Renovation of a residential development in West Brookfield, Massachusetts. Completed plans call for the renovation of a residential development.

Removal of existing fire alarm system and installation of new addressable fire alarm control panel and devices. Final completion within 120 consecutive calendar days. Contractor Qualification DCAMM Certificate Required for DCAMM contracts over $150,000, Highway Division contracts over $50,000. 1.1 DESCRIPTION: A. West Brookfield Housing Authority - Olde Village Place (667-1) 1. The scope of work at this site includes the furnishing, installation, connection and testing of the microprocessor controlled, intelligent reporting fire alarm equipment required to form a complete, operative, coordinated system. It shall include, but not be limited to, alarm initiating devices, alarm notification appliances, Fire Alarm Control Panel (FACP), auxiliary control devices, annunciators, and wiring as shown on the drawings and specified herein. The new system will be connected to the existing telephone line. B. The fire alarm system shall comply with requirements of NFPA Standard 72 for Protected Premises Signaling Systems except as modified and supplemented by this specification. The system shall be electrically supervised and monitor the integrity of all conductors. C. The fire alarm system shall be manufactured by an ISO 9001 certified company and meet the requirements of BS EN9001: ANSI/ASQC Q9001-1994. D. The system and its components shall be Underwriters Laboratories, Inc. listed under the appropriate UL testing standard as listed herein for fire alarm applications and the installation shall be in compliance with the UL listing. 1.2. SCOPE: A. A new intelligent reporting, microprocessor controlled fire detection system shall be installed in accordance to the project specifications and drawings. B. Basic Performance: 1. Alarm, trouble and supervisory signals from all intelligent reporting devices shall be encoded on NFPA Style 4 (Class B) Signaling Line Circuits (SLC). 2. Initiation Device Circuits (IDC) shall be wired Class B (NFPA Style A) as part of an addressable device connected by the SLC Circuit. 3. Notification Appliance Circuits (NAC) shall be wired Class B (NFPA Style Y) as part of an addressable device connected by the SLC Circuit. 4. On Style 6 or 7 (Class A) configurations a single ground fault or open circuit on the system Signaling Line Circuit shall not cause system malfunction, loss of operating power or the ability to report an alarm. 5. Alarm signals arriving at the FACP shall not be lost following a primary power failure (or outage) until the alarm signal is processed and recorded. C. BASIC SYSTEM FUNCTIONAL OPERATION When a fire alarm condition is detected and reported by one of the system initiating devices, the following functions shall immediately occur: 1. The system alarm LED on the system display shall flash. 2. A local piezo electric signal in the control panel shall sound. 3. A backlit LCD display shall indicate all information associated with the fire alarm condition, including the type of alarm point and its location within the protected premises. 4. Printing and history storage equipment shall log the information associated each new fire alarm control panel condition, along with time and date of occurrence. 5. All system output programs assigned via control-by-event interlock programming to be activated by the particular point in alarm shall be executed, and the associated system outputs (notification appliances and/or relays) shall be activated. Question Deadline 05/08/2025 at 5:00 PM ET All bidding Requests for Information (RFIs) shall be submitted online

Award

Residential Subdivision

$254,980.00

Public - City

Renovation

12

10

4

3

Subscribe For Documents

13 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
616
Active Projects
221
Bidding Soon
4,786
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

May 14, 2025

June 13, 2025

Project location map

29 E Main St, West Brookfield, MA

Related To This Project


Recently Viewed

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.