Privately Funded
Bidding Soon
Documents Available
Publicly Funded
Addenda Available
Post-Bid
Saving Project...
Renovation of a military facility in Columbia, South Carolina. Design plans call for the renovation of a military facility.
As of September 30, 2024, architect has been identified. THIS IS NOT A REQUEST FOR PROPOSAL. THIS IS A REQUEST FOR STANDARD FORM (SF) 330 ARCHITECT-ENGINEER QUALIFICATIONS PACKAGES ONLY. ALL INFORMATION NEEDED TO SUBMIT SF 330 DOCUMENTS IS CONTAINED HEREIN. NO SOLICITATION PACKAGE, TECHNICAL INFORMATION, OR BIDDER/PLAN HOLDER LIST WILL BE ISSUED. THE GOVERNMENT WILL NOT PAY, NOR REIMBURSE, ANY COSTS ASSOCIATED WITH RESPONDING TO THIS REQUEST. THE GOVERNMENT IS UNDER NO OBLIGATION TO AWARD A CONTRACT AS A RESULT OF THIS ANNOUNCEMENT. 1. GENERAL INFORMATION Veterans Health Administration (VHA) Program Contracting Activity Central (PCAC) is seeking sources and intends to award a firm fixed price design contract for Architect-Engineering (A-E) services for the development of complete construction documents, which include working drawings, specifications, and reports, and construction period services for Project #544-355 Construct Behavioral Health Center of Excellence in Columbia, SC. The A-E Services contract that is anticipated to be awarded will be procured in accordance with the Selection of Architects and Engineers statute [formerly known as the Brooks Architect Engineer Act], Federal Acquisition Regulation (FAR) subpart 36.6 Architectural and Engineering Services, VA Acquisition Regulation (VAAR) 836.6, and VA Acquisition Manual (VAAM) M836.6 Architect-Engineer Services. In accordance with FAR 36.209, Construction Contracts with Architect-Engineer Firms, no contract for the construction of a project shall be awarded to the firm that designed the project or its subsidiaries or affiliates, except with the approval of the head of the agency or authorized representative. 2. PROJECT INFORMATION This project is a 100% set-aside for Service-Disabled Veteran-Owned Small Business (SDVOSB) concerns. The NAICS code for this procurement is 541330 Engineering Services and the annual small business size standard is $25.5M. A full design team is required to complete this project. The VA expects to award the anticipated A-E contract in late January 2024. The anticipated period of performance for completion of design is 305 calendar days after notice of award (NOA). The VAAR magnitude of construction is between $10,000,000 and $20,000,000. Please note that the 305-calendar-day period of performance for the design completion begins with the issuance of the NOA and that a notice to proceed (NTP) will not be issued for the completion of a design project. 3. A-E SELECTION PROCESS Firms submitting SF 330s in response to this announcement, not later than the closing date and time specified herein and in accordance with submission requirements, will be considered for evaluation. The selection will be made as follows: SF 330s will be evaluated in accordance with the primary selection criteria as stated in this pre-solicitation notice. These evaluations will determine the most highly qualified firms for this particular requirement. In accordance with FAR 36.602-3(c), at least three of the most highly qualified firms will then be notified of the Government s intent to hold discussions. All firms not invited to participate in discussions will be notified at this time. In accordance with FAR 36.607(b), any requested debriefings of successful and unsuccessful firms will be held after final selection has taken place and will be conducted, to the extent practicable, in accordance with 15.503, 15.506(b) through (f), and 15.507(c). Note that 15.506(d)(2) through (d)(5) do not apply to architect-engineer contracts. Discussions will be held with the most highly qualified firms in the form of written responses or interview presentations. The firms invited to participate in discussions will be notified by email and provided further instructions, including any questions or topics to address. Following the completion of discussions, the firms will be evaluated and ranked based on the primary and (if necessary) secondary selection criteria. The final evaluation and ranking will consider the SF 330 submission for each firm, as well as additional information obtained via discussions. The highest rated firm will be selected to receive the solicitation and engage in negotiations. The solicitation will be issued to the highest rated firm as a Request for Fee Proposal (RFP). All SOW attachments and site-specific documentation will be provided to the highest rated firm with the RFP. A site visit will be authorized during the negotiation process. An award will then be made as long as the negotiation of rates and hours leads to a fair and reasonable determination of the final contract price. If negotiations with the highest rated firm are unsuccessful, the firm will be notified that negotiations have been terminated. Negotiations will then be initiated with the next highest rated firm, and so on until award can be made. 4. SELECTION CRITERIA: Firms responding to this notice will be evaluated and ranked using the primary and secondary selection criteria listed below. The factors are listed in descending order of importance. The evaluation will consider how each factor is addressed and how it is formatted to coincide with the selection criteria. Primary Selection Criteria (listed in descending order of importance): Professional Qualifications (Sections C through E) necessary for satisfactory performance of required service. The AE shall