BLOCK PAGE!!!

Subscribe For Access

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Saving Project...

This is a service / maintenance or supply contract in Manchester, New Hampshire. Contact the soliciting agency for additional information.

Combined Synopsis Solicitation Manchester VAMC HVAC Maintenance Service (i) This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. (ii) The solicitation number is 36C24123Q0994 and the solicitation is issued as a request for quotation (RFQ). (iii) A statement that the solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2023-01. (iv) This requirement is being issued as an SDVOSB set-aside. The associated NAICS 238220 and small business size standard is $16.5 million. (v) The Government intends to award a firm-fixed price award for HVAC Maintenance Service at the Manchester New Hampshire VAMC. Please see the attached Performance Work Statement for full requirement details. Please complete the Price Schedule below and submit with the quote submission. (vi) The Contractor shall provide all resources necessary to provide HVAC Maintenance Service IAW the attached (Performance Work Statement). Please see the attached PWS for full requirement details. (vii) The Place of Performance is Manchester New Hampshire as described per the (Performance Work Statement). (viii) Provision at 52.212-1, Instructions to Offerors -- Commercial, applies to this acquisition in addition to the following addenda s to the provision: 52.252-1 Solicitation Provisions Incorporated by Reference (FEB 1998); 52.204-7 System for Award Management (OCT 2018); 52.204-16 Commercial and Government Entity Code Reporting (JUL 2016); 52.217-5 Evaluation of Options (JUL 1990); 852.252-70 Solicitation Provisions or Clauses Incorporated by Reference (JAN 2008) (ix) Provision at 52.212-2, Evaluation -- Commercial Items, applies to this requirement. Site Visit: September 6, 2023. Submission of Quotes: (1) Quotes shall be received on or before the date and time specified in Section (xv) of this solicitation. Note: Offers received after the due date and time shall not be considered. (2) Offerors shall submit their quotes electronically via email to tnauri.woodbridge@va.gov. (3) Questions: Questions shall be submitted to the Contracting Officer in writing via e-mail. Oral questions are not acceptable due to the possibility of misunderstanding or misinterpretation. The cut-off date and time for receipt of questions is September 8, 2023 by 12:00 PM EST. Questions received after this date and time may not be answered. Questions shall be answered in a formal amendment to the solicitation so all interested parties can see the answers. (4) Quote Format: The submission should be clearly indexed and logically assembled in order of the evaluation criteria below. All pages of the quote shall be appropriately numbered and identified by the complete company name, date and solicitation number in the header and/or footer. Evaluation Process: Award shall be made to the best value, as determined to be the most beneficial to the Government. Please read each section below carefully for the submittals and information required as part of the evaluation. Failure to provide the requested information below shall be considered non-compliant and your quote could be removed from the evaluation process. Offeror quotes shall be evaluated under FAR Part 13.106-2(b) -- Evaluation of Quotations or Offers. Therefore, the Government is not obligated to determine a competitive range, conduct discussions with all contractors, solicit final revised quotes, and use other techniques associated with FAR Part 15. The Government shall award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation shall be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate offers:A Price (Follow these instructions): Offeror shall complete Attachment 1 - Price Schedule, with offerors proposed contract line item prices inserted in appropriate spaces.A Past Performance: Offeror shall utilize Attachment 2 Past Performance Worksheet to provide at least one (1) but no more than (3) references of work, similar in scope and size with the requirement detailed in the (Performance Work Statement). References may be checked by the Contracting Officer to ensure your company is capable of performing the Statement of Work.A The Government also reserves the right to obtain information for use in the evaluation of past performance from any and all sources. Technical: The offeror s quote shall be evaluated to determine if the organization has the experience and capabilities to provide the requested services IAW the (Performance Work