BLOCK PAGE!!!

Subscribe For Access

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Saving Project...

Renovation of a military facility in Cannon AFB, New Mexico. Conceptual plans call for the renovation of a military facility.

CZQZ220034 NAICS: 236220 - Commercial and Institutional Building Construction PSC: Z2AA Repair or Alteration of Office Buildings S/B Size Standard: $45M 1. The 27 Special Operations Contracting Squadron (27 SOCONS) is seeking information concerning the availability of capable contractors to provide non-personal services as follows: 2. Description of Services: Estimated Magnitude of Construction: Between $250,000 and $500,000 The Period of Performance completion is estimated at 120 calendar days after Notice to Proceed. The scope of work includes but is not limited to the repair and renovation of building 4620. The following is an outline of the major requirements and are intended to show construction trade disciplines expected to be executed: Demolition: Demolish existing wall partition at Room 120 as illustrated in concept design drawings. Demolish approximately 48 square feet(s.f.) of water damaged gypsum wallboard at entry foyer (Room 100). Demolish cubby shelves in Corridor 130, repair and paint wall to match adjacent. Demolish portion of wall at Room 203 to install new door. Demolish existing "storefront" wall Demolish existing door and frame at Rooms 204, 212. Demolish existing eyewash station at Room 135. Demolish portion of wing wall above countertop, patch, and repair to match existing adjacent walls. (Room 102) Demolish existing sink (Room 102). Demolish existing sink faucet fixture. (Room 102) Demolish existing hi lo drinking fountains in main upper and lower corridors. Demolish / remove 200 s.f. carpet at Op's Reception desk. (Room 110) Demolish / remove 300 s.f. carpet in locker Room. (Room 131) Demolish damaged countertops and install new laminate countertops (Rooms 100A, 100B, 110, 114, 117) New Construction: Provide new General Services Administration (GSA) / CAFB approved Class 5A vault door at existing Armory (Room 112) to match original opening size. (Hamilton or comparable) Install new control entry locks at four (4) ground level locations. Locks to conform to Hardware Specifications. Coordinate combination settings with the facilities users. (6th SOS) Replace approximately 48 s.f. of water damaged gypsum wallboard at entry foyer (Room. 100). Also, check for and mitigate any materials which may potentially have mold. Replace approximately 48 s.f. of water damaged gypsum wallboard at entry foyer (Room. 100). Also, check for and mitigate any materials which may potentially have mold. Replace damaged 2' x 2' ceiling tiles to match existing in kind throughout the building. (approx. 40 panels) Install new eyewash fixture in Room 135. (Bradley or Comparable) Install new solid core wood door at Room 203 (to match existing adjacent room doors) Infill frame and gypsum. board where doors are removed (Room's 204, 212). Install new 8" deep, stainless steel, double bowl model sink. (Room. 102) (Elkay or comparable) Install new stainless steel faucet fixture with spray feature. (Room. 102) (Elkay or comparable) Install new under counter dishwasher adjacent to sink. (Room. 102) Install new single fixture water fountain with bottle fill feature. (Elkay EZ H2O or comparable at upper and lower floor levels) Install new plastic laminate countertops on existing base cabinets or supports Patch, and paint holes in walls to match existing adjacent walls throughout entire building. Install new reverse osmosis water filter system at mechanical room wall where main water line enters building (Room 137) Install new room signage to match existing adjacent room signs. (Room's 123, 124, 203) Install new smoke detectors in new Rooms 123, 124, 203. Install 200 s.f. new carpet to replace existing in kind at Operations reception desk area. (Room 110) Replace missing 5" diameter floor access grommet to match adjacent existing. (Room 120) Install 300 s.f. ceramic floor tile in locker room to match existing adjacent building tile. Provide 4 new 8" diameter air diffusers in existing ductwork above ceiling panels at vestibule (Room 100 / fire sprinkler line and head freeze protection) Adjust ductwork and diffusers above dropped ceilings horizontally side to side as required to accommodate new room partitions. (Rooms 120, 123, 124, 201, 203, 204) Provide new mineral wool insulation wrap at main fire suppression lines above dropped ceiling in entry vestibule (Room 100, freeze protection per NFPA 13 8.16.4.1.6) Adjust any fire suppression system lines / sprinkler drops above ceilings as required to accommodate new room partitions. (Rooms 120, 123, 124, 201, 203, 204) Provide new 120 V / 20 A electrical duplex outlets. (room's 120, 123, 124, 201, 203, 204) Provide new occupant sensor light switches to match existing adjacent rooms tied into the (Energy Saving Performance Contract, ie. ESPC) control system (room's 123, 124, 203) NOTE: Building alarm system shall be retained and in working order. Ensure system is not disturbed or removed during construction activities. New Construction: Provide new General Services Administration (GSA) / CAFB approved Class 5A vault door at existing Armory (Room 112) to match original opening size. (Hamilton or comparable) Install new control entry locks at four (4) ground level locations shown on the provided concept design plans. Locks to conform to Hardware Specifications. Coordinate combination settings with the facilities users. (6th SOS) Replace approximately 48 s.f. of water damaged gypsum wallboard at entry foyer (Room. 100). Also, check for and mitigate any materials which may potentially have mold. Replace approximately 48 s.f. of water damaged gypsum wallboard at entry foyer (Room. 100). Also, check for and mitigate any materials which may potentially have mold. Replace damaged 2' x 2' ceiling tiles to match existing in kind throughout the building. (approx. 