BLOCK PAGE!!!
Get Full Details

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Published July 16, 2025 at 8:00 PM

Updated July 18, 2025

Renovation of a medical facility in Dickinson, Texas. Completed plans call for the renovation of a medical facility.

The TDCJ is seeking bids for the automation of the HVAC system at the Carol S Young Medical Facility in Texas City, Texas, to include all expenses for material and labor. The Vendor shall provide routine equipment and services for the replacement, and removal of existing equipment, installation, delivery, start-up, and training of the Department personnel. The Vendor shall comply with the Department's reporting procedures. Scope of Work to be performed by the Department personnel: o Provide oversight of the project. o Inspect, approve, and accept equipment once installation, set-up, and start-up is completed. Mandatory registration for the site visit must be submitted by email on or before June 23, 2025, and no later than 4:00 PM CDT The HUB Goal for this category is therefore identified as - 32.9% Provide and install a new direct digital controls (DDC) Automation monitoring system. o Demo any existing automation system currently installed. o Graphics, O&M manuals, commissioning, and a 1-year warranty as part of this scope of work, warranty does not extend to equipment not provided under this scope of work. o Controls Contractor will provide Server, Workstation, and Controllers to meet specifications for the central plant as outlined below. o Controls Contractor must provide master Level Certification to perform this work. o Examples: Ecostruxture Schneider Electric, or Honeywell N4 JACE, or TDCJ Approved Alternative. Central Plant Scope of Work: o Controls Contractor will provide the controls/monitoring for (2) Chiller Systems (Chiller-1, Chiller-2, PCHWP-1, PCHWP-2, SCHWP-1, SCHWP-2, CDWP-1, CDWP-2, CDWP-3) points included: o (2) Chiller Start/Stop o (2) Chiller Status (Amps) o (2) Chiller General Alarm o (2) Chiller CHW Supply Temperature o (2) Chiller CHW Return Temperature o (2) Chiller CDW Supply Temperature o (2) Chiller CDW Return Temperature o (2) Primary CHW Pump Start/Stop o (2) Primary CHW Pump Status (Amps) o (2) Secondary CHW Pump Start/Stop o (2) Secondary CHW Pump Status (Amps) o (2) Secondary CHW Pump VFD Speed Output o (3) CDW Pump Start/Stop o (3) CDW Pump Status (Amps) o (2) CDW Isolation Valve Command o (2) CDW Isolation Valve Feedback o (1) Chilled Water Building Supply Temp o (1) Chilled Water Building Return Temp o (1) Outside Air Temperature o (1) Chilled Water Loop Differential Pressure Controls Contractor will provide the controls/monitoring for (2) Cooling Towers (CT-1, CT-2) points included: o (2) Cooling Tower Start/Stop o (2) Cooling Tower Status (Amps) o (2) Cooling Tower VFD Speed (New Drive Provided and Installed by Controls Contractor) o (1) Cooling Tower Bypass Valve (Existing) o Controls Contractor will provide the controls/monitoring for (2) Boilers (Boiler-1, Boiler-2) points included: o (2) Boiler Start/Stop o (2) Boiler Status (Amps) o (2) Boiler General Alarm o (2) Boiler Recirc Pump Status o Controls Contractor will provide the controls/monitoring for (2) Hot Water Pumps (HWP-1, HWP-5) points included: o (2) HW Pump Start/Stop o (2) HW Pump Status (Amps) o (2) HW Pump VFD Speed Output o (1) Common HW Supply Temp o (1) Common HW Return Temp o (1) Hot Water Loop Differential Pressure o Controls Contractor will provide the controls/monitoring for (4) Fan Coil Units (FCU-1, FCU-2, FCU-3, FCU-4) points included: o (4) Fan Start/Stop o (4) Fan Status (Amps) o (4) HW Valve Control (Existing) o (4) CHW Valve Control (Existing) o (4) Space Temperature o Controls Contractor will provide the controls/monitoring for (1) Refrigerant Monitoring System points included: o (1) Refrigerant Monitoring Alarm Input o (1) Exhaust Fan 1.15 High Speed o (1) Exhaust Fan 1.15 Low Speed o Controls Contractor will provide the controls/monitoring for (1) General Exhaust Fans (EF-1.14) points included: o (1) Fan Start/Stop o (1) Fan Status north Pod Scope of Work: Controls Contractor will provide the controls/monitoring for (1) VAV Air Handling Units (AHU 2-2), points included: o (1) Fan Start/Stop o (1) Fan Status (Amps) o (1) Fan Status (Amps) o (1) CHW Valve Control o (1) VFD Speed Control o (1) Return Air Temperature o (1) Return Air Humidity o (1) Mixed Air Temperature o (1) Supply Air Temperature o (1) Outside Air Damper Control o (1) Return Air Damper Control o (1) Face Damper Control o (1) Bypass Damper Control o (1) High Static Cutout o (1) Low Static Cutout o (1) Pre-Filter DP o (1) Final Filter DP o (1) Smoke Purge Input o (1) Freeze Stat o (1) Duct Static Pressure o (1) Condensate Float Pan Switch East Pod Scope of Work: Controls Contractor will provide the controls/monitoring for (1) VAV Air Handling Units (AHU 3-2), points included: o (1) Fan Start/Stop o (1) Fan Status (Amps) o (1) Fan Status (Amps) o (1) CHW Valve Control o (1) VFD Speed Control o (1) Return Air Temperature o (1) Return Air Humidity o (1) Mixed Air Temperature o (1) Supply Air Temperature o (1) Outside Air Damper Control o (1) Return Air Damper Control o (1) Face Damper Control o (1) Bypass Damper Control o (1) High Static Cutout o (1) Low Static Cutout o (1) Pre-Filter DP o (1) Final Filter DP o (1) Smoke Purge Input o (1) Freeze Stat o (1) Duct Static Pressure o (1) Condensate Float Pan Switch o Controls Contractor will provide the controls/monitoring for (1) Exhaust Fan (EF 3-2), points included: o (1) Fan Start/Stop o (1) Fan Status (Amps) o Controls Contractor will provide the controls/monitoring for (12) VAV Boxes, points included: o (12) Space Temperature o (12) HW Valve Control o (12) Supply Air Temperature o (12) Damper Control o (12) Pressure Velocity

Post-Bid

Medical

$300,000.00

Public - State/Provincial

Renovation

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

5

Subscribe For Documents

5 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
320
Active Projects
76
Bidding Soon
3,423
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

July 17, 2025

August 18, 2025

Project location map

5509 Attwater Ave, Dickinson, TX

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.