Statement) in a timely efficient manner.A Contractor shall demonstrate their corporate experience and approach to meet all requirements stated in the (Performance Work Statement). Contractor shall demonstrate that their technicians meet the qualification standards stated in the (Performance Work Statement). If you are planning to sub-contract some or all of this work, please provide the name and address(s) of all subcontractor(s) (if applicable) and a description of their planned subcontracting effort. SAM: Interested parties shall be registered in System for Award Management (SAM) as prescribed in FAR Clause 52.232-33. SAM information can be obtained by accessing the internet at www.sam.gov or by calling 1-866-606-8220. Interested parties not registered in SAM in sufficient time to meet the VA s requirement will be ineligible to receive a government contract. This determination will be at the discretion of the Contracting Officer. VISTA: The VA utilizes VISTA to issue a purchase order and liquidate invoices. Failure to register in VISTA may result in exclusion from the issuance of a VA contract. This determination will be at the discretion of the Contracting Officer. Interested parties with no prior VA contracts can request a Form 10091 at any time. (x) Please include a completed copy of the provision at 52.212-3, Offeror Representations and Certifications -- Commercial Items, with your offer via the SAM.gov website or a written copy. (xi) Clause 52.212-4, Contract Terms and Conditions -- Commercial Items (OCT 2018), applies to this acquisition in addition to the following addenda s to the clause: 52.204-16 Commercial and Government Entity Code Maintenance (JUL 2016); 52.219-6 Notice of Total Small Business Set-Aside; 52.232-40 Providing Accelerated Payments to Small Business Subcontractors (DEC 2013); 852.203-70 Commercial Advertising (MAY 2008); 852.232-72 Electronic Submission of Payment Requests (NOV 2018) Subcontracting Commitments - Monitoring and Compliance This solicitation includes VAAR 852.215-70, Service-Disabled Veteran-Owned and Veteran-Owned Small Business Evaluation Factors, and VAAR 852.215-71, Evaluation Factor Commitments. Accordingly, any contract resulting from this solicitation will include these clauses. The contractor is advised in performing contract administration functions, the CO may use the services of a support contractor(s) to assist in assessing contractor compliance with the subcontracting commitments incorporated into the Information Protection and Non-Disclosure and Disclosure of Conflicts of Interest Agreement to ensure the contractor's business records or other proprietary data reviewed or obtained in the course of assisting the CO in assessing the contractor for compliance are protected to ensure information or data is not improperly disclosed or other impropriety occurs. Furthermore, if VA determines any services the support contractor(s) will perform in assessing compliance are advisory and assistance services as defined in FAR 2.101, Definitions, the support contractor(s) must also enter into an agreement with the contractor to protect proprietary information as required by FAR 9.505-4, Obtaining access to proprietary information, paragraph (b). The contractor is required to cooperate fully and make available any records as may be required to enable the CO to assess the contractor compliance with the subcontracting commitments. (xii) Clause at 52.212-5, Contract Terms and Conditions Required To Implement Statutes Or Executive Orders -- Commercial Items, applies to this acquisition and in addition to the following FAR clauses cited, which are also applicable to the acquisition: 52.204-10, 52.209-6, 52.219-6, 52.219-28, 52.222-3, 52.222-21, 52.222-26, 52.222-36, 52.222-50, 52.223-18, 52.232-33, 52.222-41, 52.222-43 (Wage Determination Applicable (Manchester 2015-4019 Rev 23 posted on beta.sam.gov) (xiii) All contract requirement(s) and/or terms and conditions are stated above. (xiv) The Defense Priorities and Allocations System (DPAS) and assigned rating are not applicable to this requirement. (xv) RFQ responses are due September 13, 2023 by 12:00 PM EST. RFQ responses must be submitted via email to: tnauri.woodbridge@va.gov. Hand deliveries shall not be accepted. (xvi) The POC of this solicitation is Tnauri.Woodbridge@va.gov) ATTACHMENT 1 PRICE SCHEDULE ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 HVAC Maintenance Service 1.00 JB __________________ __________________ 1001 HVAC Maintenance Service 2001 HVAC Maintenance Service 3001 HVAC Maintenance Service 4001 HVAC Maintenance Service GRAND TOTAL __________________ ATTACHMENT 