BLOCK PAGE!!!
Get Full Details

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Published November 25, 2025 at 7:00 PM

Updated November 26, 2025

Site work and paving for a residential development in Richmond, Texas. Completed plans call for site work for a one-story above grade residential development.

Construction of the Water, Sanitary Sewer, Drainage Facilities & Paving and Appurtenances to serve The George Section 5, LJA Job No. 4683-6205A&B. Bids must be submitted electronically via the specified website, with bidder registration required to submit or download bidding documents. Each bid must be accompanied by a bid security in the form of a bid bond or cashier's check payable to GF 2977 LP on behalf of Fort Bend County Municipal Utility District No. 237A, in an amount not less than five percent (5%) of the submitted bid. Question Deadline 11/10/2025 All questions about the meaning or intent of the Bidding Documents are to be directed to ENGINEER. As necessary, interpretations or clarifications will be issued by Addenda mailed or delivered to all parties having received the Bidding Documents. Questions received less than three working days prior to the date for opening of Bids may not be answered. Verbal discussions and answers are not binding. Completion-145 calendar days 8" pvc water line, c-900, dr 18, class 235, includes fittings, bedding and backfill, all depths 8" awwa gate valve & box, complete in place fire hydrant unit, includes appropriate tee, fittings, 6" gate valve & box, and lead pipe, all depths, complete in place wet connection of proposed water line to existing water line, includes fittings, all adapters and connectors necessary, and removal of existing plug & clamp and 2" blow-off valve & box, all sizes, all depths, sanitary sewer items - 8" pvc sewer pipe, astm d-3034, sdr 26, 0' - 12' cut, includes bedding and backfill, complete in place 8" pvc sewer pipe, astm d-3034, sdr 26, 12' - 16' cut, includes bedding and backfill, complete in place short side double or single 6" pvc pipe service lead, astm d-3034, sdr 26, includes pipe, cement stabilized sand backfill, riser, wye, plug, marker, and any necessary fittings, all depths, complete in place drainage facilities items - 24" rcp storm sewer, astm c-76, class iii, includes bedding and backfill, all depths, complete in place 30" rcp storm sewer, astm c-76, class iii, includes bedding and backfill, all depths, complete in place 36" rcp storm sewer, astm c-76, class iii, includes bedding and backfill, all depths, complete in place\ 42" rcp storm sewer, astm c-76, class iii, includes bedding and backfill, all depths, complete in place

Bid Results

Residential Subdivision

$1,897,950.00

Public - County

Paving, Site Work

59

14

7

6

Subscribe For Documents

19 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
384
Active Projects
222
Bidding Soon
3,663
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

November 20, 2025

January 12, 2026

Project location map

To be determined, Richmond, TX


Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.