Renovation of a municipal facility in Caro, Michigan. Completed plans call for the renovation of a municipal facility.

The following specifications shall be considered in your bid: Quantity (1) Liebert PDX Air-Cooled System Model Number: PX029UA1CD09FC Each unit will provide a total cooling capacity of 101.0 MBH, and a sensible cooling capacity of 89.2 MBH at approximately 75F DB, 61F WB, and 45% RH. 208 Voltage, 3 Phase, 60 Hz, 73.9 FLA, 90.1 WSA, 100 OPD System Details: Upflow with Rear Air Return Liebert iCOM Control with High Definition Display iCOM based communication BACnet IP (Ethernet Port) Modbus RTU (RS-485 Port) IP Protocols over one network Variable speed EC plug fans Digital scroll, variable capacity compressor utilizing R-410A Crankcase Heater Thermal Expansion Valve Evaporator Type: tilted- slab, copper tubes - aluminum fins with hydrophilic coating Two-Stage 12kW Electric Reheat. Infrared Humidifier 7.7 lbs/hr 65,000 Amp, rms Short Circuit Current Rating Locking Disconnect Switch Dual-float condensate pump factory-mounted internal to unit Filter Rating: MERV 8 per ASHRAE 52.2-2007 Unit Color: RAL 7021 Black Gray Matte Supply Air Sensor Temperature/Humidity Sensors internal for return air sensing One Remote Shut Down Contact Three Alarm Contacts 24" Floorstand Full Duct Collar Plenum Plenum Color: RAL 7021 Black Gray Matte One (1) Liebert MC Air-Cooled Microchannel Condenser Liebert MC Condenser Details: Model MCM040E1YD0WFB 208/230 Volt, 3 Phase, 60 Hz, 2.3 FLA, 2.9 WSA, 15 OPD Microchannel aluminum coil Variable Speed EC Fans Premium electronic control board providing communication with iCOM using CANbus Aluminum exterior panels and 18" aluminum legs Single refrigerant circuit condenser R-410A set points Domestic packaging Short Circuit Current Rating of 65,000 Amps, rms Contractor will remove the existing units and provide and install new units, including but not limited to, any required wiring, roof work or repair, curbs, duct, piping, and controls for a complete and operational system. Contractor is responsible to provide and install any special mounting hardware for equipment as well as all installation materials (conduit, tubing, railways, junction boxes, fittings, piping, duct, etc.) for a complete project. All field devices and equipment will be mounted as per manufacturer recommendation. Contractor is responsible for equipment startup Contractor is responsible for on-site installation supervision throughout the duration of the project. Contractor is responsible for patching all building penetrations performed by the contractor during installation. Each unit removal and replacement will occur within the same day. If not possible then temp cooling shall be provided for the equipment room and dispatching area. Contractor shall provide O & M manuals for all contractor provided equipment. This contractor is responsible for all generated trash. Contractor shall clean all work areas on a daily basis and equipment after project completion. Contractor is responsible for all required permits. Installation done as required by Federal, State, local codes and laws and following manufactures recommendations. Any and all correspondence concerning this project shall be directed to Mike Miller Any questions or to set up an appointment please call Mike Miller at 989-672-3756. Tuscola County reserves the right at its sole discretion to reject any and all proposals received without penalty and not to enter a contract as a result of this RFP. The County also reserves the right to negotiate separately with any source whatsoever in any manner necessary to attend to the best interests of the County, to waive irregularities in any proposal and to accept a proposal which best meets the needs of the County, irrespective of the bid price

Award

Municipal

$99,300.00

Public - County

Renovation

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

3

Subscribe For Documents

7 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
97
Active Projects
47
Bidding Soon
853
All Active Projects
347
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

June 30, 2023

August 1, 2023

img_map_placeholder

1301 Cleaver Rd, Caro, MI

The data you need to build the relationships you want. Try it free.

Access Now

Get the right
data with Project Intelligence

Share with your network.

Project Shared

with

example@example.com

Upgrade now for industry‑leading commercial construction data.

You've reached the free-view limit.

Thousands of projects are added every week - don't miss out. Explore the best product options for your business and subscribe today.

Get Access Now

Choose what you would like to do.

Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.