2 PAST PERFORMANCE WORKSHEET 1. Name of Contracting Activity, Government Agency, Commercial Firm or other Organization: 2. Contracting Activity Address: 3. Contract Number: 4. Date of Contract Award: 5. Beginning Date of Contract: 6. Completion Date of Contract: 7. Contract Value: 8. Type of Contract: 9a. Technical Point of Contact: 9b. Contracting Point of Contact: Name: Name: Title: Title: Address: Address: Telephone: Telephone: Email: Email: 10. Place of Performance: 11. Description of Work (Use a continuation sheet if necessary): 12. List any commendations or awards received: 13. List of Major Subcontractors: ATTACHMENT 3 DEPARTMENT OF VETERANS AFFAIRS MEDICAL CENTER MANCHESTER, NH BOILER PLANTS STATEMENT OF WORK Maintenance Service Contract INTRODUCTION The VA Medical Center in Manchester is seeking a qualified contractor to perform comprehensive preventative maintenance and repair services for heating, ventilating and air conditioning (HVAC), compressed air, and medical air/vacuum systems at our campus. Service performance will be for the VAMC- Manchester at 718 Smyth Road, Manchester, NH 03104. BACKGROUND The VA equipment for heating, ventilating, air conditioning, (HVAC), compressed air, and medical air/vacuum is required preventative maintenance (PM) on a periodic basis through the year. The Facility Service, Maintenance Department, acquires assistance in keeping up with required PMs on the equipment to ensure proper operations and prevent failure points on the equipment. Our current Maintenance staff is shorthanded to ensure proper PMs are being completed as well as responding to maintenance calls, performing regular duties, and handling the increase work order requests. A service contract would be needed to ensure the proper and timely of the required PM s on the HVAC equipment/systems. SCOPE Item 1 Preventative Maintenance (PM) The contractor shall provide all personnel, equipment, tools vehicles, materials, supervision, and other items and services necessary to perform preventative maintenance, testing and repair tasks functions for the equipment described in the SOW. Contractor shall perform preventative maintenance (PM) for all equipment listed in Attachment A, including ancillary components associated with the functioning of these devices. PM shall be performed in a manner designed to optimize the reliability, efficiency and lifespan of the equipment serviced. The contractor shall adhere to all individual manufacturer s requirements and instructions for the particulars of scheduled maintenance of the systems/equipment. All contractor personnel and subcontractors that perform scheduled maintenance shall be qualified by the systems/equipment manufacturer where necessary to preserve any warranties on the systems/equipment. The contractor shall provide a written monthly schedule to the Contracting Officer Representatives (COR) for the facility, listing the specific equipment to be serviced during the upcoming period and outlining the individual PM tasks to be completed, including any after-hours service. The contractor shall obtain, provide and install all parts, materials, and supplies necessary to perform PM, and shall be responsible for the cost of same within their base bid amount. Contractor shall use parts supplied by the original equipment manufacturer (OEM) or authorized equal (as stipulated by the manufacturer) when replacing all parts, components, and/or devices for the covered systems. Should the contractor encounter a part in need of replacement, and the direct replacement is no longer available due to obsolescence, the contractor shall replace that part with a new equivalent part. The contractor shall notify the VA when such replacements/modernization occurs. The contractor shall provide labor, material, and equipment necessary to perform start up and routine maintenance services to include but not be limited to the following, at the intervals specified in Attachment A. The vendor shall perform all manufacturer recommended routine maintenance on the following equipment/systems. Scheduled Maintenance of Chillers. Scheduled Maintenance of Air Handlers units. Scheduled Maintenance of Condensers. Scheduled Maintenance of Boilers. Scheduled Maintenance of Circulating and Heating Pumps. Scheduled Maintenance of Air Compressors. Scheduled Maintenance of Fan Coil & Return Fan Units. Scheduled Maintenance of Medical Air/Vacuum System. Scheduled Maintenance of Fume Exhaust Systems. The vendor shall perform all manufacturer recommended routine maintenance, whether or not included in the list below: Change all filters per manufacturer s recommendations. Check