BLOCK PAGE!!!

Subscribe For Access

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Saving Project...

Renovation of a military facility in Neah Bay, Washington. Completed plans call for the renovation of a military facility.

SCOPE: Contractor shall provide labor, material, and supervision to perform an installation of air conditioning system as described herein. Contractor shall perform all construction work and remove all associated waste IAW local, state, and federal regulations. a) Furnish and install 2 each, 3-ton single zone, cooling only split AC units. Indoor unit shall be wall-mounted, powered from outdoor unit. Refrigerant type shall be R410A. Mfg/model shall be Daikin NV series or approved equal. b) Furnish and install pad and anchors for outdoor units. c) Provide wall openings for refrigerant lines and drain penetrations. Caulk seal watertight. Provide refrigerant lines between indoor and outdoor units. Route condensate drain line from indoor units to the outside, and terminate to daylight at 6 inches above grade. d) Furnish and install circuit breakers (2x 20A, 208V, 1ph - field verify) to replace existing breakers and provide power to new AC units. Disconnect power from existing AC units and tag units "OOC, abandoned in-place". Remove R22 refrigerant from both existing AC units and dispose in accordance with regulatory requirements. e) For space temperature controls, set one indoor unit setpoint to 75 degrees F for normal space temperature control. Set the 2nd indoor unit to 80 degrees F for standby and runs automatically in the event of a load spike in the space. 2. COMMENCEMENT, PROSECUTION, AND COMPLETION OF WORK: Upon acceptance, the contractor shall commence work within 15 days and work diligently to complete the entire project and have the work completed by 60 working days from scheduled assessment after contract award. 3. INFORMATION AND REQUIREMENTS: Physical Characteristics of the site. 1. Refer to site plans. No address on hand. Lat and Long from google maps 4822'14.3"N 12440'22.7"W, Bahokas Peak Rd, Neah Bay, WA 98357 DESCRIPTION: Installation of AC unit at Bahokas Peak Site to cool down sensitve equipment. Exact requirements listed below: Furnish and install 2 each, 3-ton single zone, cooling only split AC units. Indoor unit shall be wall-mounted, powered from outdoor unit. Refrigerant type shall be R410A. Mfg/model shall be Daikin NV series or approved equal. Furnish and install pad and anchors for outdoor units. Provide wall openings for refrigerant lines and drain penetrations. Caulk seal watertight. Provide refrigerant lines between indoor and outdoor units. Route condensate drain line from indoor units to the outside, and terminate to daylight at 6 inches above grade. Furnish and install circuit breakers (2x 20A, 208V, 1ph - field verify) to replace existing breakers and provide power to new AC units. Disconnect power from existing AC units and tag units "OOC, abandoned in-place". Remove R22 refrigerant from both existing AC units and dispose in accordance with regulatory requirements. For space temperature controls, set one indoor unit setpoint to 75 degrees F for normal space temperature control. Set the 2nd indoor unit to 80 degrees F for standby and runs automatically in the event of a load spike in the space. This notice is a combined synopsis/solicitation for a commercial products and commercial services in accordance with Federal Acquisition Regulation Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes a public solicitation. Please read this entire notice, the instructions herein, and the attachment documents carefully. This acquisition is on a Small Business Set-Aside only. HOW TO RESPOND: To compete for this project, interested parties must be registered in SAM (System for Award Management) prior to close of this solicitation. https://www.sam.gov/portal/public/SAM/. The vendors SAM registration must be in an "ACTIVE" status prior to award. Vendors must ensure that the above listed NAICS codes are listed on their SAM registration to perform this type of service. COST PROPOSALS: The contract will be awarded using simplified acquisition procedures in accordance with FAR part 13 and part 15 provide Firm Fixed-Price "broken out by labor hours, labor category, materials, and other direct costs". Offerors must submit the proposal to Elizabeth Meister at elizabeth.a.meisteruscg.mil. EVALUATION CRITERIA: The government will award a contract resulting from this request for quote (RFQ) to the responsible offeror whose offer conforming to the RFQ is the Lowest price Technically Acceptable (LPTA) quote. The lowest priced quote will be evaluated on technical acceptability, if it is found to be acceptable, an award will be made. If it is found to be unacceptable, the next lowest price will be evaluated. This process will continue until a technically acceptable offer is identified. INQUIRIES: Telephone inquiries as described in the Statement of Work. Looking for a contractor to provide all personnel, equipment, transportation, tools, materials, supervision, and other items and services necessary for installation and testing of Air Conditioning unit. See attachments for SOW and additional information.

Post-Bid

Military

$100,000.00

Public - Federal

Renovation

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

3

Subscribe For Documents

4 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
47
Active Projects
16
Bidding Soon
862
All Active Projects
330
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

July 31, 2024

August 30, 2024

img_map_placeholder

Bahokas Peak Rd, Neah Bay, WA

Related To This Project


The best commercial construction data available. Period.

Access Now

Get the right
data with Project Intelligence

Share with your network.

Project Shared

with

example@example.com

Upgrade now for industry‑leading commercial construction data.

You've reached the free-view limit.

Thousands of projects are added every week - don't miss out. Explore the best product options for your business and subscribe today.

Get Access Now

Choose what you would like to do.

Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.