Privately Funded
Bidding Soon
Documents Available
Publicly Funded
Addenda Available
Post-Bid
Published August 22, 2025 at 8:00 PM
Updated August 23, 2025
Renovation of a mixed-use development in Lexington, Virginia. Completed plans call for the renovation of a educational facility; and military facility.
Steam Line repairs/replacement in mechanical room, scope of work and schematic attached. Pricing to include materials, labor and freight if applicable. Optional Pre-bid Meeting information included in attachment. Demolition - Contractor shall demolish existing heat exchanger, mounting brackets, and steam supply piping back to the marked location, being careful to save the exist control valve and Spence PRV for re-use. They shall also demolish the abandoned steam supply piping back to the marked locations and cap the line. The contractor shall also demolish the condensate discharge piping as far as necessary to tie in the new heat exchanger. The contractor shall also demolish the water-side piping back to the marked valves. Construction -The Contractor shall fabricate new mounting brackets or a stand to install a VMI supplied heat exchanger in the approximate location of the old unit. Starting from the limits of demolition, the contractor shall install new piping to a VMI provided Spence PRV, and install a %" tee rj closer than 12" downstream for the pilot valve sensing line. Afterthe PRV, the contractor shall tee the steam supply line to tie in the exist pool heat exchanger. The contractor shall continue running new pipe to the newly installed building heat exchanger, incorporating the existing control valve into the installation. The contractor shall then install new piping to tie in the condensate discharge to the condensate return line using a VMI supplied steam trap. Last, the contractor shall supply new butterfly valves to connect the heat exchanger to the water supply and return lines. Acceptable piping for this application is SCH40 steel pipe with threaded connection. The contractor may substitute welded joints for threaded. Unions shall be installed before and after the PRV, control valve, steam trap, and on the water supply and return lines. All newly installed steel pipe and fittings shall be coated with high temperature paint. All newly installed pipe and existing pipe that has been identified by VMI shall be insulated. The contractor shall install sufficient pipe support for all new piping.
Award
Military
$12,984.00
Public - State/Provincial
Renovation
Trades Specified
Division 00 - Lorem Ipsum
One Low Price
- One license and one market
- Details and key contacts on all bidding projects
- Organize your pipeline with a digital bid board
- Automatically match opportunities to your profile
- Saved searches deliver daily project leads to your email inbox
Market Pricing Around
- All Starter Product functionality
- Access to all documents (plans, specifications, and addenda)
- Access to planning projects
- Access to contact information
- Ability to Export
Find More Local Projects
Within 75 Miles of This Project
You’ve Reached the Free View Limit
Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.
Come back in [[refresh_days]] to get [[project_count]] more free projects.
August 19, 2025
September 18, 2025
319 Letcher Ave, Lexington, VA
Related To This Project
Lexington, VA
--
Lexington, VA
Bid Date: Feb 15 2026
Lexington, VA
Bid Date: Sep 08 2025
Lexington, VA
Bid Date: Sep 23 2025
Lexington, VA
Bid Date: Nov 03 2025
Lexington, VA
Bid Date: Aug 27 2025
Lexington, VA
Bid Date: Jul 09 2025
Lexington, VA
Bid Date: Jul 10 2025
Lexington, VA
Bid Date: Jul 15 2025
Lexington, VA
Bid Date: Sep 26 2025
Lexington, VA
Bid Date: Apr 30 2025
Lexington, VA
--
Preview Active Commercial Construction Projects Like This One