all electrical wiring and connections; tighten as required. Check all motor starter contactor surfaces for wear. Lubricate electrical motor and fan bearings, if applicable. Check all belts for wear and tensioning, if applicable. Check all mounting hardware, tighten as needed. Check and calibrate controls. Check condition of evaporator coils; clean at intervals recommended by manufacturer or more frequently as needed. Check and clean condensate drains, drain line and pans. Check refrigerant charge, repair leaks and add charge as needed. Take refrigerant and oil samples and send for manufacturer s recommend analysis of contaminants (annually). Verify all critical flow rates of refrigerant and cooling loops. Furnish and replace oil filter and purge drier (as needed per manufacturer s maintenance schedule). Verify proper operation of controls. Check chilled water setpoint and verify performance. Inspect and verify operation of vane arms. Check refrigerant levels and perform refrigerant leak tests. Check oil levels and change oil as needed. Perform chemical cleaning of condenser coils (annually or as per manufacturer s guidance). Verify operation of oil sump heaters. Verify full capacity of chilled water system. Test operation of all flow proving devices. Verify panel operation, amperage, and voltage. Verify proper operation of all slide and solenoid valves. Check high condenser pressure and low refrigerant temp sensors. Review operating procedures with site personnel. Perform burner test and calibration. Check and service engine coolant heat exchangers. Check solution pump and purge operation. Provide cleaning of Fume Exhaust System for both maintenance, bathroom, and kitchen equipment/systems. Provide testing and certification on Fume exhaust systems and hoods. Provide Medical Gas Testing and Evaluation to meet annual requirements. Perform correction action for the Medical Gas systems on any deficient/non-compliant areas. All other PM tasks as per manufacturer s recommendations. The scope consists of routine preventative maintenance service and needed repairs to the equipment and associated components listed in Attachment A; Equipment Inventory, as well as certain specified testing and balancing services. The Contractor is required to inspect and service all equipment in accordance with all manufacturer's recommendations, prevailing industry standards and codes. Personnel Qualifications- Before assigning employees to start work under the terms of this contract, the Contractor shall ensure that they have the required qualifications and, if applicable, possess the required current and valid professional certifications and licenses in compliance with federal, state, and local environmental requirements and laws. Personnel operating motor vehicles shall have a valid state driver s license and abide by all NH VAMC Healthcare System traffic laws, i.e. hands-free cell phone use while driving, and parking requirements. As part of the quotation, the Contractor shall submit information on the qualifications or certifications for employees and sub-contractors proposed to work on the services of this contract. Journeyman tradespersons shall be licensed for their respective trades in accordance with Federal requirements. Note: All HVAC trades personnel working with refrigerants shall have universal Environmental Protection Agency (EPA) certification. Contractor will ensure all certificates, licenses and permits are kept current and valid. All license and certification renewals shall be submitted to the COR annually or as requested. The COR shall track Contractor compliance with any manufacturers and contract warranties and shall maintain on-site records of equipment bearing warranties. The contractor shall provide fully completed worksheets to the COR with sufficient detail concerning each completed task. The contractor will annotate equipment records showing warranted items and warranty expiration dates on all equipment. The contractor shall provide supporting documentation for any warranty claims to the on-site COR. The Government will provide the contractor with all existing warranty documentation at the start of the task order. The contractor shall maintain and inspect all infrastructure systems under warranty, without voiding the warranty. An equipment inventory is incorporated into this Site-Specific statement of work. The contractor is responsible for all required routine maintenance of the equipment included in the inventory and as described herein, necessary to ensure proper function of the equipment in accordance with manufacturer s guidelines, applicable standards and