 inches as warranted by product specifications, d. Primer: Sherwin-Williams Paint Co. Loxon Concrete & Masonry Primer or equivalent @ 2.1-3.2 Mils DFT, e. 2 nd coat: Sherwin-Williams Paint Co. Loxon XP or equivalent @ 6.6- 8.4 Mils DFT, f. Finish: Sherwin-Williams Paint Co. Loxon XP or equivalent @ 6.6- 8.4 Mils DFT, g. Tank exterior area color shall be Tan. h. Valve vault exterior area color shall be Tan. 14. Metal Exterior Surfacesa. Surface preparation, media blast containment, clean up and disposal of media blast material, and overspray protection are inherent to prices bid, b. Surface preparation: Perform at minimum in accordance with SSPC SP6 Commercial Blast Cleaning Method, c. Primer: Sherwin-Williams Paint Co. Pro Industrial Pro-Cryl Primer or equivalent (1-coat), d. Stripe Coat: Sherwin-Williams Paint Co. Loxon XP or equivalent (2 coats), e. Stripe Coats are to be applied to all welds, outside angles, and sharp edges, f. Stripe mils DFT are not included in the minimum mils DFT per system. g. Ensure that the Door and Door Jamb after repainting close and open smoothly with no abrasions occurring, h. Finish: Sherwin-Williams Paint Co. Loxon XP or equivalent (2 coats), i. Door color is to be: Red, j. Door Jamb color is to be: Black, k. Two (2) Exterior Access Ladders are to be colored: Safety Yellow. One ladder is for the "Exterior Ladder with walk through" for the valve vault roof area access (Height is approximately 19') and the other is "Exterior Ladder with safety climb system and safety cage" for the tank roof area access (Height is approximately 29') l. Safety rail (on top of the tank) is to be colored: Safety Yellow, RESPONSE DUE: December 8, 2021 at 2:30 P.M. (local time)
Final Planning
Water / Sewer
$116,597.00
Public - City
Renovation
Trades Specified
Division 00 - Lorem Ipsum
Find More Local Projects
Within 75 Miles of This Project
One Low Price
- One license and one market
- Details and key contacts on all bidding projects
- Organize your pipeline with a digital bid board
- Automatically match opportunities to your profile
- Saved searches deliver daily project leads to your email inbox
Market Pricing Around
- All Starter Product functionality
- Access to all documents (plans, specifications, and addenda)
- Access to planning projects
- Access to contact information
- Ability to Export
You’ve Reached the Free View Limit
Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.
Come back in [[refresh_days]] to get [[project_count]] more free projects.
December 8, 2021
June 21, 2022
To Be Determined, Salisbury, MD
Related To This Project
Salisbury, MD
Bid Date: Aug 27 2020
Salisbury, MD
Bid Date: Jul 11 2022
Salisbury, MD
Bid Date: Jul 14 2022
Salisbury, MD
Bid Date: Jul 12 2022
Salisbury, MD
Bid Date: May 11 2022
Recently Viewed
--
--
--
--
--
--
--
--
--
--
The best commercial construction data available. Period.
Sign up now to get instant access to project search, five projects and five companies, free.
Get the right
data with Project Intelligence
Project Shared
with
example@example.com
Choose what you would like to do.
Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.
What is your business type?
We have a wide variety of products that are purpose built for certain business types.