40 panels) Install new eyewash fixture in Room 135. (Bradley or Comparable) Install new solid core wood door at Room 203 (to match existing adjacent room doors) Infill frame and gypsum. board where doors are removed (Room's 204, 212). Install new 8" deep, stainless steel, double bowl model sink. (Room. 102) (Elkay or comparable) Install new stainless steel faucet fixture with spray feature. (Room. 102) (Elkay or comparable) Install new under counter dishwasher adjacent to sink. (Room. 102) Install new single fixture water fountain with bottle fill feature. (Elkay EZ H2O or comparable at upper and lower floor levels) Install new plastic laminate countertops on existing base cabinets or supports per CAFB Architectural Compatibility Guide (Room's 100A, 100B, 110, 114, 117) Patch, and paint holes in walls to match existing adjacent walls throughout entire building. Install new reverse osmosis water filter system at mechanical room wall where main water line enters building (Room 137) Install new room signage to match existing adjacent room signs. (Room's 123, 124, 203) Install new smoke detectors in new Rooms 123, 124, 203. Install 200 s.f. new carpet to replace existing in kind at Operations reception desk area. (Room 110) Replace missing 5" diameter floor access grommet to match adjacent existing. (Room 120) Install 300 s.f. ceramic floor tile in locker room to match existing adjacent building tile. (Room 131) Provide 4 new 8" diameter air diffusers in existing ductwork above ceiling panels at vestibule (Room 100 / fire sprinkler line and head freeze protection) Adjust ductwork and diffusers above dropped ceilings horizontally side to side as required to accommodate new room partitions. (Rooms 120, 123, 124, 201, 203, 204) Provide new mineral wool insulation wrap at main fire suppression lines above dropped ceiling in entry vestibule (Room 100, freeze protection per NFPA 13 8.16.4.1.6) Adjust any fire suppression system lines / sprinkler drops above ceilings as required to accommodate new room partitions. (Rooms 120, 123, 124, 201, 203, 204) Provide new 120 V / 20 A electrical duplex outlets where shown on concept design drawings. (room's 120, 123, 124, 201, 203, 204) Provide new occupant sensor light switches to match existing adjacent rooms tied into the (Energy Saving Performance Contract, ie. ESPC) control system where shown on attached concept design (room's 123, 124, 203) NOTE: Building alarm system shall be retained and in working order. Ensure system is not disturbed or removed during construction activities. 3. This Request for Information (RFI) is issued for informational and planning purposes only. This is not a Request for Proposal (RFP). It is not to be construed as a commitment by the Government to issue a solicitation or ultimately award a contract. All attachments to this notice are draft and provided for informational purposes only. Responses will not be considered as proposals, nor will any award be made as a result of this RFI. The Air Force will NOT be responsible for any costs incurred by interested parties in responding to this RFI. Contact with Government personnel other than those specified in this RFI by potential offerors or their employees' regarding this project is prohibited. 4. The Capability Statement should include general information, past performance and technical background describing your firm's experience in contracts requiring similar efforts to meet the program objectives. Interested parties shall not submit more than 10 single-sided, type-written pages using 12-point font or larger. Published literature may be any number of pages. At a minimum the following information is requested: a. Company Cage Code, name, address, point of contact, telephone number and e-mail address. b. Bonding capability. c. Any small business status (8(a), HUB Zone, Disable and/or veteran-owned, women-owned, etc). d. Indicate your role as "Prime Contractor" and what functions for which you plan to self-perform as a percentage of the total and those which you intend to use subcontractors. e. Indicate if your company primarily does business in the government and/or commercial sector. f. Indicate which NAICS code(s) your company usually performs under for government contracts. 5. For your business to be considered as a potential vendor for set aside purposes you must submit a Capabilities Statement as requested by this notice. Failure to do so may result in your business category not being considered as part of a decision by the government to set aside. The information requested by this RFI will be used to facilitate decision making and will not be disclosed outside the agency. 6. If your firm is capable of providing the requirements described above, please provide a Capability Statement to the contract administrator and contracting officer by the deadline indicated in this sources sought. IMPORTANT NOTICE: Following this market research, a pre solicitation notice will be posted for 15 days giving industry formal notification a requirement will be coming with estimated dates. Following that, the solicitation will be posted indicating when bids or proposals will be required. IAW DFARS 252.204-7012, Safeguarding Covered Defense Information and Cyber Incident Reporting. Contractors are required to implement NIST SP 800-171. At time of award, the awardee must be registered in the Supplier Performance Risk System (SPRS) with a minimum of a Basic NIST SP 800-171 DoD Assessment that is not more than 3 years old. The Method of Contractor Selection has not been determined at this Time. *The value for this project is based on a financial range. The value is listed as the highest possible cost from the range provided by a stakeholder or official project document.

Conceptual

Military

$500,000.00

Public - Federal

Renovation

Our team is requesting plans for this project.

Subscribe For Documents

3 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
7
Active Projects
6
Bidding Soon
48
All Active Projects
22
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

May 20, 2024

img_map_placeholder

To Be Determined, Cannon AFB, NM

Get the most reliable construction project data instantly.

Access Now

Get the right
data with Project Intelligence

Share with your network.

Project Shared

with

example@example.com

Upgrade now for industry‑leading commercial construction data.

You've reached the free-view limit.

Thousands of projects are added every week - don't miss out. Explore the best product options for your business and subscribe today.

Get Access Now

Choose what you would like to do.

Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.