BLOCK PAGE!!!
Get Full Details

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Published June 9, 2025 at 8:00 PM

Updated June 10, 2025

Renovation of a military facility in Fresno, California. Completed plans call for the renovation of a military facility.

The Government intends to award a firm fixed price contract from this to replace the Intrusion Detection System Control Panel and associated system components for the Internal Revenue Service at 3211 Northpointe Ave., Fresno, CA in accordance with the attached statement of work (SOW) dated 5/7/2025. There is a visit scheduled for Thursday, May 22nd, 2025 at 10:00am PDT. Please RSVP for the visit with the project manager listed in the . SUBMISSION OF S/ RFIs: s be submitted by May 27th, 2025. Submit all s to the Contracting Officer and Project Manager via . SCOPE OF WORK I. STATEMENT OF WORK This project is to purchase and install a new ethernet capable Intrusion Detection System Control Panel to replace the existing panel. Forty seven (47) existing zone devices (motions, glass breaks, duress and door contacts) will need to be reconnected, programmed and tested 1.0 OVERVIEW Demo existing ADEMCO VISTA 128BP Panel with associated zone expanders, power supplies and keypads and replace with panel below. 47 existing zone devices (Motions, Glass Breaks, Duress and Door Contacts) will remain and need to be reconnected, programmed, and tested to new panel. Install one (1) Intrusion Detection System (IDS) Control Panel (similar to Bosch B8512G or B9512G for more than 99 devices) or approved equal w/ Mega Center data connectivity) Approximate is shown on drawings and be field verified and approved by security specialist. Contractor supply and install all accessories pertaining to each panel. Items be mounted securely and resist tampering. Control panels and accessories shall be tested during inspection. Install (2) alarm keypads [Similar to Bosch B942 touch screen keypads or approved equal] as shown on layout (coordinate locations with Security Specialist). Mount the keypad device(s) at the approximate 54 in. height. NOTE: Keypads will ONLY alarm and/or trouble conditions in plain English and activate an audible alarm so that IRS employees can recognize trouble/alarm and location. The device/descriptions be conveyed to the designated FPS Mega Center. Specific (additional) tasks are as follows: o Contractor shall install all (new) burglar equipment according to manufacturer's specifications. Suggested alarm devices/line modules shall be Belden 8761, 22- gauge (for lengths up to 400 feet) or Belden 8760, 18 gauge for lengths up to 1, 200 feet respectively. o Hardwire the panel OEM supplied transformer box outside and below the control panel with EMT in accordance with the NEC, and UL standards. o Hardwire surge protector ahead of the panel OEM power supply [Ditek DTK-120HW or equal50,000A surge rating, 10kA SCCR/In, 700V L-G/L-N; 1500V N-G;]. o Install the OEM included control panel tamper switch on the control panel to a hardwired panel zone. Program as '24-hour auxiliary' alarm (i.e., to Mega Center). o Install the dual battery harness included with the Burglar panel. Also provide cam lock and key [Medeco Cam Locks or UL434 Listed equal]. o Install two 12-volt, 17 or 18 amp-hour batteries into the Burglar control panel [the 7-amp hour rated unitsis NOT acceptable] Install one RJ15 connector w/ CAT6 cable inside the Burglar control panel to IT provided switch port. o Install two surge protectors [Ditek MRJ45 SCPOPX or equal: RJ4548V ahead of the data lines for the alarm system (i.e., to be eventually linked to the FPS Mega Center). o Install Auxiliary Power Supply [Altronix AL400ULM or approved equal: 5 PTC Class 2 Outputs (autoresettable), 12/24VDC 4A, FAI, 115VAC] (UL Listed Commercial) w/ tamper switch and program for 24-hour auxiliary alarm. Install auxiliary power supply below the control panel connected by EMT. If hardwired to the AC, install a surge protector ahead of the Auxiliary Power Supply line voltage. Use this for detection device and keypad power on non-polling loop powered devices. All wires that come into or out of all panels/enclosures be in EMT or fished in the wall into the back of the enclosures. No exposed and/or visible wires are permitted. o Install one 12-volt, 17-amp hour battery into the Auxiliary Power Supply. Connect Auxiliary Power Supply to the control panel's hardwired panel zones for detection and notification. o Install at least one UL365 listed spare enclosure below the Auxiliary Power Supply connected by EMT or fish the wires in the wall and into the back of the panel. Install a tamper switch on the panel (programmed as 24-hour auxiliary). Provide cam lock(s) and key(s) [Medeco Cam Locks or UL434 Listed equal] for zone expanders and terminal strips. o Install OEM zone expanders as (one minimum) for the number of devices in this scope; inside the spare enclosure mentioned above. A zone per each device is for every device. Each expander will provide 8 zones via zone expanders. Each individual device annunciate locally with its specific and communicate this identification back to the designated FPS Mega Center. In general, install cam locks w/key [Medeco Cam Locks or UL434 Listed equal] & IDS panel OEM tamper switches on all control panels, enclosures, power supplies, etc. Note: all tamper switches be linked to Mega Center for monitoring

Sub-Bidding

Military

$200,000.00

Public - Federal

Renovation

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

8

Subscribe For Documents

2 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
117
Active Projects
52
Bidding Soon
631
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

June 10, 2025

July 10, 2025

Project location map

3211 S Northpointe Dr, Fresno, CA

Related To This Project


Recently Viewed

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.