Get Full Details

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Saving Project...

Published November 9, 2026 at 7:00 PM

Updated November 15, 2026

Renovation of an educational facility in E Sandwich, Massachusetts. Completed plans call for the renovation of a educational facility.

Fire alarm panel upgrades for the Sandwich Public Schools. Detailed Scope of Work 2.1 Fire Alarm Control Panel Upgrades The Contractor shall upgrade the existing fire alarm control panel system as follows: o Remove and replace the existing CPU controller with a new Simplex 4100ES CPU controller. o Furnish and install all associated power supplies required for the upgraded configuration. o Upgrade the existing MAPNET communication boards to new IDNET-compatible boards. o Verify compatibility of existing system components with the upgraded control equipment. Replace designated field devices that are incompatible with the new IDNET configuration, as identified in this scope. o Perform all required system programming, configuration, addressing, and database modifications necessary to support the upgraded equipment. o Preserve existing system functionality, including alarm reporting, supervisory signals, trouble signals, notification functions, and interfaced equipment, as applicable to the existing system. 2.2 Audio System Upgrade The Contractor shall upgrade the existing fire alarm audio control equipment as follows: Remove and replace the existing analog audio controller with a new digital audio controller. Remove and replace the associated existing audio amplifiers with compatible digital-system amplifiers. o Provide all necessary components, connections, programming, and configuration required for proper operation. o Verify proper operation of the upgraded audio system, including applicable alarm notificationand voice communication functions.The Contractor shall furnish and install surge protection as follows: Install surge protection at all three existing fire alarm system node panels. Install surge protection on the external garage IDNET loop. Coordinate the installation with the existing system configuration and manufacturer requirements. Verify that the surge protection is properly installed, grounded, and compatible with the associated circuits and equipment.

Sub-Bidding

$500,000.00

Public - City

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

Subscribe For Documents

No Data

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
581
Active Projects
237
Bidding Soon
3,750
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

November 19, 2026

December 21, 2026

Project location map

365 Quaker Meetinghouse Rd, E Sandwich, MA


Recently Viewed

Get Started

Unlock the Full Project List

Access every active project near you — get started today.

  • 825,000+ active commercial projects tracked daily
  • Verified contact info for the GC, owner, and architect
  • New leads delivered to your inbox every morning
Get Access

Create your account to get started.

Takes less than a minute — no credit card needed