Site work and paving for a sidewalk / parking lot in Dutch John, Utah. Completed plans call for site work for a sidewalk / parking lot.

Award Details Contract Award Date: Jun 09, 2022 Contract Award Number: 140R4022P0048 Task/Delivery Order Number: Contractor Awarded Unique Entity ID: NWU4L5Y16LK5 Contractor Awarded Name: T.D.MCGHEE CO. Contractor Awarded Address: Wilmington, NC 28411-4771 USA Base and All Options Value (Total Contract Value): $77300 The U. S. Bureau of Reclamation, Flaming Gorge Field Division (FG), has drainage and erosion problem in the power plant parking area. The section of riverbank of concern is located below Flaming Gorge Dam on the east side of the river a short distance downstream of the 66-inch hollow-jet valves. This area has seen significant erosion over the years primarily due to operation of the hollow-jet valves and runoff from the employee parking space during significant rain events. To mitigate this issue Reclamation requires installation of a 3 reinforced concrete wall with a 3 chain link fence to include barbed wire. In addition, Reclamation needs a rock void filled. Flaming Gorge is located approximately 40 miles North of Vernal, Ut on Hwy 191. (Please see pictures at the end of SOW.) The Contractor shall provide the labor, tools, equipment, transportation, materials and expertise necessary to install a reinforced concrete wall with a 3 chain link fence and barbed wire. In addition, filling the designated rock void next to the spillway outlet. Concrete Wall Installation of a 12 wide x 3 above ground level x 215 long poured steel reinforced concrete wall with new 3 tall chain link fence topped with 3 strands of barbed wire along the length of the employee parking area. The wall will provide a barrier between parked vehicles and the riverbank. (Photo #2) Excavate and pour footings to support the concrete wall. Footing shall be below the frost line. Excavated material shall be used to back fill the back side of the new wall. The top of the wall shall be 3 above the parking lot grade the back side can be filled up close to the top All reinforcement steel shall be #5, (5/8 ) The concrete shall be 3000 PSI minimum strength. Concrete surfaces shall be smooth troweled finish. See Attachment 591-421-1552 parking lot barrier plan concrete wall details. Fencing Install 3 high chain link fence on top of concrete wall to include 3 strands of barbed wire on top of the chain link fencing. The new chain link fence must be the same height when connecting to the existing fencing at the at the bottom of the power plant and the top of the parking lot at the security fencing Rock Void Fill rock void with concrete. (Please see photo 3 and 4) The concrete shall be 3000 PSI minimum strength. All concrete surfaces shall be smooth troweled finish. The Contractor will comply with the attached State of Utah Department of Natural Resources Stream Alteration Permit 20-41-01SA Dated 9 June 2020 when filling the rock void. 3. Deliveries, Storage, and Protection Supplies shall be delivered during normal work hours Monday thru Thursday, except federal holidays, 7:30 AM to 5:00 PM to the Flaming Gorge Warehouse, 575 So Blvd, Dutch John, Ut 84023. Please notify COR of all deliveries at least 48 hours prior. The Contractor is responsible for all shipping cost. The Flaming Gorge Power Plant has limited space for Contractor s equipment and material in the power plant parking lot area. The Contractor shall leave access for Government vehicles to always have access power plant. Arrangements must be made prior to the start of work with the COR and CO to discuss the site usage. Concrete delivery must be arranged with COR prior 48 hours prior to delivery. All material shall be protected from corrosion, deformation, and other types of damage. Remove and replace damaged items with new items. Delivery Location Code: 0009910009 Bureau of Reclamation-UC-FGFD Flaming Gorge Field Division 5995 Flaming Gorge Visitor Center Dutch John UT 84023-0278 US 00010 Parking Area Wall Product/Service Code: Z1LZ Product/Service Description: MAINTENANCE OF PARKING FACILITIES Period of Performance: 04/29/2022 to 05/06/2022 The magnitude of construction for this project in accordance with 36.204 is between $25,000 and $100,000 as per addendum 1.

Award

Sidewalks / Parking Lot

$77,300.00

Public - Federal

Paving, Site Work

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

Subscribe For Documents

3 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
3
Active Projects
1
Bidding Soon
47
All Active Projects
13
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

April 15, 2022

May 6, 2022

img_map_placeholder

5995 Flaming Gorge Visitor Ctr, Dutch John, UT

Related To This Project


The data you need to build the relationships you want. Try it free.

Access Now

Get the right
data with Project Intelligence

Share with your network.

Project Shared

with

example@example.com

Upgrade now for industry‑leading commercial construction data.

You've reached the free-view limit.

Thousands of projects are added every week - don't miss out. Explore the best product options for your business and subscribe today.

Get Access Now

Choose what you would like to do.

Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.