demonstrate they are able to sign and stamp each drawing by individuals licensed in any state in the United States for the key positions listed below. Provide Professional License numbers and/or proof of Licensure. The evaluation shall consider the specific experience (minimum of five years) and qualifications (i.e., education, training, registration, certifications, overall relevant experience, and longevity with the firm as full-time employees) of personnel proposed for assignment to the project, and their record of working together as a team when evaluating professional qualifications. The lead designer in each discipline must be registered but does not have to be registered in the state where the project is located. A resume for each of these key positions MUST be provided identifying their specific role, via Section E in the SF330. Key positions and disciplines required for this project include but are not limited to: Architect (LEED certification/US Green Build Council certification) CAD Technician Estimator/Construction Cost Estimator Registered Communications Distribution Designer (RCDD) Civil Engineer Electrical Engineer Environmental Engineer Fire Protection Engineer Industrial Hygienist Mechanical Engineer Project Manager Quality Assurance/Quality Control Structural Engineer Physical Security Specialist Commissioning Agent. Offer must include the following statement of SDVOSB compliance when submitting the personnel proposed to perform the work under this requirement: I [signatory authority] ___________________, [company] __________________, certify that the SDVOSB prime contractor will not pay more than 50% of the amount paid by the government to the prime for contract performance to firms that are not certified SDVOSBs by the Small Business Association s Veteran Small Business Certification (VetCert) in compliance of VA Acquisition Regulation (VAAR) 852.219-75. The information provided in sections C through E of SF330 will be used to evaluate this evaluation factor. Do not include this information in section H, unless it is pertinent to support the information listed in the other sections. Specialized Experience (sections F, G and H): Specialized experience and technical competence in the design and construction period services in healthcare facilities shall be provided for building additions, renovations, or upgrades of clinical space. Projects experience should include medical center additions and renovations, design of Behavioral Health Facilities and related infrastructure including but not limited to: OIT (IT rooms, Data Centers/Server Rooms configuration, fiber optics, data cable, structured cabling), Electrical Distribution (uninterruptable power systems, electrical bonding, building management systems/building automation systems installation and connection) Mechanical systems (HVAC, Plumbing, Steam systems, Chilled Water systems), Site Preparation (Clearing, grading, utility connections, duct bank, direct boring) Physical Security (access control, door hardware, code compliant ingress and egress). Other specialized experience to provide, should include experience in critical path scheduling, fire protection, construction infection control protocols, energy conservation, pollution prevention, waste reduction, and sustainable design practices. Submissions shall include no more and no less than five (5) recent and relevant Government and private experience projects similar in size, scope and complexity, and experience with the type of projects/competence above. Relevant is defined as those task requirements identified in the Statement of Work. Recent is defined as services provided within the past five (5) years. Each project submitted shall include the following: Project title, location and detailed narrative describing the scope of services provided including the type of work performed by the offeror and its role in the project i.e., prime contractor, Teaming Partner, or subcontractor. Project Owner, owner s point of contact including telephone number and email address. Services & Deliverables provided under the contract/task order. Period of Performance, including start and completion dates Total dollar value of the project: AE Cost Estimate vs. Actual Construction Cost Contract number associated with the project. Section G will be used to evaluate the prior experience of the prime firm and any key subcontractors working together on the provided relevant projects. The offeror shall include narratives addressing the following topics in Section H. Simply re-stating this list in Section H will not be sufficient. The narrative of how well the firm addresses each of these will be evaluated. The management approach. The coordination of disciplines and subcontractors Quality control procedures, and Familiarity with VA Design Guides/Manuals, Master Specifications, and other applicable standards. Capacity (section H): The evaluation will consider the firm s ability to meet the schedule of the overall project, as well as the available capacity of key disciplines to perform the work in the required time. Provide the available capacity of key disciplines by providing current project workload, inclusive of all projects awarded by the VA, any Federal Agency, and Private Sector during the previous twelve (12) months and the full potential value of projects forecasted within the next twenty-four (24) months that the firm has. Include the full potential value of any current indefinite delivery contracts. Offeror shall clearly state their available capacity presenting workload percentages for the key disciplines