codes. Any unscheduled maintenance/repair work shall be performed when authorized by the Contracting Officer CO or COR, in accordance with Government-approved technical instructions and facility priorities. NOTE: unscheduled maintenance does not include routine maintenance. Routine maintenance services must be incorporated within the base bid amount. The CO and COR shall notify and work with the contractor on any additional equipment added or changes to the equipment list for PMs and frequency. The contract will then be modified to address the updated costing to the service agreement. Also, the CO and COR shall notify and work with the contractor to remove the equipment item from coverage because it can no longer be economically maintained or has been removed/replaced from the property. The contract will then be modified to address the updated costing to the service agreement. Item 2 HVAC System Testing and Balancing (TAB) The contractor shall perform annual HVAC testing and balancing of the Pharmacy, Same Day Surgery, and Sterile Processing Service at the VAMC- Manchester. The work shall be conducted in accordance with VHA Specification 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC and Chapter 39, "Testing, Adjusting and Balancing" of 2019 ASHRAE Handbook, "HVAC Applications", hereby incorporated by reference. The work shall include, but not be limited to the following: Planning systematic testing and balancing procedures. Design Review Report. Systems Inspection report. Duct Air Leakage test report. Systems Readiness Report Balancing air and water distribution systems; adjustment of total system to provide design performance; and testing performance of equipment and automatic controls. Vibration and sound measurements. Recording and reporting results. Document critical paths of flow on reports. The contractor shall be provided mechanical drawings for the air handing units and areas being tested. Report shall include supply airflow rates, air exchange rates, exhaust airflow rates and room pressure relation to adjacent space. Airflow rates will be measured for each register. Contractor shall perform TAB work during off hours including weekends in specialty areas, such as Operating Rooms, to avoid interfering with the Medical Center s normal operations. In sterile areas, the contractor will be required to wear sterile clothing and follow the facility policy regarding infection control. The contractor shall be provided mechanical drawings for the air handing units and areas being tested. Item 3- Sewer System Flushing and Maintenance The contractor shall provide quarterly flushing, clearing, and cleaning of the site sewer system of the VAMC Medical Center. The sewer system is descripted on the sewer system schematic/drawings. Attach separately is the sewer system schematic. The contractor shall provide the necessary labor, materials, and equipment to perform the quarterly flushing. In addition to the quarterly flushing, the contractor shall provide an Annual Maintenance of all the building sanitary drains to include camera imaging and snaking. The contractor shall work with the provided COR or maintenance personnel in the specific numbers of drains that require camera imagining and snaking. The contractor shall be charge per drainage job for camera imaging and/or snaking. Lastly, the contractor shall provide emergency service to include response time to adhere to the Facilities snaking/unclogging needs. The contractor shall provide a response time of 4 hours upon request from the COR/maintenance personnel. The contractor shall be subject to snake and/or unclog drains at the Facility internal and external of the building sewer piping. There would be at most 12 of the emergency drainage snaking and/or unclogs requirements per contractual yearly period of performance. Item 4 Equipment Condition Assessment The contractor shall perform an inventory listing of the VAMC- Manchester Medical Center equipment list for heating systems, chillers, air handler units, condenser, circulating and heating pumps, fan coil & return fan units, fume exhaust systems, ventilating and air conditioning (HVAC), compressed air, and medical air/vacuum systems. The equipment list shall include equipment item/category, model, serial number, photographs, and location if accessible. The contractor shall provide a detailed written report on the completion of the specified area of the Building and/or Building floor/wing. A life cycle on each equipment shall be recommended from the contractor. The contractor shall recommend a preventative maintenance (PM) scheduling and frequency on each equipment