Published June 11, 2025 at 8:00 PM

Updated June 12, 2025

Site work and renovation of a mixed-use development in Las Vegas, Nevada. Completed plans call for the renovation of a educational facility; and water / sewer project.

Elevator Door Lock Monitoring, Overspeed Valve and Shut Off Valve Project For Public Works Projects, a Bidder Must Be Qualified as a Bidder With the State Public Works Division of the Department of Administration for the Cost Category Required for the Project Question Deadline 04/24/2025 at 12:00 AM PT UNLV is seeking an experienced Contractor for its Door Lock Monitoring Project (system to monitor and prevent automatic operation of the elevator with faulty door contact circuits), with work to be completed before the end of 2025. 1. Scope of Work: o Nevada law requires every existing elevator installed before 2000 must comply with the minimum safety requirements as described in ASME A17.3 2020. NAC 455C.500: Provisions 2.7.5 (restricted opening of hoistway doors) and 3.10.12 (system to monitor and prevent automatic operation of the elevator with faulty door contact circuits) of the ASME A17.3 Safety Code for Existing Elevators and Escalators, 2020 Edition will come into effect on December 31, 2025. Per ASME A17.3 2000, this includes Door Lock Monitoring (DLM). Overspeed valves (OSV) and Shutoff valves (SV). ASME A17.3 governs the following; o Every existing elevator installed before 2000 must comply with the minimum safety requirements elaborated in ASME A17.3 2020. Per Bulletin MCS 2301 dated September 22, 2023, and the revised edition of Nevada Administrative Code (NAC) 455C dated August 22, 2023: o UNLV has 47 elevators that require the installation of Door Lock Monitoring (system to monitor and prevent automatic operation of the elevator with faulty door contact circuits) before the end of 2025 to comply with ASME A17.3. DLM spec o Additionally, per ASME A17.3, UNLV has 37 hydraulic elevators that must be equipped with an over speed valve (OSV - ASME A17.3 4.3.3[b]) and 28 elevators that need shut off valves (SV - ASME A17.1 8.7.3.24/3.19). Please see Exhibit C - Pricing Response Form Spreadsheet Attachment for this listing. o Due to the deadline to complete door lock monitoring by December 31, 2025, this scope of work requested is to include DLM, OSV and SV and must be completed by then.

Award

Educational

$659,440.00

Public - State/Provincial

Renovation, Site Work

5

7

8

5

Subscribe For Documents

10 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
13
Active Projects
0
Bidding Soon
278
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

May 8, 2025

June 9, 2025

Project location map

1001 Shadow Ln, Las Vegas, NV

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.