and/or team members, including sub-consultants. Also, the offeror must provide the completion percentages and expected completion date for all projects current and forecasted. Please ensure the capacity applies toward the team/personnel provided in the SF330. The information for this factor shall be provided in Section H of the SF330. Past performance (section H): Past performance will be evaluated on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules. Past performance will be evaluated for all projects provided in Section F. The Contractor Performance Assessment Rating System (CPARS) database will be reviewed to evaluate the projects that have a VA CPARS entry. VA CPARS projects are not required to be submitted with the SF330 submission. The contract number for the project must be submitted for each project provided in Section F so CPARS can be reviewed in the database. Please note we are unable to review any CPARS from other Federal Agencies, outside of the VA. For any project that does NOT have VA CPARS data available, a Past Performance Questionnaire (PPQ) is required to be submitted with the SF330. If the firm (Prime or Subcontractor) was not the Prime Contractor on any project submitted in the SF330 a PPQ must be provided listing their specific role as a subcontractor. The PPQ should be rated and signed by the evaluator. In the event that a firm does not receive a requested complete PPQ from an evaluator prior to the time for submission, the firm shall submit the partially completed PPQ with Section 1 and the Evaluator Information in Section 2 completed. Ensure a POC is listed with the project title/contract number. The VA will make reasonable attempts to contact the POC upon submission for PPQ completion. The Government may consider additional performance related information regarding the firm, to include customer inquiries, Government databases, publicly available sources, and additional projects in CPARS. The Government reserves the right to contact any POC listed on a CPARS report or PPQ. If appropriate, the record of significant claims against the firm because of improper or incomplete architectural and engineering services may be evaluated. Failure to provide requested data, accessible points of contact, or valid phone numbers will result in a firm being considered less qualified. The information for this factor shall be provided in Section H of the SF 330. For PPQs, please utilize the attached PPQ document. Completed PPQs should be incorporated into the SF 330 directly. PPQs should not be submitted to the VHA PCAC directly. Any PPQs will not be counted towards the page limitations for this submission. However, any narratives provided for past performance in Section H will be counted toward the page limit. Experience in construction period services (Section H): Experience in construction period services must be demonstrated via project experience. These may be the same projects identified above in Factor 1; however, the firm shall clearly delineate the types of construction period services performed for each. Project descriptions must include experience with: Solicitation support services, Professional field inspections during the construction period, Review of construction submittals, Support in answering requests for information during the construction period, Support of construction contract changes to include drafting statements of work and cost estimates, Attendance at weekly conference calls, providing minutes of meetings between the AE, VA, and contractors, Pre-final inspection site visits, Generation of punch-list reports, Coordination with commissioning requirements and Production of as-built documentation. In addition, the firm must include experience addressing unforeseen conditions and emergent situations, conducting situation evaluations and make midcourse corrections. Include description on how the firm can be proactive or responsive in these situations. The firm shall provide a detailed description of projects worked that illustrate experience in these ten areas. Projects must be within the last ten (10) years. The information for this factor shall be provided in Section H of the SF330. Knowledge of Locality (Section H). Knowledge of the locality, to include specific knowledge of certain local conditions or project site features, such as geological features, climatic conditions, working with and local construction methods or local laws and regulations. The information for this factor shall be provided in Section H of the SF 330. Note that the intent of this factor is to showcase a firm s understanding of the site and locality, and NOT where the firm is located, how far away the firm/branch office is from the site, and how they would travel to the site. Information related to the firm s location shall instead be provided in Section H under Secondary Selection Criterion Factor 1, Geographic Location. See below. Secondary Selection Criterion*: Geographic location. Location of the firm, as measured by the driving distance (miles) between the Offeror s principal business location and the Columbia VA Medical Center; 6439 Garners Ferry Rd. Columbia, SC. Determination of the mileage will be based on Google Maps (https://www.google.com/maps/dir/). *The secondary selection criterion is used as a tiebreaker, if necessary, in ranking the most highly qualified firms following the completion of discussions. The secondary selection criterion will not be applied when determining a firm s SF 330 submission. 