item document and include a parts listing of filters, oil, materials, & etc for the established PMs recommended. It would favor to have the manufacture recommendation/guidance on PM frequency and parts list. The work shall be divide between the base and option years of the service contract, which based upon the agreeance of the contractor and COR. The COR will review the list. The contracting officer will settle disputes between equipment list and the COR validation. The contractor shall identify equipment items not include or in addition. The contractor shall complete this task of equipment condition assessment in a four month timeframe from the agreed upon start date from the contractor and COR. Item 5 Emergency Services (Labor) The contractor shall provide on call services to include labor costs. The vendor will be able to respond to fix issues within four (4) hours. The contractor shall respond within 4 hours for all emergency call backs on the equipment section listed in the above scope of work and to include, but not limited to the equipment items in Attachment A. The equipment sections are as follows. Chillers. Air Handlers units. Condensers. Boilers. Circulating and Heating Pumps. Air Compressors. Fan Coil & Return Fan Units. Medical Air/Vacuum System. Fume Exhaust Systems. The contractor shall provide service labor, materials, and parts necessary to support as needed and emergency calls for repairs and replacements. The contractor shall supply minor parts and materials (<$1,200 per equipment item per year) as needed for necessary upgrades, replacement, and repairs. If cost exceeds the agreed upon limitation (>$1,200 per equipment item per year), then a list of repairs required as a result of the inspection will be provided with a cost proposal for the repair within 24 hours to the COR. Item 6 Materials and Parts The contractor shall supply parts and materials (>$1,200 per equipment item per year) as needed for necessary upgrades, replacement, and repairs. If cost exceeds the agreed upon limitation (>$1,200 per equipment item per year), then a list of repairs required as a result of the inspection will be provided with a cost proposal for the repair within 24 hours to the COR. These costs will be included on the service agreement for anticipating parts and materials for potential repairs and replacements. These equipment section listed in the above scope of work and to include, but not limited to the equipment items in Attachment A. The equipment sections are as follows: Chillers. Air Handlers units. Condensers. Boilers. Circulating and Heating Pumps. Air Compressors. Fan Coil & Return Fan Units. Medical Air/Vacuum System. Fume Exhaust Systems- Mechanical services. Repairs shall be completed within 24 hours after the need for repair has been identified by the contractor or by the COR. All repairs shall be in accordance with the equipment manufacturer s requirements and\or applicable laws, regulations, codes, etc. The Contractor shall furnish all supplies, materials, and equipment to perform regularly scheduled service, emergent service, and repairs. All parts and materials shall be of the original manufacturer s design and specification, or equal thereto. An extension may be granted at the discretion of the COR on a case by case basis. Each request for an extension must include and explanation for the delay, and estimated time of completion, and evidence to clearly show that the contractor has made every effort to repair the system as timely as possible. PERFORMANCE REQUIREMENTS All work shall be completed such that the integrity of the systems is maintained. All work shall be done in accordance with OSHA, EPA regulations, NFPA codes, with particular attention to NFPA 85, VA codes, Federal, State, and local regulations throughout the course of this service contract. The Contractor shall submit technician certification/licensure prior to work start. Copies of these are also to be submitted with the completed checklists. The contractor shall submit all necessary safety plans to include, but not limited to; equipment specific Lock-Out Tag Out procedures, Electrical Safety, plan and SDS for any chemicals used to the COR for approval prior to working at the Medical Center. The contractor shall schedule all site visits, to include emergencies, with the COR. The contractor shall furnish authentic parts from the equipment manufacturer. The determination of when to replace parts is at the recommendation of the technician, with the COR s concurrence. Additional service charges may be incurred to install parts during scheduled inspections or callbacks as specified in this