BLOCK PAGE!!!

Subscribe For Access

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Saving Project...

Renovation of a military facility in Richmond, Virginia. Completed plans call for the renovation of a military facility.

Questions & Answers: (updated) 1. Please confirm that the only metering requirement is to re-install or replace the meters currently in place and that any reference to Cyber Security would be moot because no usage or control information will be transferred electronically. RFI 1 - Yes, only metering requirement for B54 boiler replacement is to re-install/replace current meters in place and the usage/control information will not be transferred electronically. 2. During the site visit, potential contractors agreed that the requirement for replacing the concrete foundations was not necessary. We believe the new equipment will fit on the existing foundation pads. (If not, we will modify the pads with full structural strength to accept the equipment) Additionally, the task of replacing the pads can not be performed until after the existing boilers are removed, therefore lengthening the duration the facility will be without boilers/heat. Since boilers may have a very long lead time, this could be problematic and expensive if installation is not completed by heating season. RFI 2- Concrete Pads in B54 boiler room do not need to be replaced in their entirety, based on the condition of the material present. No large cracks, broken pieces or exposed rebar is present requiring the replacement of the entire pad. The requirement for the replacement of the entire pad for each boiler is not needed. 3. Please confirm that only piping larger than 2.0" inches in diameter and within the boiler room must be replaced. RFI 3 - The requirement for piping replacement shall be limited to the lines within the boiler/mechanical room in Building 54 and not the entirety of the system throughout the building. Hot Water, Supply/Return Piping, piping to the Expansion Tank, pumps, valves, etc. shall be replaced, up to the point at which the penetration through the interior building wall occurs. Any piping outside of the mechanical room and boiler room space shall not be replaced. This piping consists of the 2" Dia and larger piping within the mechanical room. 4. Please see drawings provided by the PM. Unfortunately, we do not have a typical DWG file of the boiler room. These alternate drawings are what is available. --- UPDATE: Site visit scheduled 8 August 2023 at 0930. Coordinate site access with Steven Hall at 804-573-2988 or Steven.Hall@dla.mil. Solicitation Defense Supply Center Richmond (DSCR) Building 54 Replacement Boilers This is a solicitation for construction prepared in accordance with the format in FAR Part 36, as supplemented with additional information included in this notice. The solicitation number SP4703-23-R-0008 is issued as a request for proposal (RFP). The resulting contract will be a firm-fixed price award with an expected Period of Performance of 365 days from contract award. This acquisition is set-aside for 100% small businesses. The North American Industry Classification System (NAICS) Code is 238220 (Plumbing, Heating, and Air-Conditioning Contractors). The small business size standard is $19M. Department of Labor Wage Determination based on location of the service provided (Chesterfield County, VA). Partial proposals will not be accepted. For an offer to be considered for award, the contractor must be within a commutable driving distance to the DSCR facility. A 120-mile radius from DSCR is considered the commutable radius. Award will be made to the lowest priced, technically acceptable (LPTA) offeror that meets the requirements stated in the Statement of Work and the solicitation. Also refer to clauses and provisions includes in this notice. Past performance will be considered a part of Technical Acceptability, and the Contracting Officer will pull contractor data from CPARS and SPRS. The contractor must be registered in the System for Award Management (SAM) prior to award. If not already registered in SAM, go to the SAM website www.sam.gov to register prior to submitting your quote. All inquiries must be submitted no later than 7 business days prior to closing date. Acceptable method of quote or inquiries submission is Email to brandon.jump@dla.mil. Site visit TBD. Coordinate site access with Steven Hall at 804-573-2988 or Steven.Hall@dla.mil. Questions are due on August 18, 2023, end of day. Submit questions via email to Brandon.Jump@dla.mil. Quotes are due on August 25, 2023, end of day. Site visit is TBD and will be published on SAM.gov under this solicitation listing. Access to Defense Supply Center Richmond is dictated by the language at the following location: https://www.dla.mil/Aviation/Installation/Visitors-and-ID-Office/ The points of contact (POC) for this requirement are Brandon Jump (brandon.jump@dla.mil). Reference Attachment 1 - Statement of Work (SOW) for additional work scope and details. A new system will be implemented on 3 January 2023 to screen visitors and contractors for installation access at DSCR. The new system is designed to increase efficiencies, enhance the protection of personal information during the vetting process and eliminate the use of hard copy DLA Form 1815s. The new screening system will require visitors and contractors to pre-enroll in DBIDS (Defense Biometric Identification System). To begin the process, visitors and contractors will complete registration through the pre-enrollment website: https://dbids-global-enroll.dmdc.mil. Upon entry of their information, visiting personnel will be provided an electronic form to download, which will have an individualized barcode and alpha numeric code. The codes will be electronically sent to the visiting person's sponsor. Once in receipt of the barcode, the sponsor will email Security and Emergency Services and provide the barcode and sponsorship information. Once the visitor/contractor is vetted and approved for installation access, Security & Emergency Services will notify the sponsor that the visitor/contractor can go to the DSCR Visitor Center to obtain his/her pass. At the Visitor Center, the visitor provides the barcode and code provided earlier in the process and completes the credentialing process.

Post-Bid

Military

$500,000.00

Public - Federal

Renovation

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

5

Subscribe For Documents

4 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
91
Active Projects
46
Bidding Soon
795
All Active Projects
317
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

August 25, 2023

September 25, 2023

img_map_placeholder

8000 Jefferson Davis Hwy, Richmond, VA

Related To This Project


Get the most reliable construction project data instantly.

Access Now

Get the right
data with Project Intelligence

Share with your network.

Project Shared

with

example@example.com

Upgrade now for industry‑leading commercial construction data.

You've reached the free-view limit.

Thousands of projects are added every week - don't miss out. Explore the best product options for your business and subscribe today.

Get Access Now

Choose what you would like to do.

Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.