BLOCK PAGE!!!
Get Full Details

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Published August 6, 2025 at 8:00 PM

Updated August 7, 2025

Renovation of a military facility in Eglin, Florida. Completed plans call for the renovation of a military facility.

Multiple (5) air conditioning units are currently not working and need repair before more of the units fail due to strain. At a minimum, the Contractor shall accomplish the requirements of this order through fulfilling the following specifications: Replace the evaporator coils on unit A, H, G and F. Replace the compressor on unit G, and replace the condensing fan motor for unit J. Pull units A, F, H, and G into a vacuum, and charge according per manufacturers specifications.. DELIVERABLES Unit A: Replace Evaporator Coil and Recharge Install New Evaporator Coil (Up flow A-Coil) Recharge the system with R410A Evacuate the system to remove impurities prior to recharge Type of Unit- Exterior Wall Brand- Bard Serial numbers- 278J1936739-02 Tonnage- 3 Unit F: Replace Evaporator Coil and Recharge Install New Evaporator Coil (Up flow A-Coil) Recharge the system with R410A Evacuate the system to remove impurities prior to recharge Type of Unit- Exterior Wall Brand- Bard Serial number-278J193671749-02 Tonnage- 3 Unit G: Refrigerant Leak at evaporator has caused it to lose all the Refrigerant Compressor is inoperable Install New Evaporator Coil (Up flow A-Coil) Evacuate the system to remove impurities prior to recharge Recharge the system with R410A Replace 2.0 Ton Compressor Change Out 1 Phase to include: Up to 8lbs of refrigerant Drier replacement Capacitor replacement Refrigerant Recovery 1/2HP-1/6HP, 1075/240V Rescue Blower Motor Replace an inoperative blower motor Type of Unit- Exterior Wall Brand- Bard Serial number- 278J193671742-02 Tonnage- 3 Unit H: Replace Evaporator Coil and Recharge Install New Evaporator Coil (Up flow A-Coil) Recharge the system with R410A Evacuate the system to remove impurities prior to recharge Type of Unit- Exterior Wall Brand- Bard Serial number- 278J193671745-02 Tonnage- 3 Unit J: Condenser Fan Motor is Inoperable Replace Condensing Fan Motor w/ capacitor Condenser Motor 825 RPM Replacement of 825 RPM condenser fan motor w/new capacitor Open system disconnects, check electric power "OFF", remove old motor & capacitor, install new, check fan operation Type of Unit- Exterior Wall Brand- Bard Serial number- 278J193671740-02 Tonnage- 3 All questions are due no later than 5:00 PM CST, July 15, 2025. If your company is capable of providing this item, quotes and any product literature must be received no later than 2:00PM CST, July 22, 2025 3. If you have any questions pertaining to this matter, please contact Naomi Letting by email at naomi.letting@us.af.mil Urgent air conditioner repair at Duke Field 96 th TW (15312) facility that has no current maintenance contract

Award

Military

$21,560.00

Public - Federal

Renovation

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

3

Subscribe For Documents

3 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
105
Active Projects
49
Bidding Soon
797
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

July 22, 2025

August 21, 2025

Project location map

To Be Determined, Eglin, FL

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.