BLOCK PAGE!!!
Get Full Details

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Published June 25, 2025 at 8:00 PM

Updated March 31, 2026

Site work for a municipal facility in Boulder, Colorado. Completed plans call for site work for a municipal facility.

Reference Number 0000389228 The new Mountain Rescue Building will utilize a Ground source heat pump mechanical system. 24 vertical boreholes will be needed for this Geothermal system. One Test well has been installed on the which will become one of the permanent boreholes for the system. The drilling contractor is responsible for drilling 23 vertical boreholes. Buyer Preferences, Guidelines & Requirements General Requirements - Insurance Questions Due Deadline 06/13/2025 at 2:00 PM MT s are submitted online No, To contact Boulder County Purchasing or ask s in relation to this proposal, respondents register on online and initiate the communication electronically through the Vendor Discussions or the Ask a feature. SCOPE OF WORK A. Reference 2.02A. B. The extent of ground heat exchanger work is indicated on the drawings and schedules, and by requirements of this section. The closed-loop ground heat exchanger consists of heat fusion joined high density polyethylene piping, to couple to the extended range water-source heat pump units to provide an ISO/ARI/ASHRAE 13256-1 (water/air) and ISO/ARI/ASHRAE 13256-2 (water/water) ground source closed-loop heat pump system. Extended range for the ISO/ARI/ASHRAE 13256-1/2 is defined for testing purposes as 32_F EWT for heating and 77_F EWT for cooling. Any extended range heat pump considered for this application have performance tables detailing total cooling and heating capacity, heat rejection (cooling), heat absorption (heating), kw consumed and EER/COP in 10_F EWT increments, from 20_F to 110/120_F source water temperature. For each 10_F EWT increment, performance values shall be provided at three supply water flow rates with corresponding pressure drop data through the coaxial heat exchanger of the heat pump. Water source heat pumps intended for open loop and boiler/chiller systems, which are rated at narrower EWT ranges on the ISO/ARI 13256-1/2 specification, are unacceptable. INTENT These Specifications are intended to define the contractor's Scope of Work, establish the quality and safety requirements, and set general precautions to protect further construction of the project. Incidental items not specified therein or not shown on the drawings but which are and necessary to complete the work shall be furnished by the contractor in the best available quality. WORK COMPLETED BY OTHERS Any and all work not directly relating to the installation of the Closed-Loop Ground Heat Exchanger, as described in these Specifications and Drawings, shall be provided. The location of the Closed-Loop Ground Heat Exchanger connection to the building heat pump system and the Terminal Point of Piping is shown on the drawing, or as defined by Mechanical Engineer. Refer to drawings.

Post-Bid

Municipal

$400,000.00

Public - County

Site Work

4

7

2

2

Subscribe For Documents

2 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
74
Active Projects
9
Bidding Soon
1,058
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

June 23, 2025

July 23, 2025

Project location map

3720 Walnut St, Boulder, CO

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.