Privately Funded
Bidding Soon
Documents Available
Publicly Funded
Addenda Available
Post-Bid
Saving Project...
Renovation of an educational facility in Gleason, Tennessee. Completed plans call for the renovation of a educational facility.
Any questions concerning the bid should be directed to John Liggett, Director of Finance (731-364-5429), or Wayne Reynolds, Supervisor of Maintenance (731-364-2578). Bids must be sealed and marked on the outside of the envelope: "SEALED BID#2024-09, PARTIAL ROOF REPLACEMENTS - GLEASON SCHOOL" Nothing herein is intended to exclude any responsible vendor, his or her product or service, or in any way restrain or Any questions concerning the bid should be directed to John Liggett, Director of Finance (731-364-5429), or Wayne Reynolds, Supervisor of Maintenance (731-364-2578). restrict competition. On the contrary, all responsible vendors are encouraged to offer a proposal. Weakley County is compliant with Title VI of the 1964 Civil Rights Act and as a result, does not discriminate on the grounds of race, creed, Total Square Footage: 4,365 - BASF Preferred - Remove all surface contaminants or other substances that may interfere with proper adhesion of new materials utilizing high-pressure water with a minimum pressure rating of 2,500 PSI around the perimeter edges only. - The existing roof will be scarified to remove 3/4 to 1" of the existing polyurethane foam roof. - The existing roof should be inspected; if areas are found to have bad decking, they should be removed and replaced. - The roof should be primed prior to installing the new polyurethane foam. - All roof top mechanical equipment, piping, vents, etc. should be masked prior to foaming. - Apply closed cell spray polyurethane foam. The average thickness of the foam should be 1.5 inches. It should be applied uniformly over the specified roof surfaces with a tolerance of plus or minus 1/4 " per inch of thickness, except where variations are required to ensure proper drainage or to complete a feathered edge. - Apply High Solids silicone base coat over the polyurethane foam. The silicone coating should be applied according to manufacturer specifications to achieve a minimum dry film thickness at approximately 10 mils. Allow the coating to cure. Inspect for thinly coated areas, uncured areas, or other defects. Any defects should be repaired prior to subsequent application of coating. The base coat should be clean, dry, sound, and free of dust, dirt, and other contaminants before application of the topcoat. - Apply High Solids silicone topcoat in a timely manner upon completion of base coat to insure proper adhesion between coats. The topcoat should be applied per manufacturer specifications to achieve a minimum dry film thickness at approximately 10 mils. - Apply ceramic granules @ 30 lbs. per square broadcast into the wet topcoat for proper granule adhesion. - After all the work is complete, remove all job-related debris and surplus materials and leave the premises in a neat and orderly condition. - The new roof system should be fire rated class "A" per UL 790. The Roofing System shall be BASF Preferred and qualify for the manufacturer's ten-year (10) guarantee. The roofing guarantee shall include labor and materials. Payment will be held or a 5% retainage until the guarantee has been presented to the Director of Finance. national origin or gender. Bids may be hand delivered or mailed to: John H. Liggett Director of Finance Weakley County, Tennessee 8319 Highway 22, Suite B Dresden, TN 38225
Award
Educational
$34,700.00
Public - County
Renovation
Documents for this project are exclusively Specifications. If Plans become available, we will add them here.
3
Trades Specified
Division 00 - Lorem Ipsum
Find More Local Projects
Within 75 Miles of This Project
One Low Price
- One license and one market
- Details and key contacts on all bidding projects
- Organize your pipeline with a digital bid board
- Automatically match opportunities to your profile
- Saved searches deliver daily project leads to your email inbox
Market Pricing Around
- All Starter Product functionality
- Access to all documents (plans, specifications, and addenda)
- Access to planning projects
- Access to contact information
- Ability to Export
You’ve Reached the Free View Limit
Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.
Come back in [[refresh_days]] to get [[project_count]] more free projects.
October 11, 2023
November 1, 2023
3 State Championship Rd, Gleason, TN
Related To This Project
Gleason, TN
Bid Date: Apr 04 2024
Gleason, TN
Bid Date: Apr 16 2024
Gleason, TN
Bid Date: May 03 2024
Gleason, TN
Bid Date: Nov 08 2024
Gleason, TN
Bid Date: Sep 03 2020
Gleason, TN
Bid Date: Oct 26 2022
Knoxville, TN
Bid Date: Oct 24 2023
Gallatin, TN
Bid Date: Oct 12 2023
Blountville, TN
Bid Date: Oct 11 2023
Collierville, TN
Bid Date: Oct 11 2023
Collierville, TN
Bid Date: Sep 27 2023
Knoxville, TN
Bid Date: Oct 13 2023
Johnson City, TN
Bid Date: Oct 17 2023
Athens, TN
Bid Date: Oct 10 2023
McMinnville, TN
Bid Date: Jan 30 2024
Recently Viewed
--
--
--
--
--
--
--
--
--
--
Stop wasting time. Get and stay ahead of your competition.
Get instant access to the most complete and actionable commercial construction data available. Try it for free.
Get the right
data with Project Intelligence
Project Shared
with
example@example.com
Choose what you would like to do.
Seen enough? Want to see more? Subscribe on your own or talk to one of our sales reps.
What is your business type?
We have a wide variety of products that are purpose built for certain business types.