Renovation of a detention facility in Memphis, Tennessee. Completed plans call for the renovation of a detention facility.

*The purpose of this amendment is to respond to the questions regarding this request and to extend due date to 4/30/2025 11a central. Qand A below, Pictures attached What are the exact dimensions of the existing door and frame For example, height, width, thickness. Door: 35 & 5/8th inches wide by 83 inches tall by 2 inches thick Door Frame: 40 inches wide by 87 1/2 inches tall. Frame appears to be a standard steel door frame for commercial building applications Is the door left-hand or right-hand swinging Inward or outward opening Door has a left-hand swing and opens inward into the cellblock What security rating or classification is required For example, minimum gauge, ASTM F1450 compliance There are no markings on the door, but his door is a high security steel door used for correctional applications. I would assume the door follows the USMS guidelines regarding confinement/prison usage. Should the replacement door and frame match any existing finish or material specifications Door must be steel with stainless steel hardware Can you confirm the type/model of existing hardware being reused like the locks, hinges, closers Hinges are high security & heavy duty tamper-proof stainless-steel hinges Lock may be a Southern Folger brand with an electromechanical mortise style deadlatch with Mogul cylinder used for confinement facility applications. (photos attached) Door closers are conceal mounted high security & heavy-duty closure devices, brand unknown Are there any anchoring or wall condition specifications such as concrete or CMU Wall structure appears to be a solid concrete wall with a tile facade. Is a fire label required for the new door and frame None of the installed doors have a fire label attached. However, this door is a direct access to a stairway and fire code usually requires these doors to be fire/smoke rated. P see attached SF1449 for Technical Specifications/Statement of Work If submitting a quote be sure to include completed and sign attached SF1449. Sign the first page, requirements are on page 4, p provide pricing there. Thank you NOTE in Subject of email: FFY25 D76 Memphis Detention Door Replacement - 15M102254700104 Email Completed quote to renee.leaman@usdoj.gov by 17 APRIL 2025 1100 CST NOTE: Vendor MUST be IPP compliant before awarded see page 22 of SF1449 Attachment/Links Place of Performance Odell Horton Federal Building 167 North Main Street Room 1072 (Cellblock) Memphis, TN 38103 Base : May 1st, 2025 - April 30 2026 The Method of Contractor Selection has not been determined at this Time

Post-Bid

Jails / Prisons

$300,000.00

Public - Federal

Renovation

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

7

Subscribe For Documents

3 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
0
Active Projects
0
Bidding Soon
0
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

April 30, 2025

May 1, 2025

Project location map

167 N Main St, Memphis, TN

Related To This Project


Recently Viewed

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.