BLOCK PAGE!!!
Get Full Details

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Published December 4, 2025 at 7:00 PM

Updated December 5, 2025

Renovation of a mixed-use development in Baltimore, Maryland. Completed plans call for the renovation of a medical facility.

512-26-1-444-0006, 512-25-052 The contractor shall provide all materials, labor, equipment, and supervision required to complete the LR Building 6 Boiler Replacement Project at the VA Maryland Health Care System, Loch Raven Campus. Work includes removing the existing Weil McClain Water Tube Boiler rated at 209 MBH from the Building 6 mechanical room and properly disposing of it, with disposal receipts submitted to the VA. A new CSD-1 compliant boiler, sized to match the existing unit, will be installed on the current equipment pad. Existing utility lines should be utilized for tie-ins where feasible, except for the vent line, which must be replaced with PVC per NBCI code due to deterioration of the atmospheric metal duct. The contractor will confirm tie-in feasibility and vent line replacement during the pre-bid walkthrough and make minor modifications as needed to fit the new boiler. Installation must follow the boiler manufacturer's instructions and comply with all local, state, federal, and VA specifications and guidelines. Materials must meet ICRA safety requirements. The contractor will provide warranty and start-up services to ensure proper operation of the new boiler. All work must be completed within 30 calendar days from the Notice to Proceed. Questions and site visit requests due: 11/24/25 Formal Quotes due: 12/03/25 Contracting POC: William.Galletta@va.gov Address: 3901 Loch Raven Blvd, Baltimore, MD 21218, Address: 10 N Greene St, Baltimore MD 21201. Remove and dispose of existing Weil McClain Water Tube Boiler (209MBH). Provide disposal receipts to VA. Provide and install CSD-1 compliant Boiler sized to match existing boiler. Utilize existing utility lines for tie-ins where possible except for the vent line. New PVC vent line must be installed.

Post-Bid

Medical

$300,000.00

Public - Federal

Renovation

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

5

Subscribe For Documents

34 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
550
Active Projects
228
Bidding Soon
3,657
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

December 3, 2025

December 8, 2025

Project location map

Multiple Locations, Baltimore, MD

Related To This Project


Recently Viewed

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.