agreement. The contractor shall operate on the premises during the hours of 0700 and 1630, unless otherwise authorized by the COR. The contractor shall respond within 4 hours for all emergency call backs. Work sites shall be left in the same manner of cleanliness and order in which they were found. Vendor will provide their own waste disposal, if any. All vendor technicians performing work on site must report to Facility Service in Building 6 to the contractor badge check in/out room to sign in on the contractor log and get a Contractor badge. Badges must be returned, and log signed out prior to departing the premises. Vendor shall then coordinate with the COR prior to performing their work. Personnel must wear the proper personal protective equipment (PPE) at all times. Work done under this project must comply with infection control requirements. The contractor shall receive all deliveries of materials, equipment, tools, or other goods off of station, and bring them to the job site. The Manchester VA shall not accept deliveries for project purposes. Special care will be taken to secure tools and construction equipment. Material Safety Data Sheets (MSDS s) must be submitted to the COR for approval for all hazardous materials before they are brought to the work site. Two weeks prior notice is required for all work that involves shutting down any of the systems. Work requiring a shutdown may be required to be performed outside of normal working hours. End of day cleanup of the work area(s) is mandatory, and all trash shall be bagged and properly disposed of offsite. Contractor vehicles, including those of their employees, are to be parked in the lower level of Lot D. All travel costs associated with performance of this contract are the responsibility of the Contractor and are provided at no additional cost to the government as part of this contract. Travel costs are defined but not limited to time and vehicle costs for personnel in travel to and from job site for all duties outlined in this specification, normal shipping charges on any parts or materials covered by this contract, costs associated with the normal shipping of parts or equipment out for repair that are covered under this contract, etc. DELIVERABLES Contractor shall coordinate with the COR to provide a complete calendar year schedule for scheduled maintenance tasks at the commencement of the contract. Contractor shall provide a prioritized phone support contact list at the commencement of the contract. Submittal of proposed equipment and materials to be used on site for review and approval by the COR. Submittal of Contractor safety plan and lock\out tag\out plan. Submittal of Safety Data Sheets (SDS) shall be provided by the contactor for all chemicals proposed to be brought to the medical center. Chemicals must be approved before they can be located on property. ATTACHMENTS- EQUIPMENT TABLE Attachment A: Chilled Water Units Equipment/Make: Model: S/N: PM Frequency Location: Trane RAA1004XQ01A3D0NB U04H0T263 Semi-Annual BLDG 7- Roof top York YLAA010SE 11552H1135315 Semi-Annual BLDG 7- Roof top Drake Refrigeration PACT78S3-T4-ZTM D10L1089 Semi-Annual BLDG 1- East-Basement. MRI Room York YCAL0051EC RCTM022574 Semi-Annual Rooftop-15- 3rd Fl- CLC York YCAL0051EC RCTM022572 Semi-Annual Rooftop-15- 3rd Fl- CLC York YCAL0051EC RCTM022571 Semi-Annual Rooftop-15- 3rd Fl- SAC Trane T17 K76307215 Quarterly BLDG 15- D104. CLC Liebert TCSV104-4 C13D2F6701 Quarterly BLDG 1- Basement- E37. Air Handling Units Equipment/Make: Model: S/N: PM Frequency Location: York ZF078E2452UAA5A NID3603353 Quarterly Rooftop-15- 3rd Fl- Solarium Trane TSC092AROA327H 803100927L Quarterly Rooftop-18 BLDG 18 Energy Pack//Venmaries A-2-14E-PP-HW-DX-X-C 00782937-C05584. Quarterly Rooftop-18 BLDG 18 Trane MCCA017UBOA00000U K00A17077 Quarterly BLDG 1- E504. Trane CSAA030UBC00 K12LO4957A Quarterly 5th Floor Rooftop- OR AHU Trane N05 K99626181M Quarterly BLDG 1- W439 York XTI-045X075-EAKA017A CFBMXX0180 Quarterly BLDG 1- W105. Munters Corporation PV-MZP-8703-PVH 21225368 Quarterly Rooftop 1- SPS AHU. Trane TCPA0DO123M3344SB10 M20E00078 Quarterly Rooftop- CSB BLDG Trane TCK151C30ABB 52510260D Quarterly Rooftop- Pharmacy Trane SSHF204CA37C4CD9011 C07L12189 Quarterly Rooftop- Radiology. Trane CSAA00FVAC00 KIIA08729 Quarterly Rooftop- Radiology/MRI. Trane TWE120E300AA 10484TT28A Quarterly Rooftop- Radiology/MRI. ZZGENERAL ELECTRIC WE192B3 A Quarterly BLDG 1- N121. T&E Trane T6 K6E307508 Quarterly BLDG 15. D125 Trane T6 K6E307509 Quarterly BLDG 15. D125 McQuay RPS035DLS FB0U110300806 Quarterly BLDG 15. D125 York XTO-063X099-JNMK017A CCTMXT0225 Quarterly