BLOCK PAGE!!!

Subscribe For Access

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Saving Project...

Renovation of a medical facility in Fort Meade, South Dakota. Conceptual plans call for the renovation of a medical facility.

This is a PRE-SOLICITATION SOURCES SOUGHT NOTICE only. No proposals are being requested or accepted with this notice. THIS IS NOT A SOLICITATION FOR PROPOSALS OR PRICING AND NO CONTRACT SHALL BE AWARDED FROM THIS NOTICE. This notice shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs. Responses to this notice will be treated only as information for the Government to consider as part of their market research efforts. The information provided will be used by the Government in developing its acquisition strategy regarding possible set aside for Veteran Owned and other socio-economic categories of small business. Interested parties are responsible for adequately marking proprietary, restricted or competition sensitive information contained in their response. The Government does not intend to pay for the information submitted in response to this notice and parties responding will not be entitled to payment for direct or indirect costs incurred in responding to this notice. The North American Industry Classification System (NAICS) code for this requirement is 811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance, with an SBA Small Business Size Standard of $12.5 million. 1. Please identify any of your firm s existing contract vehicles (e.g., GSA federal supply schedules) which provide similar services as those described in the Statement of Work (attached). 2. Please provide all social-economic categories of your firm (e.g., SDVOSB, VOSB, WOSB, Large Business, 8a, etc.) as well as your firm s SAM Unique Entity ID number (replaces DUNS number) and Government Contract POC. All questions and responses must be submitted via email, no phone calls will be accepted. Please note Black Hills Emergency Generator Repair in the subject line of your response. See attached draft Statement of Work for details of the requirement. Emergency Generator Repair Services STATEMENT OF WORK Hot Springs VA Medical Center 500 N. 5th St. Hot Springs, SD 57747 Statement of Purpose: The purpose of this solicitation is to establish a one-time repair services agreement through a qualified, capable, and regionally located contractor. Repair services for four (4) fixed emergency standby Generators are required at the Hot Springs VA Medical Center, Hot Springs, SD. Approved vendor agrees to administer the proposed objectives pursuant to the terms of this Statement of Work and in the proposal submitted by Department of Veterans Affairs Black Hills Health Care System. Goals of the Agreement: Contractor will provide complete repair services to each of the four (4) Emergency Generators specified in this statement of work for the identified deficiencies as detailed. Contractor will coordinate with VA Maintenance Foreman / Contracting Officers Representative (COR) and VA Electricians, to assist in connecting temporary generator to the transfer switch. Provide and connect one (1) temporary backup Generator to provide power to the applicable building transfer switch during oil pan removals for Buildings 10 and 12 Gensets, respectively. Contractor and VA Electricians will work in conjunction to test and verify that each generator functions properly upon completion of repairs. Contractor will coordinate with VA Maintenance Foreman / COR in an expedient fashion, in order for commencement of this service to occur no later than 45 calendar days from contract award. Description of Services Required: Generator 1, Building 10: Provide and connect temporary backup Generator for Building emergency power capability Replace Oil Pan Replace Oil Pan Gasket Replace Oil Filter Fill Oil to proper level Flush and fill Coolant and verify proper concentration 1 Generator 2, Building 12: Provide and connect temporary backup Generator for Building emergency power capability Replace Oil Pan Gasket Replace Oil Filter Fill Oil to proper level Provide Fuel Polishing Services to the Generator Diesel Fuel Tank Flush and fill coolant and verify proper concentration Generator 3, Building 18: Replace all coolant hoses and clamps Replace the block heater hoses and clamps Replace the fuel flex hose Replace all aftercooler hoses and clamps Replace the radiator cap and seal Replace the fan V-belt Replace the thermostat and seals Replace the alternator belt Flush and fill coolant and verify proper concentration Generator 4, Building 66: Replace the water pump kit Replace all radiator hoses and clamps Flush and fill coolant and verify proper concentration Replace thermostat and seals Replace the exhaust pipe (flex) Replace the fan v-belt, ribbed Contractor Requirements: Contractor will provide all labor, equipment, materials, and travel to perform the service. Contractor will coordinate with VA Maintenance Foreman / COR, to schedule the date and time of service. VA Business hours are Monday through Friday, 8:00am to 4:30pm, excluding federal holidays. Should after-hours or weekend work be required to complete a generator repair to restore operational capability, the contractor will inform the VA Maintenance Foreman / COR with as much advance notice as possible. Contractor will resolve persistent issues related to the Generator repairs as quickly as possible to restore operational capabilities of each Generator. The contractor will inform the VA Maintenance Foreman / COR of any unforeseen generator discrepancies identified during the performance of this service. A decision whether to authorize additional repairs will be made by the VA contracting officer. Notification of the decision will be given to the service contractor as promptly as possible. 2 The contractor is required to receive VA authorization prior to performing any additional repair services which are not described in this Statement of Work. VABHHCS will not be responsible for paying invoices for unauthorized work beyond the scope of this contract. Contractor will work with the VA COR and VA Electricians to create a basic job plan and basic VA safety discussions prior to commencement of work on each Generator as they pertain to policy and other facility requirements. All Contractor staff will wear all appropriate Personal Protective Equipment (PPE) for the task being performed while on VA property. Contractor will follow all National Electric Code, NFPA and OSHA requirements as they apply during performance of this service. Contractor will clean up all service-associated debris, materials, and spills, properly disposing these items off of VA facility property in accordance with state law. Contractor will provide the VA Maintenance Foreman / COR an itemized list of all parts and materials used in the performance of this service. List will be signed and dated by the generator service technician which performed the work. Training requirements: Each contractor on site will need to review, complete, and sign the attached TMS 20939 and return signed document to the COR. Review the attached 6500.6 Appendix C Security NARA PRIVACY-HIPAA CLAUSE attachments: Notice to contractors. Description of Equipment: Bldg. 10 Emergency Generator Manufacturer: Generac / 208V Generator Model: 98A03219-S/ Serial Number: 2042251 Engine Model: 92460 / Serial Number: G3407-2 b. Bldg. 12 Emergency Generator Manufacturer: Generac / 208V Generator Model: 433RSL4021/ Serial Number: LM-239579-0701 Engine Model: OA8829/ Serial Number: 8DC9-446 Bldg. 18 Emergency Generator Manufacturer: Onan Generator Model: 230DFAB / Serial Number: A980673745 Engine Model: LTA10-G1 / Serial Number: 120 Bld. 66 Emergency Generator Manufacture: Cummins Generator Model 125 DSGAB Engine Model: QSB7-G5 NR3 3 The method of Contractor Selection has not been Determined at this time.

Conceptual

Medical

$200,000.00

Public - Federal

Renovation

Our team is requesting plans for this project.

Subscribe For Documents

2 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
9
Active Projects
5
Bidding Soon
63
All Active Projects
24
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

November 3, 2023

img_map_placeholder

113 Comanche Rd, Fort Meade, SD


Get the most reliable construction project data instantly.

Access Now

Get the right
data with Project Intelligence

Share with your network.

Project Shared

with

example@example.com

Upgrade now for industry‑leading commercial construction data.

You've reached the free-view limit.

Thousands of projects are added every week - don't miss out. Explore the best product options for your business and subscribe today.

Get Access Now

Choose what you would like to do.

Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.