5. SUBMISSION REQUIREMENTS: The below information contains the instructions and format that must be followed for the submission of the SF 330 Statement of Qualifications: Submit ONE (1) SF 330 Statement of Qualifications to Contract Specialist, Kelly Han at kelly.han@va.gov and Contracting Officer, Maria Rodeffer at maria.rodeffer@va.gov. This must include Parts I and II and any applicable attachments. The submission must include the SF 330, Architect-Engineer Qualifications (form is available online at http://www.cfm.va.gov/contract/ae.asp). The SF 330 submission is due by 2:00 PM ET on November 22, 2023. The SF 330 must be submitted in one email and have a file size no larger than 5 MB. No hard copies will be accepted. The subject line of the email must read: SF 330 Submission - 36C77624R0009 - Project #544-355 Columbia Behavioral Health Center of Excellence Design. The SF 330 submission must not exceed a total of 40 pages. This includes title page, table of contents, and any other relevant information. Any pages submitted by an offeror that exceed the limit will not be considered during the evaluation. Each page must be in Arial size 12 font, single spaced. Part II of the SF 330 and any CPARs or PPQs will NOT count toward the page limitation. A PPQ obtained for another SF 330 submission may be submitted for this project. However, if significant portions of the project have been completed since the PPQ was filled out, a new PPQ should be submitted to accurately assess the project. Firms must include the following information in section B of the SF 330 submission: 1) SAM Unique Entity Identifier 2) Tax ID number 3) Cage code 4) Primary point of contact s email address and phone number All questions must be submitted to kelly.han@va.gov and maria.rodeffer@va.gov with the subject line SF 330 Questions - Project #544-355 Columbia Behavioral Health Center of Excellence Design The cutoff for question submission is 2:00 PM ET on November 10, 2023. Questions will be answered through modification to the pre-sol notice posted to Contract Opportunities at SAM.gov. This procurement is a 100% set-aside for SDVOSB concerns. Offers received from other than SDVOSBs will not be considered. Offerors must be certified as SDVOSBs by the U.S. Small Business Administration (SBA) and visible in the Veteran Small Business Certification (VetCert) database (https://veterans.certify.sba.gov/) at the time of SF 330 submission, written response submission/interview presentations, and award. Failure to be certified in the VetCert database at these times will result in the offeror being deemed ineligible for award. All joint ventures must be SBA certified at the time of SF 330 submission, written response submission/interview presentations, and award and must submit agreements that comply with 13 CFR 128.402 prior to contract award. All prime firms must meet the NAICS code requirement specified in this notice. The Contracting Officer will verify the NAICS code in VetCert. Failure to meet the NAICS code requirement may result in the rejection of the SF 330 submission. SF 330 submissions received after the date and time specified will not be considered. Late proposal rules per FAR 15.208 will be followed for late submittals. Firms not providing the required information may not be evaluated. All information must be included in the SF 330 submission package. It is the offeror s responsibility to check the Contract Opportunities website at SAM.gov for any revisions to this announcement prior to submitting their SF 330. The Method of Contractor Selection has not been determined at this Time. *The value for this project is based on a financial range. The value is listed as the highest possible cost from the range provided by a stakeholder or official project document.
Design
Military
$20,000,000.00
Public - Federal
Renovation
We’ve obtained documents for this project and are currently processing them.
Trades Specified
Division 00 - Lorem Ipsum
Find More Local Projects
Within 75 Miles of This Project
One Low Price
- One license and one market
- Details and key contacts on all bidding projects
- Organize your pipeline with a digital bid board
- Automatically match opportunities to your profile
- Saved searches deliver daily project leads to your email inbox
Market Pricing Around
- All Starter Product functionality
- Access to all documents (plans, specifications, and addenda)
- Access to planning projects
- Access to contact information
- Ability to Export
You’ve Reached the Free View Limit
Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.
Come back in [[refresh_days]] to get [[project_count]] more free projects.
November 3, 2025
6439 Garners Ferry Rd, Columbia, SC
Related To This Project
Columbia, SC
Bid Date: Nov 08 2023
Columbia, SC
Bid Date: May 14 2019
Columbia, SC
Bid Date: Dec 08 2023
Columbia, SC
Bid Date: Oct 25 2023
Columbia, SC
Bid Date: Nov 21 2023
Columbia, SC
--
Columbia, SC
Bid Date: Nov 09 2023
Columbia, SC
Bid Date: Nov 08 2023
Columbia, SC
Bid Date: Jan 03 2024
Columbia, SC
Bid Date: Nov 07 2024
Columbia, SC
Bid Date: Nov 16 2023
Columbia, SC
Bid Date: Oct 26 2023
Columbia, SC
Bid Date: Nov 07 2023
Columbia, SC
Bid Date: Nov 02 2023
Columbia, SC
Bid Date: Oct 26 2023
Recently Viewed
--
--
--
--
--
--
--
--
--
--
The data you need to build the relationships you want. Try it free.
Sign up now to get free company and project data. No payment required.
Get the right
data with Project Intelligence
Project Shared
with
example@example.com
Choose what you would like to do.
Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.
What is your business type?
We have a wide variety of products that are purpose built for certain business types.