Privately Funded
Bidding Soon
Documents Available
Publicly Funded
Addenda Available
Post-Bid
Saving Project...
This is a service / maintenance or supply contract in Santa Monica, California. Contact the soliciting agency for additional information.
BID DESCRIPTION PROVIDE ELECTRICAL SERVICES AS REQUIRED BY WATER RESOURCES DIVISION 4.2. Scope of Work Services will include, but are not limited to: Electrical Services for monitoring Checking the Integrity of Wiring/Connections including: Wiring on Various Pump Motors Variable Speed Drives (VFD) Low, Medium, and High Voltage Electrical Panels and Drives Soft Starters Servo and Motion Controls, Programmable Logic Controllers (PLCs) Equipment includes, but not limited to: Robicon VFDs (Models 457C89-01, 457C89-02, 457C89-03) Flyght Pumps (Models CT3356.715-200HP) Allen-Bradley PowerFlex 400 Drive Siemens Low, Medium and High Voltage Motor Control Center Panels, Starters, Soft Starters and Power Cables Preventive Maintenance shall include the following on an annual basis: Clean and vacuum all the MCC enclosures, cabinets and components form dirt, dust, and debris. Inspect physical and mechanical condition including anchorage, alignment, and grounding. Verify contactors and all mechanical operation. Test motor protection devices in accordance with manufacturer's published data. Verify all Motor-Running Protection. Verify appropriate lubrication on all moving current-carrying parts. Perform insulation-resistance tests on each pole, phase-to-phase and phase-to-ground with starter closed and across each open pole for one minute. Perform resistance measurements through bolted connections with a low-resistance ohmmeter. Perform thermographic survey on all sections of MCC. Test all circuit breakers in accordance with following procedures. Inspect and clean each unit and all contacts. Operate circuit breaker to insure smooth operation. Perform a contact-resistance test. Perform an insulation-resistance test at 1000 volts dc from pole-to-pole and from each pole-to-ground with breaker closed and across open contacts of each phase. Verify Instantaneous, short, long and ground fault pickup and delay by secondary current injection technique. Verify ground-fault pickup and time delay by secondary current injection. Verify tightness of accessible bolted electrical connections by calibrated torque-wrench. Perform thermographic survey on an annual basis. Inspect mechanism contacts and arc chutes in unsealed units. Variable Frequency Drives (VFDs) and Related Components Preventive Maintenance shall include the following on annual basis: Clean and vacuum all the VFD enclosures, cabinets and components from dirt, dust, and debris. Download and backup all VFDs parameters, Faults History and Event Log Files from the VFD's and establish database for them on annual basis. Download and backup of set up parameters on all VFD's and saving them on annual basis. Inspect the VFD electrical components (i.e. discharge resistors, buss bars, rectifiers, IGBT, gate driver, logic boards, etc.) for possible damage due to overloading or abnormal operation. Megger and confirm the insulation resistance of the motor phases to ground as well as between phase winding impedance. Complete torque of all electrical power connections and control terminals. Complete inspection of the cooling mechanisms on all VFD's. Replace and renew cooling fans for all VFD's according to manufacturer recommendation. Test and inspect and on as needed basis replace and renew DC Bus electrolytic capacitor for all VFD's according to manufacturer recommended operational life. Run the VFD and pump at full load to check and confirm all 3 phase motor currents and voltages are balanced and normal. Check and confirming all the 3 phase motor currents and voltages are balanced and read normal. Provide hard copies and electronic copies of all electrical maintenance service records upon completion of every service. Thermographic Survey on all Low, Medium and High Voltage Breakers, Starters and MCC Panels The following service shall be provided on every other year basis: Remove all necessary covers prior to thermographic inspection. Perform thermographic survey when load is applied to the system. Equipment to be inspected shall include all current-carrying devices. Inspect distribution systems with imaging equipment capable of detecting a minimum temperature difference of 1 C at 300 C. Equipment shall detect emitted radiation and convert detected radiation to visual signal. Thermographic surveys should be performed during periods of maximum possible loading. Refer to ANSI/NFPA 70B, Section 20.17. Provide comprehensive photographs and thermographs of the deficient areas. Provide recommendations to address deficiencies Response Time Shall be available to respond to City requests for service 24 hours per day, seven days per week. Shall be available to respond to non-emergency requests within 2 business days. Shall respond to emergency request within 4 hours. 4.3. Vendor Requirements Must be Allen-Bradley factory-trained on controls. Must be a DNH Industries Digi-Fire supplier and service representative. Must have training or continuing education on Siemens equipment. Must provide materials that meet OEM standards and are approved by City staff prior to use. Questions must be submitted online in the "Q&A" tab. The City will only accept or respond to questions submitted through the online vendor portal. Questions regarding this bid are due Tuesday, February 6, 2024 no later than 3:00 pm Pacific Time. Question Submission Deadline:February 6, 2024, 3:00pm
Post-Bid
Municipal
Public - City
Service, Maintenance and Supply
Plans and Specifications are not available for this project. If that changes, they will be made available here.
Trades Specified
Division 00 - Lorem Ipsum
Find More Local Projects
Within 75 Miles of This Project
One Low Price
- One license and one market
- Details and key contacts on all bidding projects
- Organize your pipeline with a digital bid board
- Automatically match opportunities to your profile
- Saved searches deliver daily project leads to your email inbox
Market Pricing Around
- All Starter Product functionality
- Access to all documents (plans, specifications, and addenda)
- Access to planning projects
- Access to contact information
- Ability to Export
You’ve Reached the Free View Limit
Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.
Come back in [[refresh_days]] to get [[project_count]] more free projects.
February 26, 2024
March 27, 2024
Multiple Locations, Santa Monica, CA
Related To This Project
Santa Monica, CA
Bid Date: Jan 31 2024
Santa Monica, CA
--
Santa Monica, CA
Bid Date: Mar 14 2024
Santa Monica, CA
Bid Date: Mar 14 2024
Santa Monica, CA
--
Santa Monica, CA
Bid Date: Mar 01 2024
Santa Monica, CA
Bid Date: Feb 16 2024
Santa Monica, CA
--
Santa Monica, CA
Bid Date: Feb 14 2024
Santa Monica, CA
--
Santa Monica, CA
Bid Date: Jan 24 2024
Santa Monica, CA
Bid Date: Feb 09 2024
Santa Monica, CA
--
Santa Monica, CA
--
Recently Viewed
--
--
--
--
--
--
--
--
--
--
The data you need to build the relationships you want. Try it free.
Sign up now to get free company and project data. No payment required.
Get the right
data with Project Intelligence
Project Shared
with
example@example.com
Choose what you would like to do.
Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.
What is your business type?
We have a wide variety of products that are purpose built for certain business types.