BLOCK PAGE!!!

Subscribe For Access

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Saving Project...

Make some green this Black Friday.

Subscribe for the Commercial Construction data you need to get and stay ahead of the competition.

Renovation of a municipal facility in Tampa, Florida. Working plans call for the renovation of a municipal facility.

**As of December 10 2021 the project will be rebid due to no bids received.** The Florida Department of Transportation requests competitive sealed bids (as indicated in the solicitation) for the procurement of dry chemical fire suppression system replacement for District 7 headquarters. Please direct all questions to: Enrique Garcia Phone: (813) 975-6156 FAX: (813) 975-6473 11201 North McKinley Drive Procurement Office MS 7-700 Tampa FL, 33612-6456 Email: enrique.garcia@dot.state.fl.us Any person with a disability requiring special accommodations at the pre-solicitation conference and/or bid/proposal opening shall contact purchasing at the phone number above at least five (5) working days prior to the event. If you are hearing or speech impaired, please contact this office by using the Florida Relay Services which can be reached at 1 (800) 955-8771 (TDD). The Department reserves the right to reject any and all bids or accept minor irregularities in the best interest of the State of Florida. Certified Business Enterprises are encouraged to participate in the solicitation process. The Florida Department of Transportation (FDOT), District 7, seeks the complete services of a qualified Vendor for replacement of the existing dry chemical agent fire suppression system located in the Office of Information Technology (OIT)server/phone switch room of its headquarters building. District 7 headquarters building is located at 11201 North McKinley Drive, Tampa, Florida 33612.The Vendor shall provide a turnkey solution that meets the following requirements: Install a FM200 dry chemical fire suppression system for complete fire protection of the following rooms: Work Location: OIT Suite B400 1. OIT Setup Room-B411. 2. OIT Server Room-B412. 3. OIT Room-B413 The Vendor shall provide and install all necessary components for the replacement, modifications and pressure testing of new piping, fittings and all assemblies associated with the installation, to include but not limited to the following: 1. The major components of the system shall be United Laboratories (UL) listed and Factory Mutual (FM) approved. 2. Sufficient agent cylinders to contain the required amount of extinguishing agent. 3. Suitable safeguards shall be provided to ensure prompt evacuation and prevent entry into hazardous atmospheres. Safety signage, evacuation plans, discharge alarms, training, supervised system lockout valves, pneumatic pre-discharge alarms, pneumatic time delays and warning signs. 4. Adequate mounting brackets for the cylinder(s). 5. Necessary piping, fittings, nozzles, clips and supports. 6. Electric control heads to activate the cylinders. 7. A recessed electrical panel to monitor system status and provide required functions. 8. Battery and charger rated for 24-hour standby plus five minutes of alarm power. 9. Means of manual activation using a pull station. 10. Means of automatic activation using (smoke and/or heat) detectors. 11. A manual means to temporarily abort the system shall be provided. 12. The system shall provide audible appliances/devices to indicate detector activation. . 13. Relay contacts shall be provided within the control panel for the following: damper controls and any equipment shutdowns. . 14. Vendor is responsible for requesting any testing through the State Fire Marshal office before, during and after installation of system and ensure that the provided system passes all inspections. 15. All electrical services and materials shall be provided by the Vendor to include but not limited to: a. 120 Volts power to FM200 control panel. b. Interlock wiring and conduit for shutdown of Heating Ventilation Air Conditioning (HVAC), dampers and/or electric power supplies, relays, or shunt trip breakers. c. Connection to local/remote fire alarm system, listed central alarm station(s). d. The newly installed equipment shall meet all National Fire Protection Association (NFPA) Codes, state, local codes, and manufacturer's requirements.

Final Planning

Municipal

$75,000.00

Public - State/Provincial

Renovation

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

5

Subscribe For Documents

2 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
117
Active Projects
66
Bidding Soon
1,285
All Active Projects
490
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

December 7, 2021

June 10, 2022

img_map_placeholder

11201 McKinley Dr, Tampa, FL


The data you need to build the relationships you want. Try it free.

Access Now

Get the right
data with Project Intelligence

Share with your network.

Project Shared

with

example@example.com

Upgrade now for industry‑leading commercial construction data.

You've reached the free-view limit.

Thousands of projects are added every week - don't miss out. Explore the best product options for your business and subscribe today.

Get Access Now

Choose what you would like to do.

Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.