BLOCK PAGE!!!

Get Full Details

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Saving Project...

Published May 19, 2026 at 8:00 PM

Updated May 20, 2026

Site work for a fire / police facility in Homestead, Florida. Completed plans call for site work for a fire / police facility.

Contractor to provide the necessary permits, materials, equipment, and labor to accomplish the following: The work generally consists of the installation of approximately 7,900 linear feet of 9-gauge galvanized post driven chain-link fencing, including a top tension wire and a 12-inch, three-strand barbed-wire extension, along with twelve (12) new gates. Additionally, approximately 1,750 linear feet of three-strand barbed wire will be added to existing fencing. Contractor must refer to the Request for Price Quotation (RPQ) and associated project documents for the detailed scope of work. At the time of bid, the bidder and all subcontractors must hold a valid, current, and active State and/or Miami-Dade County contractor's license consistent with the requirements of the scope of work. Registering as a vendor must be done via Miami-Dade County's web-based vendor registration portal. Fence Specifications: 1. Chain Link Fence 6' high fabric with 12" barbed wire. (total 7') 2. Fabric: 9 gauge galvanized 2" diamond mesh. Class 2 zinc coating or equivalent corrosion protection. 3. Tension Wire: No. 7 gauge zinc galvanized. 4. Line Posts: 1 7/8" OD Schedule 40. Post driven in limerock. 5. Terminal / Corner / Pull Posts: 2 3/8" OD Schedule 40. Concrete backfill. 6. Post Spacing: Line posts 8', Pull Post every 150-200' 7. Brace Bar: 1 5/8" OD galvanized 8. Truss Rod: 3/8" galvanized 9. Barbed Wire: 12.5 gauge, 3 strand zinc coated or equivalent. C. Scope of Work: 1. Refer to sheet A-1.0 and A-2.0 for details on fencing location and technical drawings. 2. Contractor shall provide all necessary equipment for clearing, grubbing, grading and removal of debris for the fence line or any required clear areas adjacent to the fence. 3. Contractor shall demolish and dispose of approximately 1,200 LF of existing fence. Location will be identified at the site. 4. Contractor shall set posts plumb in accordance with (IAW) ASTM-F567 standards. Terminal posts, Corner Posts, Pull Posts, and Gate Posts shall be set in concrete. Line Posts can be post driven my mechanical means. 5. Line Posts shall be installed at intervals not exceeding 8' on center. Pull Posts shall be installed every 150'- 200' with appropriate Brace bar and Truss Rod installed. 6. Contractor shall install the tension wire 4 in. down from the top of the fabric. Tension wire to be stretched taut, independently and prior to the fabric, between the terminal or pull posts and secured using a brace band. Tension wire shall be secured to chain link fabric and line posts with appropriate tie wire. 7. Tension wire can be installed through the barbed wire arm for extra support if necessary. 8. Contractor shall install the Chain Link Fabric and required hardware IAW with ASTM-F567 standards. 9. Barbed wire shall be stretched tout between tension / pull posts. Barbed wire brackets arms shall face outward (away from property) at a 45deg angle. 10. Contractor shall provide and install (7) new galvanized steel frame chain-link swing gates IAW with ASTM-F567 to include heavy terminal posts and concrete footings, hinges, drop rods, and wheels. Gates shall be plumb in the closed position. 12" of barbed wire shall be securely mounted vertically to the top of the swing gates. Refer to sheets A-1.0, A-2.0 for location and specifications 11. Direction of all swing gates shall be inward and not to interfere with vehicle circulation. Contractor shall notify MDFR project manager in the event a swing gate poses an interference to traffic or vehicle circulation. 12. Contractor shall provide and install (1) new manually operated galvanized steel frame chainlink cantilever gate with 12" barbed wire. Refer to sheet A-1.0, A-2.0 for location and specifications. 13. Contractor shall provide and install a commercial strong arm double gate latch with a cutresistant locking mechanism. 14. Contractor shall provide and install (3) motorized and (1) manual vehicle rolling gates. Refer to sheet A-1.0, A-2.0 for location and specifications. 15. Motorized rolling gates shall be solar powered with imbedded electrical conduits for future power and data supply. 16. Final pedestal and solar panel location will be coordinated between the Contractor and MDFR Project Manager at each gate location. 17. Contractor shall add additional barbed wire and mounting brackets to +-1,750 liner feet of existing chain link fencing. Refer to sheet A-1.0, A-2.0 for location and specifications. The last day for project RFI QUESTIONS is on Thursday, April 30, 2026 at 5:00 PM

Post-Bid

Fire / Police

$515,000.00

Public - County

Site Work

4

3

2

Subscribe For Documents

3 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
200
Active Projects
91
Bidding Soon
1,694
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

May 14, 2026

June 8, 2026

Project location map

914 St Nazaire Blvd, Homestead, FL

Related To This Project


Recently Viewed

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.