Rooftop-15 SAC Addition Trane TSC102A3R0A27 734101389L Quarterly Rooftop-18 JCI J30YDC00A2BAA2A N1E77502 Quarterly Rooftop-18 Trane SSHFF20C C07L12180 Quarterly Rooftop-18 Condenser Units Equipment/Make: Model: S/N: PM Frequency Location: Trane RAUCC30EBR03ABDFOOO10 C98M00489 Quarterly Rooftop-18- BLDG 18 Trane AUJC50EB C13F03568 Quarterly Rooftop-18- BLDG 18 Trane RAUJC30EBD13A0DF0001 C20803693 Quarterly Rooftop- MH BLDG Trane J30YDC00A2BAA2A N1E7750283 Quarterly Rooftop- Radiology. Bryant 558DPX150000CA 4593G04233 Quarterly Rooftop-18 Carrier Air Cond Group 50DJ028500AC 0496F88041 Quarterly Rooftop-18 Boiler/Hot Water Heater Units Equipment/Make: Model: S/N: PM Frequency Location: Boiler/LAARS NTH750NJX3 G13249551 Annual Rooftop-18- BLDG 18 Boiler/LAARS NTH750NJX3 G13249553 Annual Rooftop-18- BLDG 18 Boiler/Dri-Steem GTS-400 128839-01 Annual Rooftop- CSB BLDG Hot Water Heater/Rinnai LU199IN LL.BA-125525 Annual Rooftop- CSB BLDG Hot Water Heater/Rinnai LU199IN LL.BA-125980 Annual Rooftop- CSB BLDG Boiler/Bosh A23S3123 A Annual BLDG 6- Basement Boiler/Burham Furnace ALP285F-2L07 A Annual BLDG 3- Basement Boiler/Burham Furnace ALP285F-2L07 65283384 Annual BLDG 4- Basement Boiler/HTP EFT-285 07179F10323215 Annual Rooftop- CSB BLDG Boiler/HTP EFT-285 A Annual Rooftop- CSB BLDG Circulating Pumps Equipment/Make: Model: S/N: PM Frequency Location: Electric Motor: Chilled Water/Baldor Electric Super E Motor F1206271539 Annual BLDG 1- 7th Floor Electric Motor: Chilled Water/Baldor Electric Super E Motor F1206271389 Annual BLDG 1- 7th Floor Electric Motor: Chilled Water/Baldor Electric Super E Motor F1206152648 Annual BLDG 1- 7th Floor Electric Motor: Chilled Water/Baldor Electric Super E Motor F1206152718 Annual BLDG 1- 7th Floor Electric Motor: Chilled Water/Baldor Electric Super E Motor F1109012534 Annual BLDG 1- 7th Floor Pump-circulating/Reitschle Thomas VAC02106 2634207 Annual BLDG 1- 7th Floor Heating Pump/Taco F13011E4HAJ1LOAB1973D 09J359Z91061-1 Annual BLDG 1- 7th Floor Heating Pump/Taco F13011E4HAJ1LOAB1973D 09J359Z91061-2 Annual BLDG 1- 7th Floor Pump-circulating/Taco Super E Motor F1302080003 Annual BLDG 1- 5th Floor- N567 Pump-circulating/Taco Super E Motor F1302080003 Annual BLDG 1- 5th Floor- N567 Pump-circulating/Taco 191E1E1 7190 Annual Rooftop- CSB BLDG Pump-circulating/Taco 191E1E1 7190-1 Annual Rooftop- CSB BLDG Additional Equipment- Air Compressors, Medical Air/Vacuum Systems, Fume Exhaust Systems Equipment/Make: Model: S/N: PM Frequency Location: Medical Air Dryer/ Hankison DW-13 10GDHHW3154 Semi-Annual SPS- BLDG 1- N261. Return Fan A A Quarterly BLDG 1- E504. A/C Supply A A Quarterly BLDG 1- E406 Return Fan A A Quarterly BLDG 1- E406 Return Fan A A Quarterly BLDG 1- W439 Return Fan/ GreenHeck BSQ-200N30NX 13056259 Quarterly BLDG 1- E105. Air Compressor/ Sullair ES6-10H/A 201104170007 Quarterly BLDG 1- 7th Floor Air Compressor/ Sullair ES6-10H/A 201103240082 Quarterly BLDG 1- 7th Floor Fume Exhaust System/ TriStack BS00218 11731-01-1 Quarterly Rooftop- Pharmacy Fume Exhaust System/ TriStack BS00218 11731-01-2 Quarterly Rooftop- Pharmacy Clean Steam Generator/ Cemline V16055G1230 65664 Semi-Annual BLDG 1- N121. T&E Fan Coil Unit/ Air control Products 5WS120B None Quarterly BLDG 15- D104. Fan Coil Unit/ Trane TWE060D150BQ 3132WXW2 Quarterly BLDG 15-Room 6 Fan Coil Unit/ Trane TWE060D150BQ 3132WXW2 Quarterly BLDG 15-Room 6 Medical Air System/ Beacon Medes 4107005565A A A A A A HOP401540 Quarterly BLDG 1- 7th Floor Medical Vacuum System/ Beacon Medes 4107108454A A A A A A HOP301808 Quarterly BLDG 1- 7th Floor Medical Air Dryer/ Hankison DW-13 10GDHHW3154 Semi-Annual SPS- BLDG 1- N261. END OF STATEMENT OF WORK

Post-Bid

Medical

Public - Federal

Service, Maintenance and Supply

We’ve obtained documents for this project and are currently processing them.

Subscribe For Documents

3 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
301
Active Projects
192
Bidding Soon
2,400
All Active Projects
1,066
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

September 13, 2023

October 13, 2023

img_map_placeholder

718 Smyth Rd, Manchester, NH

The best commercial construction data available. Period.

Access Now

Get the right
data with Project Intelligence

Share with your network.

Project Shared

with

example@example.com

Upgrade now for industry‑leading commercial construction data.

You've reached the free-view limit.

Thousands of projects are added every week - don't miss out. Explore the best product options for your business and subscribe today.

Get Access Now

Choose what you would like to do.

Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.