Privately Funded
Bidding Soon
Documents Available
Publicly Funded
Addenda Available
Post-Bid
Saving Project...
Renovation of a mixed-use development in Aurora, Colorado. Conceptual plans call for the renovation of a medical facility.
Sources Sought Notice REQUEST FOR INFORMATION / SOURCES SOUGHT SYNOPSIS The Department of Veterans Affairs Network Contracting Office (NCO) 19 is issuing this sources sought notice as a means of conducting market research to identify parties having an interest in, and the resources to support this requirement for Fire Alarm Panel Upgrade at the Rocky Mountain Regional VA Medical Center at 1700 N. Wheeling St, Aurora CO 80045. The result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 561621 Security Systems Services, Small Business Size Standard: $25.0 Million. This is a request for information and sources only, which may or may not lead to a future solicitation! This is not a solicitation. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred. Contractor shall provide all labor, parts, supplies and equipment necessary to perform Fire Alarm Panel Upgrade shall include but are not limited to: OVERVIEW The contractor shall provide the labor and material to replace the existing data center fire alarm panel and replace or retrofit connected devices at VA Rocky Mountain Regional Medical Center (RMRMC) campus located at VA Medical Center, 1700 N Wheeling Street, Aurora, CO 80045. MANDATORY TASKS AND MATERIALS: The contractor shall use all specified material as well as complete all tasks listed below. Furthermore, the contractor shall furnish all materials, tools, and equipment to perform services for this requirement. Materials: Quantity: (1) Honeywell Notifier NFS-320 Intelligent Addressable Fire Alarm Control Panel, or better. Control panel must be compatible with the current fire alarm system. Control panel must be compatible and fully integrate with ONYXWorks NOTIFIER by Honeywell. Control panel must have a battery backup and surge protection. Control panel must have the ability to connect to single-mode optical fiber. Quantity (14) Notifier by Honeywell FSP-951 smoke detectors. Including all required mounting hardware. Quantity (6) Notifier by Honeywell FRM-1 Intelligent Control and Relay Modules. Quantity (5) Notifier by Honeywell FMM-101 Intelligent Monitor Modules. Quantity (2) Notifier by Honeywell FCM-1-REL Releasing Control Module. Quantity (2) Notifier by Honeywell NBG-12LR Releasing Pull Stations. Quantity (2) Direct Fired Impulse Actuator (DFIA) kits. Quantity (4) 10-Amp 24 VDC 110 VAC Relays. Quantity (2) LENS-R2 Red lenses for speaker/strobe, wall mount. Any other components required to complete the project, maintain all existing functionality, and integrate connected devices with ONYXWorks. Scope: Contractor shall replace the Fike Cheetah Xi panel located in room GP-103. Contractor shall replace or retrofit all Fike Cheetah equipment connected to the control panel. Contractor shall connect all wire inside the fire alarm system control panel, at devices, annunciator panels and remote power supplies provided by the contractor. Contractor shall install any required wire, system devices, and raceway to complete the project. Contractor shall test all functionality and provide a commissioning report to the VA. COMPETENCY AND CERTIFICATION OF PERSONNEL SERVICING EQUIPMENT Contractor shall demonstrate relevant years of experience installing and/or performing maintenance including installing master remote modules. Must be able to demonstrate experience with Anixter equipment. Please be advised it is the potential contractor s responsibility to submit any and all licenses and certifications for the employees they plan to utilize for this project with the quote they submit. Moreover, at any time during the period of performance the COR reserves the right to request copies of contractor employee certifications, licenses, etc. BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE, THIS REQUIREMENT MAY BE SET-ASIDE FOR SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION, and multiple awards MAY be made. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. SUBMISSION INSTRUCTIONS: If your organization can provide these services and is interested in this opportunity, please respond to Noaa Lanotte, Contract Specialist, Department of Veterans Affairs, NCO 19, 6162 South Willow Drive, Suite 300, Greenwood Village, Colorado 80111 via e-mail at Noaa.Lanotte@va.gov with a statement describing your capabilities. The capability statement shall include a point of contact, complete mailing address, telephone number, email address, and state the company s business size status and should address this specific requirement, with appropriate documentation supporting claims of organizational and staff capability. Please be as thorough as possible in your submission. Requests for copies of a solicitation will not be honored or acknowledged. The deadline for responses is Wednesday, May 15, 2024, at 10:00 AM Mountain Time. The Method of Contractor Selection has not been determined at this Time.
Conceptual
Medical
$400,000.00
Public - Federal
Renovation
Trades Specified
Division 00 - Lorem Ipsum
Find More Local Projects
Within 75 Miles of This Project
One Low Price
- One license and one market
- Details and key contacts on all bidding projects
- Organize your pipeline with a digital bid board
- Automatically match opportunities to your profile
- Saved searches deliver daily project leads to your email inbox
Market Pricing Around
- All Starter Product functionality
- Access to all documents (plans, specifications, and addenda)
- Access to planning projects
- Access to contact information
- Ability to Export
You’ve Reached the Free View Limit
Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.
Come back in [[refresh_days]] to get [[project_count]] more free projects.
May 15, 2025
1700 N Wheeling St, Aurora, CO
Related To This Project
Aurora, CO
--
Aurora, CO
Bid Date: Jun 13 2024
Aurora, CO
Bid Date: Jun 12 2024
Aurora, CO
Bid Date: Jun 03 2024
Aurora, CO
Bid Date: Jun 20 2024
Aurora, CO
Bid Date: Jul 11 2024
Aurora, CO
Bid Date: Jun 18 2024
Aurora, CO
Bid Date: May 28 2024
Aurora, CO
Bid Date: May 24 2024
Aurora, CO
Bid Date: Jan 11 2021
Aurora, CO
Bid Date: May 23 2024
Aurora, CO
Bid Date: May 23 2024
Aurora, CO
Bid Date: Jun 25 2020
Recently Viewed
--
--
--
--
--
--
--
--
--
--
The data you need to build the relationships you want. Try it free.
Sign up now to get free company and project data. No payment required.
Get the right
data with Project Intelligence
Project Shared
with
example@example.com
Choose what you would like to do.
Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.
What is your business type?
We have a wide variety of products that are purpose built for certain business types.