BLOCK PAGE!!!

Subscribe For Access

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Saving Project...

Renovation of a military facility in Bridgeport, Washington. Completed plans call for the renovation of a military facility.

Contractor Awarded Name: LANTERRA LLC Contractor Awarded Address: Houston, TX 77035-6517 USA Base and All Options Value (Total Contract Value): $111,500.00 Prohibition on contracting with entities engaging in certain activities or transactions relating to Iran. (1) The offeror shall email questions concerning sensitive technology to the Department of State at CISADA106@state.gov. STATEMENT OF WORK Chief Joseph Dam Warehouse Garage HVAC System(s) Bridgeport, WA 1. Provide all materials and labor for installation of 2 x identical packaged, self-contained, outdoor, multi-stage HVAC systems with economizer mixing boxes, for each unit: Air conditioning with resistive heating elements. (Heat Pump alternative not acceptable) 480VAC, 60 Hz power source a) Include appropriately sized disconnects, and all wiring from disconnects to units. b) Source power will be provided to within 6 feet of disconnect locations. At least 12.5 tons cooling capacity, and no more than 20 tons cooling capacity. At least 45 kW resistive heating, and no more than 120 kW resistive heating. Provide economizing mixing box that admits controlled amounts of outside air as makeup and for exhausting internal air. a) Capable of providing at least 600 CFM of outdoor make up air. b) Makeup air much be conditioned. c) Include bird screens as necessary at outdoor intakes/louvers. 12 SEER efficiency or better. Compressors shall be hermetically sealed. Packaged units shall be waterproof, frame mounted, and ready for power connection. a) Must be anchored and secured to ground. b) Must be located at building floor elevation. (See Fig. 2 and 3) Standard size and grade of filter on inlet of return duct. Exact location of units and related equipment at approval of Government. 2. Provide all materials and labor for installation of duct work for #1 above, following requirements are for each unit: Furnish all ductwork, piping offsets, fittings, and accessories as required to provide a complete installation. Installation between outdoor units and indoor ductwork will occur through removal of existing glazing. Glazing, core drills, and other modifications to the structure are subject to approval of the government Install main duct header. a) Attach to building rafters at ~20 feet high, with minimum clearance of no less than 16 feet high. b) Run from packaged unit to end of zone, ~so feet horizontally. c) Reduce size of header as necessary to maintain diffuser velocity. Install diffusers. a) Must spread and throw as required for intended performance b) No less than 8 diffusers and no more than 16 diffusers c) Can be branched or direct connected to header 3. Provide DOC system capable of standalone control of both units from a single controller. Must be capable of fully automatic operation of both units from a single display. Must have 2 discrete temperature inputs. Provide comprehensive control and wiring schematics for O&M use. Must use either BACnet or LonWorks protocols. Must have local display panel. Must have appropriate 1/0 to operate each system. W912DW23R0018 Page 5 of 47 a) Outside air temp b) Return air temp c) Filter differential high limit d) Heating discharge temp low limit (alarm) e) Supply air temp f) Zone thermostat g) Zone Occupancy sensor h) Zone Occupancy sensor over-ride i) Other points as required by system or manufacturer 4. Remove and dispose of existing equipment. 4 x 5-ton Trane compressor condenser units (Located outside on steel frame, See Figure(s) 1, 2, and 4). 4 x 5-ton Trane air handling units/evaporators (Located inside at rafter elevation, See Figure(s) 1, 5, and 6). All existing control systems and refrigerant piping. Bollards to remain in place, located ~12 feet from building at North-East corner (See Figure 1). Location: USACE Corps of Engineers Chief Joseph Dam Highway 17 and Pearl Hill Road Bridgeport, WA 98813-1120 Point(s) of Contact: James Balken Phone: (509) 449-5720 email - james.g.balken@usace.army.mil Scott Bennett Phone: (509) 679-4256

Award

Military

$300,000.00

Public - Federal

Renovation

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

3

Subscribe For Documents

6 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
11
Active Projects
4
Bidding Soon
72
All Active Projects
22
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

April 6, 2023

May 8, 2023

img_map_placeholder

WA-17 & Pearl Hill Rd NE, Bridgeport, WA


The data you need to build the relationships you want. Try it free.

Access Now

Get the right
data with Project Intelligence

Share with your network.

Project Shared

with

example@example.com

Upgrade now for industry‑leading commercial construction data.

You've reached the free-view limit.

Thousands of projects are added every week - don't miss out. Explore the best product options for your business and subscribe today.

Get Access Now

Choose what you would like to do.

Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.